SearcharxivSearch

arXiv subjects

Marcel Utz

Publications and source records attributed to Marcel Utz.

8 recordsLinked to original sources

Chemical hydrodynamics of nuclear spin states

Quantum mechanical equations of motion are strictly linear in state descriptors, such as wavefunctions and density matrices, but equations describing chemical kinetics and hydrodynamics may be non-linear in concentrations. This incompatibility is fundamental, but special cases can be handled - for example, in magnetic resonance where nuclear spin interactions may be too weak influence concentration dynamics. For processes involving single spins and first-order chemical reactions, this is a well-researched topic, but time evolution of complex nuclear spin systems in the presence of second-order kinetics, diffusion, and flow has so far remained intractable. This creates obstacles in microfluidics, homogeneous catalysis, and magnetic resonance imaging of metabolic processes. In this communication we report a numerically stable formalism for time-domain quantum mechanical description of nuclear spin dynamics and decoherence in the simultaneous presence of diffusion, flow, and second-order chemical reactions. The formalism is implemented in versions 2.11 and later of the open-source Spinach library. As an illustration, we use Diels-Alder cycloaddition of acrylonitrile to cyclopentadiene, yielding endo- and exo-norbornene carbonitrile, in the presence of diffusion and flow in the detection chamber of a microfluidic NMR probe (a finite element model with thousands of Voronoi cells) with a spatially localised stripline radiofrequency coil.

physics.chem-ph

Metabolic Reactions Studied by Zero- and Low-Field Nuclear Magnetic Resonance

State-of-the-art magnetic resonance imaging uses hyperpolarized molecules to track metabolism in vivo, but large superconducting magnets are required, and the strong magnetic fields largely preclude measurement in the presence of conductive materials and magnify problems of magnetic susceptibility inhomogeneity. Operating at zero and low field circumvents these limitations, but until now has not been possible due to limited sensitivity. We show that zero- and low-field nuclear magnetic resonance can be used for probing two important metabolic reactions: the conversion of hyperpolarized fumarate to malate and pyruvate to lactate. This work paves the way to a heretofore unexplored class of biomedical imaging applications.

physics.chem-ph

Direct Production of A Hyperpolarized Metabolite on a Microfluidic Chip

Microfluidic systems hold great potential for the study of live microscopic cultures of cells, tissue samples, and small organisms. Integration of hyperpolarisation would enable quantitative studies of metabolism in such volume limited systems by high-resolution NMR spectroscopy. We demonstrate, for the first time, the integrated generation and detection of a hyperpolarised metabolite on a microfluidic chip. The metabolite 1-$^{13}$C-fumarate is produced in a nuclear hyperpolarised form by (i) introducing para-enriched hydrogen into the solution by diffusion through a polymer membrane, (ii) reaction with a substrate in the presence of a ruthenium-based catalyst, and (iii) conversion of the singlet-polarised reaction product into a magnetised form by the application of a radiofrequency pulse sequence, all on the same microfluidic chip. The microfluidic device delivers a continuous flow of hyperpolarised material at the 2.5 $\mu\text{L}/\text{min}$ scale, with a polarisation level of 4%. We demonstrate two methods for mitigating singlet-triplet mixing effects which otherwise reduce the achieved polarisation level.

