SearcharxivSearch

arXiv subjects

Manvendra Sharma

Publications and source records attributed to Manvendra Sharma.

4 recordsLinked to original sources

Direct Production of A Hyperpolarized Metabolite on a Microfluidic Chip

Microfluidic systems hold great potential for the study of live microscopic cultures of cells, tissue samples, and small organisms. Integration of hyperpolarisation would enable quantitative studies of metabolism in such volume limited systems by high-resolution NMR spectroscopy. We demonstrate, for the first time, the integrated generation and detection of a hyperpolarised metabolite on a microfluidic chip. The metabolite 1-$^{13}$C-fumarate is produced in a nuclear hyperpolarised form by (i) introducing para-enriched hydrogen into the solution by diffusion through a polymer membrane, (ii) reaction with a substrate in the presence of a ruthenium-based catalyst, and (iii) conversion of the singlet-polarised reaction product into a magnetised form by the application of a radiofrequency pulse sequence, all on the same microfluidic chip. The microfluidic device delivers a continuous flow of hyperpolarised material at the 2.5 $\mu\text{L}/\text{min}$ scale, with a polarisation level of 4%. We demonstrate two methods for mitigating singlet-triplet mixing effects which otherwise reduce the achieved polarisation level.

physics.chem-ph

High-Resolution Nuclear Magnetic Resonance Spectroscopy With Picomole Sensitivity by Hyperpolarisation On A Chip

We show that high-resolution NMR can reach picomole sensitivity for micromolar concentrations of analyte by combining parahydrogen induced hyperpolarisation (PHIP)with a high-sensitivity transmission line micro-detector. The para-enriched hydrogen gas is introduced into solution by diffusion through a membrane integrated into a microfluidic chip. NMR microdetectors, operating with sample volumes of a few $μ$L or less, benefit from a favourable scaling of mass sensitivity. However, the small volumes make it very difficult to detect species present at less than millimolar concentrations in microfluidic NMR systems. In view of overcoming this limitation, we implement parahydrogen-induced polarisation (PHIP) on a microfluidic device with 2.5~$\mathrm{μL}$ detection volume. Integrating the hydrogenation reaction into the chip minimises polarisation losses to spin-lattice relaxation, allowing the detection of picomoles of substance. This corresponds to a concentration limit of detection of better than $\mathrm{1\,μM\,\sqrt{s}}$, unprecedented at this sample volume. The stability and sensitivity of the system allows quantitative characterisation of the signal dependence on flow rates and other reaction parameters and permits homo- and heteronuclear 2D NMR experiments at natural $^{13}\mathrm{C}$ abundance.

physics.chem-ph

Modular transmission line probes for microfluidic nuclear magnetic resonance spectroscopy and imaging

Microfluidic NMR spectroscopy can probe chemical and bio-chemical processes non-invasively in a tightly controlled environment. We present a dual-channel modular probe assembly for high efficiency microfluidic NMR spectroscopy and imaging. It is compatible with a wide range of microfluidic devices, without constraining the fluidic design. It collects NMR signals from a designated sample volume on the device with high sensitivity and resolution. Modular design allows adapting the detector geometry to different experimental conditions with minimal cost, by using the same probe base. The complete probe can be built from easily available parts. The probe body mainly consists of prefabricated aluminium profiles, while the probe circuit and detector are made from printed circuit boards. We demonstrate a double resonance HX probe with a limit of detection of 1.4 nmol s$^{1/2}$ for protons at 600~MHz, resolution of 3.35 Hz, and excellent B$_{1}$ homogeneity. We have successfully acquired $^1$H-$^{13}$C and $^{1}$H-$^{15}$N heteronuclear correlation spectra (HSQC), including a $^{1}$H-$^{15}$N HSQC spectrum of 1 mM $^{15}$N labeled ubiquitin in 2.5 $μ$l of sample volume.

physics.ins-det

Measurement of Translational Diffusion Constant using Noon State

A method for measuring translational diffusion constant in liquids via NOON state is described using a quantum circuit and is experimentally demonstrated using a model system. When compared with the standard single quantum method, the NOON state method requirs shorter diffusion delays and weaker gradients. These improvements depend on the on the size of the NOON state. Due to the high sensitivity of the NOON state for the changes in the local magnetic fields, this method enables studying slow diffusion and studying diffusion with limited strengths of pulsed-field-gradients.

quant-ph