SearcharxivSearch

arXiv subjects

Marcelo Elizondo

Publications and source records attributed to Marcelo Elizondo.

11 recordsLinked to original sources

Policy Gradient-Based EMT-in-the-Loop Learning to Mitigate Sub-Synchronous Control Interactions

This paper explores the development of learning-based tunable control gains using EMT-in-the-loop simulation framework (e.g., PSCAD interfaced with Python-based learning modules) to address critical sub-synchronous oscillations. Since sub-synchronous control interactions (SSCI) arise from the mis-tuning of control gains under specific grid configurations, effective mitigation strategies require adaptive re-tuning of these gains. Such adaptiveness can be achieved by employing a closed-loop, learning-based framework that considers the grid conditions responsible for such sub-synchronous oscillations. This paper addresses this need by adopting methodologies inspired by Markov decision process (MDP) based reinforcement learning (RL), with a particular emphasis on simpler deep policy gradient methods with additional SSCI-specific signal processing modules such as down-sampling, bandpass filtering, and oscillation energy dependent reward computations. Our experimentation in a real-world event setting demonstrates that the deep policy gradient based trained policy can adaptively compute gain settings in response to varying grid conditions and optimally suppress control interaction-induced oscillations.

eess.SY

Oscillation Analysis and Damping Control for a Proposed North American AC-DC Macrogrid

In recent years, several studies conducted by both industry and U.S. Department of Energy (DOE)-funded initiatives have proposed linking North America's Eastern and Western Interconnections (EI and WI) through a multiterminal DC (MTDC) macrogrid. These studies have explored the advantages and opportunities of the proposed configuration from the perspectives of capacity sharing and frequency support. However, the potential challenges of small-signal stability arising from this interconnection have not been thoroughly examined. To address this gap, detailed model-based simulation studies are performed in this paper to assess the risks of poorly damped inter-area oscillations in the proposed macrogrid. A custom-built dynamic model of the MTDC system is developed and integrated with industry-grade models of the EI and WI, incorporating high levels of inverter-based energy resources. Through model-based oscillation analysis, potential shifts in inter-area modes for both EI and WI, resulting from the MTDC integration are characterized, and modes with inadequate damping are identified. Furthermore, to mitigate the risks of unstable oscillations, supplementary damping controllers are designed for the MTDC system, leveraging wide-area feedback to modulate active power set points at selected converter stations. A frequency scanning approach is employed for data-driven model linearization and controller synthesis. The damping performance is evaluated under the designed operating conditions and selected contingency scenarios.

eess.SY

Identification of Sub/Super-Synchronous Control Interaction Paths Using Dissipative Energy Flow

Sub- and super-synchronous control interactions (SSCIs) are oscillations arising from adverse interactions between inverter-based resource (IBR) controls and the power network. SSCIs often involve multiple frequencies and propagate through complex, interconnected paths, making it difficult for model-based approaches to identify both the sources and the paths of oscillatory energy flow. This paper extends the Dissipative Energy Flow (DEF) method, originally developed for low-frequency electromechanical oscillations, to identify SSCI sources and dynamic interaction paths across multiple frequencies using three-phase voltage and current measurements. The approach operates in the dq frame using dynamic phasors, enabling mode-specific DEF computation from bandpass-filtered signals. An electromagnetic transient (EMT) case study on a meshed network with synchronous generator and type-3 wind farm resources under series-compensated conditions demonstrates the method's capability to distinguish frequency-dependent source and sink roles, including cases where the same resource acts as a source at one frequency and a sink at another. The results show DEF can provide a physics-based and automation-friendly tool for SSCI diagnosis in IBR-rich grids.

eess.SY

Physics-Informed Learning of Proprietary Inverter Models for Grid Dynamic Studies

This letter develops a novel physics-informed neural ordinary differential equations-based framework to emulate the proprietary dynamics of the inverters -- essential for improved accuracy in grid dynamic simulations. In current industry practice, the original equipment manufacturers (OEMs) often do not disclose the exact internal controls and parameters of the inverters, posing significant challenges in performing accurate dynamic simulations and other relevant studies, such as gain tunings for stability analysis and controls. To address this, we propose a Physics-Informed Latent Neural ODE Model (PI-LNM) that integrates system physics with neural learning layers to capture the unmodeled behaviors of proprietary units. The proposed method is validated using a grid-forming inverter (GFM) case study, demonstrating improved dynamic simulation accuracy over approaches that rely solely on data-driven learning without physics-based guidance.

eess.SY

Configuration and EMT Simulation of the 240-bus MiniWECC System Integrating Offshore Wind Farms (OWFs)

As offshore wind farms (OWFs) become increasingly prevalent in Northern California and Southern Oregon, they introduce faster dynamics into the Western Electricity Coordinating Council (WECC) system, reshaping its dynamic behavior. Accordingly, electromagnetic transient (EMT) simulation is essential to assess high frequency dynamics of the WECC system with integrated OWFs. Against this background, this paper presents the integration of detailed dynamic models of OWFs into a 240-bus miniWECC system in PSCAD software. The sequential initialization technique is employed to facilitate the smooth initiation of a large-scale system in an EMT simulation. The performance of the configured model is assessed under wind speed variations and grounded faults, demonstrating the effectiveness of the miniWECC system with OWFs. This system serves as a valuable basic use case for validating the fast dynamic performance of future WECC systems with high penetration of wind energy.