physics.chem-ph

Synergies between Hyperpolarized NMR and Microfluidics: A Review

Hyperpolarized nuclear magnetic resonance and lab-on-a-chip microfluidics are two dynamic, but until recently quite distinct, fields of research. Recent developments in both areas increased their synergistic overlap. By microfluidic integration, many complex experimental steps can be brought together onto a single platform. Microfluidic devices are therefore increasingly finding applications in medical diagnostics, forensic analysis, and biomedical research. In particular, they provide novel and powerful ways to culture cells, cell aggregates, and even functional models of entire organs. Nuclear magnetic resonance is a non-invasive, high-resolution spectroscopic technique which allows real-time process monitoring with chemical specificity. It is ideally suited for observing metabolic and other biological and chemical processes in microfluidic systems. However, its intrinsically low sensitivity has limited its application. Recent advances in nuclear hyperpolarization techniques may change this: under special circumstances, it is possible to enhance NMR signals by up to 5 orders of magnitude, which dramatically extends the utility of NMR in the context of microfluidic systems. At the same time, hyperpolarization requires complex chemical and/or physical manipulations, which in turn may benefit from microfluidic implementation. In fact, many hyperpolarization methodologies rely on processes that are more efficient at the micro-scale, such as molecular diffusion, penetration electromagnetic radiation into the sample, or restricted molecular mobility on a surface. In this review we examine the confluence between the fields of hyperpolarization-enhanced NMR and microfluidics, and assess how these areas of research have mutually benefited one another, and will continue to do so.

physics.chem-ph

Modular transmission line probes for microfluidic nuclear magnetic resonance spectroscopy and imaging

Microfluidic NMR spectroscopy can probe chemical and bio-chemical processes non-invasively in a tightly controlled environment. We present a dual-channel modular probe assembly for high efficiency microfluidic NMR spectroscopy and imaging. It is compatible with a wide range of microfluidic devices, without constraining the fluidic design. It collects NMR signals from a designated sample volume on the device with high sensitivity and resolution. Modular design allows adapting the detector geometry to different experimental conditions with minimal cost, by using the same probe base. The complete probe can be built from easily available parts. The probe body mainly consists of prefabricated aluminium profiles, while the probe circuit and detector are made from printed circuit boards. We demonstrate a double resonance HX probe with a limit of detection of 1.4 nmol s$^{1/2}$ for protons at 600~MHz, resolution of 3.35 Hz, and excellent B$_{1}$ homogeneity. We have successfully acquired $^1$H-$^{13}$C and $^{1}$H-$^{15}$N heteronuclear correlation spectra (HSQC), including a $^{1}$H-$^{15}$N HSQC spectrum of 1 mM $^{15}$N labeled ubiquitin in 2.5 $\mu$l of sample volume.

physics.ins-det

High-Resolution Nuclear Magnetic Resonance Spectroscopy With Picomole Sensitivity by Hyperpolarisation On A Chip

We show that high-resolution NMR can reach picomole sensitivity for micromolar concentrations of analyte by combining parahydrogen induced hyperpolarisation (PHIP)with a high-sensitivity transmission line micro-detector. The para-enriched hydrogen gas is introduced into solution by diffusion through a membrane integrated into a microfluidic chip. NMR microdetectors, operating with sample volumes of a few $\mu$L or less, benefit from a favourable scaling of mass sensitivity. However, the small volumes make it very difficult to detect species present at less than millimolar concentrations in microfluidic NMR systems. In view of overcoming this limitation, we implement parahydrogen-induced polarisation (PHIP) on a microfluidic device with 2.5~$\mathrm{\mu L}$ detection volume. Integrating the hydrogenation reaction into the chip minimises polarisation losses to spin-lattice relaxation, allowing the detection of picomoles of substance. This corresponds to a concentration limit of detection of better than $\mathrm{1\,\mu M\,\sqrt{s}}$, unprecedented at this sample volume. The stability and sensitivity of the system allows quantitative characterisation of the signal dependence on flow rates and other reaction parameters and permits homo- and heteronuclear 2D NMR experiments at natural $^{13}\mathrm{C}$ abundance.

physics.chem-ph

Extended Wigner function formalism for the spatial propagation of particles with internal degrees of freedom

An extended Wigner function formalism is introduced for describing the quantum dynamics of particles with internal degrees of freedom in the presence of spatially inhomogeneous fields. The approach is used for quantitative simulations of molecular beam experiments involving space-spin entanglement, such as the Stern-Gerlach and the Rabi experiment. The formalism allows a graphical visualization of entanglement and decoherence processes.

quant-ph