SearcharxivSearch

arXiv subjects

Manzhou Zhang

Publications and source records attributed to Manzhou Zhang.

5 recordsLinked to original sources

Robust Betatron-Tune Measurement from Schottky Spectra: Complementary Classical and Deep-Learning Paradigms

Schottky spectra provide key beam diagnostics, with betatron sidebands encoding the fractional tune. Reliable tune measurement is particularly important for third-order resonance slow extraction in compact medical proton synchrotrons, where low signal-to-noise ratios and limited frequency resolution can compromise conventional peak-detection and curve-fitting methods. This work develops two complementary tune estimators with a shared spectral front-end but different temporal representations. The classical estimator coherently pools motion-compensated spectra, detects the sideband using a multi-width matched-filter bank, and performs sub-bin estimation through local argmax and an adaptive MAD-gated centroid. The deep-learning estimator converts each spectrum into a tune-likelihood map using a convolutional neural network with FFT-based global convolutions, then propagates the posterior with a discrete two-dimensional (q,v) Bayesian tracker under a Gaussian motion model while also reporting posterior uncertainty. On a synthetic dynamic-tune benchmark, the deep-learning estimator outperforms published baselines across the operating range, while the classical estimator exceeds the latency-compensated baseline and requires neither training data nor GPU acceleration. On near-stationary SAPT beam data, both methods operate end-to-end, with the deep-learning model requiring no retraining. Median per-frame latency remains below 1 ms on commodity hardware, supporting real-time-capable tune measurement in compact medical synchrotrons.

physics.acc-ph

Real-Time-Capable Betatron Tune Measurement from Schottky Spectra Using Deep Learning and Uncertainty-Aware Kalman Filtering

Betatron tune measurement is essential for beam control in compact proton-therapy synchrotrons, yet conventional peak-detection techniques are not robust under the low signal-to-noise ratio (SNR) conditions typical of these machines. This work presents a lightweight convolutional neural network that performs real-time tune extraction from Schottky spectra with sub-millisecond inference latency and calibrated uncertainty estimates. The model uses attention-based pooling for reliable peak localization and a dual-branch architecture that jointly predicts the tune and its associated uncertainty. Trained with a Laplace negative log-likelihood loss, it produces uncertainty estimates whose magnitude tracks the instantaneous prediction error, which enables uncertainty-aware Kalman filtering for temporal smoothing. Experiments on a large synthetic dataset spanning SNR levels from 0 to $-20$\,dB demonstrate substantial performance gains over traditional peak-detection baselines, while the Kalman filter further suppresses transient outliers in time-series operation. Preliminary validation on operational beam data confirms stable tune tracking without retraining. With only about $2.0\times 10^{4}$ trainable parameters and real-time inference on commodity GPU hardware, the proposed diagnostic offers a practical solution for rapid and accurate betatron tune monitoring in compact medical synchrotrons and similar accelerators.

physics.acc-ph

High-Accuracy Schottky Diagnostics for Low-SNR Betatron Tune Measurement in Ramping Synchrotrons

This study introduces a novel real-time betatron tune measurement algorithm, utilizing Schottky signals and an FPGA-based backend architecture, specifically designed for rapidly ramping synchrotrons, with particular application to the Shanghai Advanced Proton Therapy (SAPT) facility. The developed algorithm demonstrates improved measurement accuracy under challenging operational conditions, especially in scenarios with limited sampling time and signal-to-noise ratios (SNR) as low as \(-20\) dB. By applying Short-Time Fourier Transform (STFT) analysis, the algorithm effectively accommodates the rapid increase in revolution frequency from 4 MHz to 7.5 MHz over 0.35 seconds, along with tune shifts. A macro-particle simulation methodology is employed to generate Schottky signals, which are then combined with real noise collected from an analog-to-digital converter (ADC) to simulate practical conditions. The proposed betatron tune measurement algorithm integrates advanced spectral processing techniques and an enhanced peak detection algorithm specifically tailored for low SNR conditions. Experimental validation confirms the superior performance of the proposed algorithm over conventional approaches in terms of measurement accuracy, stability, and system robustness, while meeting the stringent operational requirements of proton therapy applications. This innovative approach effectively addresses critical limitations associated with Schottky diagnostics for betatron tune measurement in rapidly ramping synchrotrons operating under low SNR conditions, laying a robust foundation and providing a viable solution for advanced applications in proton therapy and related accelerator physics fields.

physics.acc-ph

Multi-bunch injection for SSRF storage ring

The multi-bunch injection has been adopt at SSRF which greatly increases the injection rate and reduces injection time compared to the single bunch injection. The multi-bunch injection will massively reduce the beam failure time during users operation and prolong pulsed injection hardware lifetime. In this paper, the scheme to produce multi bunches for the RF electron gun is described. The refilling result and the beam orbit stability for top up operation is discussed.

physics.acc-ph

Coherent photon beam based diagnostics for a seeded extreme ultraviolet free-electron laser

Independently from electron beam based procedures, photon beam based diagnostics is an alternative way for alignment and commissioning of the numerous undulator cells in a high-gain short-wavelength free-electron laser (FEL). In this paper, using the seed laser modulated electron beam and the undulator fine tuning technique, a coherent photon beam based diagnostic was proposed for seeded FEL, and some preliminary experimental results at Shanghai deep ultraviolet FEL test facility were presented. It demonstrates that the spatial distribution of the coherent harmonic radiation from one individual or two consecutive undulator segments can be used to optimize the electron beam trajectory, to verify the undulator magnetic gap, and to adjust the phase match between two undulator segments.

physics.acc-ph