eess.SY

Structural Impact of Grid-Forming Inverters on Power System Coherency

This paper addresses the following fundamental research question: how does the integration of grid-forming inverters (GFMs) replacing conventional synchronous generators (SGs) impact the slow coherent eigen-structure and the low-frequency oscillatory behavior of future power systems? Due to time-scale separated dynamics, generator states inside a coherent area synchronize over a fast time-scale due to stronger coupling, while the areas themselves synchronize over a slower time scale. Our mathematical analysis shows that due to the large-scale integration of GFMs, the weighted Laplacian structure of the frequency dynamics is preserved, however, the entries of the Laplacian may be significantly modified based on the location and penetration levels of the GFMs. This can impact and potentially significantly alter the coherency structure of the system. We have validated our findings with numerical results using the IEEE 68-bus test system.

eess.SY

Smart Data Mapping for Connecting Power System Model and Geospatial Data

Knowing the geospatial locations of power system model elements and linking load models with end users and their communities are the foundation for analyzing system resilience and vulnerability to natural hazards. However, power system models and geospatial data for power grid assets are often developed asynchronously without close coordination. Creating a direct mapping between the two is a challenging task, mainly due to heterogeneous data structures, target uses, historical legacies, and human errors. This work aims to build an automatic data mapping workflow to connect the two, and to support energy grid resilience studies for Puerto Rico. The primary steps in this workflow include constructing graphs using geospatial data, and aligning them to the transmission networks defined in the power system data. The results have been evaluated against existing manual mapping practices for part of the Puerto Rico Power Grid model to illustrate the performance of such auto-mapping solutions.

eess.SY

Proactive Posturing of Large Power Grid for Mitigating Hurricane Impacts

In the past decade, natural disasters such as hurricanes have challenged the operation and control of U.S. power grid. It is crucial to develop proactive strategies to assist grid operators for better emergency response and minimized electricity service interruptions; the better the grid may be preserved, the faster the grid can be restored. In this paper, we propose a proactive posturing of power system elements, and formulate a Security-Constrained Optimal Power Flow (SCOPF) informed by cross-domain hurricane modeling as well as its potential impacts on grid elements. Simulation results based on real-world power grid and historical hurricane event have verified the applicability of the proposed optimization formulation, which shows potential to enable grid operators and planners with interactive cross-domain data analytics for mitigating hurricane impacts.

eess.SY

Recovery Time Metric Demonstrated on Real-world Electric Grid for Hurricane Impacted Outages

This work proposes a methodology for estimating recovery times for transmission lines and substations, and is demonstrated on a real-world 1269-bus power system model of Puerto Rico under 20 hurricane scenarios, or stochastic realizations of asset failure under the meteorological conditions of Hurricane Maria. The method defines base recovery times for system components and identifies factors that impact these base values by means of multipliers. While the method is tested on transmission lines and substation failures due to hurricanes, it is based on a generic process that could be applied to any system component or event as a general recovery time estimation framework. The results show that given the two failure modes under study (transmission towers and substations), transmission towers appear to have a greater impact on recovery time estimates despite substations being given longer base outage times. Additionally, average recovery times for the simulated hurricanes across 20 scenarios is ~28,000 work crew days.

eess.SY

Non-Stationary Power System Forced Oscillation Analysis using Synchrosqueezing Transform

Non-stationary forced oscillations (FOs) have been observed in power system operations. However, most detection methods assume that the frequency of FOs is stationary. In this paper, we present a methodology for the analysis of non-stationary FOs. Firstly, Fourier synchrosqueezing transform (FSST) is used to provide a concentrated time-frequency representation of the signals that allows identification and retrieval of non-stationary signal components. To continue, the Dissipating Energy Flow (DEF) method is applied to the extracted components to locate the source of forced oscillations. The methodology is tested using simulated as well as real PMU data. The results show that the proposed FSST-based signal decomposition provides a systematic framework for the application of DEF Method to non-stationary FOs.

eess.SP

Optimal Future Sub-Transmission Volt-Var Planning Tool to Enable High PV Penetration

This paper proposes a reactive power planning tool for sub-transmission systems to mitigate voltage violations and fluctuations caused by high photovoltaic (PV) penetration and intermittency with a minimum investment cost. The tool considers all existing volt-ampere reactive (var) assets in both sub-transmission and distribution systems to reduce the need of new equipment. The planning tool coordinates with an operational volt-var optimization tool to determine all scenarios with voltage violations and verify the planning results. The planning result of each scenario is the solution of a proposed optimal power-flow framework with efficient techniques to handle a high number of discrete variables. The final planning decision is obtained from the planning results of all selected violated scenarios by using two different approaches - direct combination of all single-step solutions and final investment decision based only on the scenarios that are representative for the power-flow voltage violations at most time steps. The final planning decision is verified using a realistic large-scale sub-transmission system and 5-minute PV and load data. The results show a significant voltage violation reduction with a less investment cost for additional var equipment compared to conventional approaches.

eess.SY