SearcharxivSearch

arXiv subjects

Marcin Lewandowski

Publications and source records attributed to Marcin Lewandowski.

5 recordsLinked to original sources

A Benchmark for Audio Reasoning Capabilities of Multimodal Large Language Models

The present benchmarks for testing the audio modality of multimodal large language models concentrate on testing various audio tasks such as speaker diarization or gender identification in isolation. Whether a multimodal model can answer the questions that require reasoning skills to combine audio tasks of different categories, cannot be verified with their use. To address this issue, we propose Audio Reasoning Tasks (ART), a new benchmark for assessing the ability of multimodal models to solve problems that require reasoning over audio signal.

cs.SD

Preservation of Language Understanding Capabilities in Speech-aware Large Language Models

The paper presents C3T (Cross-modal Capabilities Conservation Test), a new benchmark for assessing the performance of speech-aware large language models. The benchmark utilizes textual tasks and a voice cloning text-to-speech model to quantify the extent to which language understanding capabilities are preserved when the model is accessed via speech input. C3T quantifies the fairness of the model for different categories of speakers and its robustness across text and speech modalities.

cs.CL

Implicit Neural Representations for Speed-of-Sound Estimation in Ultrasound

Accurate estimation of the speed-of-sound (SoS) is important for ultrasound (US) image reconstruction techniques and tissue characterization. Various approaches have been proposed to calculate SoS, ranging from tomography-inspired algorithms like CUTE to convolutional networks, and more recently, physics-informed optimization frameworks based on differentiable beamforming. In this work, we utilize implicit neural representations (INRs) for SoS estimation in US. INRs are a type of neural network architecture that encodes continuous functions, such as images or physical quantities, through the weights of a network. Implicit networks may overcome the current limitations of SoS estimation techniques, which mainly arise from the use of non-adaptable and oversimplified physical models of tissue. Moreover, convolutional networks for SoS estimation, usually trained using simulated data, often fail when applied to real tissues due to out-of-distribution and data-shift issues. In contrast, implicit networks do not require extensive training datasets since each implicit network is optimized for an individual data case. This adaptability makes them suitable for processing US data collected from varied tissues and across different imaging protocols. We evaluated the proposed SoS estimation method based on INRs using data collected from a tissue-mimicking phantom containing four cylindrical inclusions, with SoS values ranging from 1480 m/s to 1600 m/s. The inclusions were immersed in a material with an SoS value of 1540 m/s. In experiments, the proposed method achieved strong performance, clearly demonstrating the usefulness of implicit networks for quantitative US applications.

cs.LG

Estimating the ultrasound attenuation coefficient using convolutional neural networks -- a feasibility study

Attenuation coefficient (AC) is a fundamental measure of tissue acoustical properties, which can be used in medical diagnostics. In this work, we investigate the feasibility of using convolutional neural networks (CNNs) to directly estimate AC from radio-frequency (RF) ultrasound signals. To develop the CNNs we used RF signals collected from tissue mimicking numerical phantoms for the AC values in a range from 0.1 to 1.5 dB/(MHz*cm). The models were trained based on 1-D patches of RF data. We obtained mean absolute AC estimation errors of 0.08, 0.12, 0.20, 0.25 for the patch lengths: 10 mm, 5 mm, 2 mm and 1 mm, respectively. We explain the performance of the model by visualizing the frequency content associated with convolutional filters. Our study presents that the AC can be calculated using deep learning, and the weights of the CNNs can have physical interpretation.

physics.med-ph

WaveFlow - Towards Integration of Ultrasound Processing with Deep Learning

The ultimate goal of this work is a real-time processing framework for ultrasound image reconstruction augmented with machine learning. To attain this, we have implemented WaveFlow - a set of ultrasound data acquisition and processing tools for TensorFlow. WaveFlow includes: ultrasound Environments (connection points between the input raw ultrasound data source and TensorFlow) and signal processing Operators (ops) library. Raw data can be processed in real-time using algorithms available both in TensorFlow and WaveFlow. Currently, WaveFlow provides ops for B-mode image reconstruction (beamforming), signal processing and quantitative ultrasound. The ops were implemented both for the CPU and GPU, as well as for built-in automated tests and benchmarks. To demonstrate WaveFlow's performance, ultrasound data were acquired from wire and cyst phantoms and elaborated using selected sequences of the ops. We implemented and evaluated: Delay-and-Sum beamformer, synthetic transmit aperture imaging (STAI), plane-wave imaging (PWI), envelope detection algorithm and dynamic range clipping. The benchmarks were executed on the NVidia Titan X GPU integrated in the USPlatform research scanner (us4us Ltd., Poland). We achieved B-mode image reconstruction frame rates of 55 fps, 17 fps for the STAI and the PWI algorithms, respectively. The results showed the feasibility of real-time ultrasound image reconstruction using WaveFlow operators in the TensorFlow framework. WaveFlow source code can be found at github.com/waveflow-team/waveflow

eess.SP