SearcharxivSearch

arXiv subjects

Marc Eisenmann

Publications and source records attributed to Marc Eisenmann.

7 recordsLinked to original sources

Quantum noise reduction schemes for KAGRA post-O5 upgrade

Quantum noise, arising from the quantisation of electromagnetic field, has been a limiting noise source for current gravitational wave (GW) detectors. Squeezed vacuum modifies quantum fluctuations and has been routinely employed. To reduce quantum noise, the current solution is to combine squeezed vacuum with a detuned over-coupled optical cavity (filter cavity) to achieve frequency-dependent squeezing (FDS). The sensitivity to GW signals can be decomposed into a noise budget. Depending on the detector configuration, the contribution from noise sources other than quantum noise can be significant. In particular, suspension noise from multi-stage pendulums is a key factor in quantum-noise reduction design. In the context of KAGRA post-O5, we have compared quantum noise reduction schemes, frequency-independent squeezing (FIS), FDS with a filter cavity (FC), FDS with an amplitude filter cavity (AFC), FDS with a frequency-dependent beam splitter (FDBS) and EPR scheme. The FC scheme was found to outperform the AFC and FDBS schemes at all frequencies. It was found that FIS scheme gives the largest Binary Neutron Star (BNS) range when low frequency noise is dominated by classical noise, while the FC scheme gives the largest BNS range when low-frequency noise becomes dominated by quantum noise. Optimised filter cavity parameters could substantially improve the BNS range. This would allow at least 23% increase in the detection rate for an 85 m filter cavity, compared with using FIS scheme. Once a filter cavity is constructed with optimised parameters, refining its detuning can fully compensate for the variations in arm power (from half to full design value) and for different intra-cavity loss conditions. The EPR scheme performs best for the detection of heavy binary systems.

hep-ex

Demonstration of length control for a filter cavity with coherent control sidebands

For broadband quantum noise reduction of gravitational-wave detectors, a frequency-dependent squeezed vacuum field realized using a filter cavity is the most promising technique and will be implemented in Advanced LIGO and Advanced Virgo in the fourth observing run. To obtain the benefit of frequency-dependent squeezing, the length and alignment of the filter cavity with respect to the squeezed vacuum field must be accurately controlled. To this purpose, a new length and alignment control scheme for a filter cavity, using coherent control sidebands, was suggested [Phys. Rev. D 102, 042003 (2020)]. The coherent control sidebands are already used to control the squeezing angle in squeezed vacuum sources for gravitational-wave detectors. As both the squeezed vacuum field and coherent control sidebands have the same mode-matching conditions and almost the same frequency, the length and alignment of the filter cavity with respect to the squeezed vacuum field can be accurately controlled with this scheme. In this paper, we experimentally demonstrate the new control scheme for a filter cavity with coherent control sidebands. In addition to the conventional filter cavity control with the green field, we succeed in controlling the length of a 300-m filter cavity with coherent control sidebands and reduce the filter cavity length noise (rms) from 6.8 to 2.1 pm.

physics.ins-det

A Polarization-Decomposed Method for Simulating Inhomogeneous Birefringence in Laser-Interferometric Gravitational-Wave Detectors

Birefringence in test mass substrates is an emerging limitation for current and future laser-interferometric gravitational-wave detectors, particularly as detectors move toward higher circulating power, cryogenic operation, and crystalline optical materials. Spatially varying birefringence alters both the polarization state and spatial mode content of the intracavity field, reducing interference contrast and coupling into length and alignment control signals. Accurate modeling of these effects is complicated by the fact that most frequency-domain simulation tools employ scalar modal propagation and lack native support for polarization and two-dimensional substrate maps. In this work, we present a practical and general method for simulating inhomogeneous birefringence without modifying existing simulation frameworks. The approach represents the two polarization components as independent scalar fields and introduces their coupling through an equivalent triple-Mach-Zehnder construction that reproduces the Jones matrix of a birefringent medium. We demonstrate the method using realistic birefringence maps of the KAGRA sapphire input test masses. The technique is compatible with any frequency-domain interferometer model and enables efficient birefringence studies for next-generation gravitational-wave detectors.

physics.ins-det

Characterisation of birefringence inhomogeneity of KAGRA sapphire mirrors from transmitted wavefront error measurements

Cooling down test masses to cryogenic temperatures is a way to reduce the thermal noise of gravitational wave detectors. Crystalline materials are considered the most promising materials for fabricating cryogenic test masses and their coatings because of their excellent thermal and optical properties at low temperatures. However, birefringence owing to local impurities and inhomogeneities in the crystal can degrade the performance of the detector. The birefringence measurement or mapping over a two-dimensional area is thus important. This study describes a method for fast birefringence measurements of a large sample by simply combining a series of transmission wavefront error measurements using linearly polarised light with Fizeau interferometers. Using this method, the birefringence inhomogeneity information of KAGRA's two input test masses with a diameter of 22 cm was fully reconstructed. The birefringence information was then used to calculate the transverse beam shapes of the light fields in orthogonal polarisation directions when passing through the substrate. It was possible to find a calculated beam shape consistent with in-situ measurements using the KAGRA interferometer. This technique is crucial for birefringence characterisation of test masses in future detectors, where even larger sizes are used.

physics.optics

Improving the stability of frequency dependent squeezing with bichromatic control of filter cavity length, alignment and incident beam pointing

Frequency dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency dependence of the squeezed quadrature is obtained by reflecting squeezed vacuum from a Fabry-Perot filter cavity detuned by half of its linewidth. However, since the squeezed vacuum contains no classical amplitude, co-propagating auxiliary control beams are required to achieve the filter cavity's length, alignment, and incident beam pointing stability. In our frequency dependent squeezing experiment at the National Astronomical Observatory of Japan, we used a control beam at a harmonic of squeezed vacuum wavelength and found visible detuning variation related to the suspended mirrors angular drift. These variations can degrade interferometer quantum noise reduction. We investigated various mechanisms that can cause the filter cavity detuning variation. The detuning drift is found to be mitigated sufficiently by fixing the incident beam pointing and applying filter cavity automatic alignment. It was also found that there is an optimal position of the beam on the filter cavity mirror that helps to reduce the detuning fluctuations. Here we report a stabilized filter cavity detuning variation of less than 10$\,$Hz compared to the 113$\,$Hz cavity linewidth. Compared to previously published results [Phys. Rev. Lett. 124, 171101 (2020)], such detuning stability would be sufficient to make filter cavity detuning drift induced gravitational wave detector detection range fluctuation reduce from $11\%$ to within $2\%$.

physics.ins-det

Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave Detectors

The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.

astro-ph.IM

Measurement of optical losses in a high-finesse 300 m filter cavity for broadband quantum noise reduction in gravitational-wave detectors

Earth-based gravitational-wave detectors will be limited by quantum noise in a large part of their spectrum. The most promising technique to achieve a broadband reduction of such noise is the injection of a frequency dependent squeezed vacuum state from the output port of the detector, whit the squeeze angle rotated by the reflection off a Fabry-Perot filter cavity. One of the most important parameters limiting the squeezing performance is represented by the optical losses of the filter cavity. We report here the operation of a 300 m filter cavity prototype installed at the National Astronomical Observatory of Japan (NAOJ). The cavity is designed to obtain a rotation of the squeeze angle below 100 Hz. After achieving the resonance of the cavity with a multi-wavelength technique, the round trip losses have been measured to be between 50 ppm and 90 ppm. This result demonstrates that with realistic assumption on the input squeeze factor and on the other optical losses, a quantum noise reduction of at least 4 dB in the frequency region dominated by radiation pressure can be achieved.

astro-ph.IM