Marcio E. C. Rodrigues

Publications and source records attributed to Marcio E. C. Rodrigues.

3 recordsLinked to original sources

Human Exposure to Non-Ionizing Radiation from Indoor Distributed Antenna System: Shopping Mall Measurement Analysis

It is crucial to monitor the levels of Non-Ionizing Radiation (NIR) to which the general population may be exposed and compare them to the limits defined in the current standards, in view of the rapid rise of communication services and the prospects of a connected society. A high number of people visits shopping malls and since these locations usually have several indoor antennas close to the public, it is therefore a kind of place that must be evaluated. Thus, this work presents measurements of the electric field in a shopping mall located in Natal, Brazil. We proposed a set of six measurement points, following two criteria: places with great the flow of people and the presence of one or more Distributed Antenna System (DAS), co-sited or not with WiFi access points. Results are presented and discussed in terms of the distance to DAS (conditions: near and far) and flow density of people in the mall (scenarios: low and high number of people). The highest peaks of electric field measured were 1.96 and 3.26 V/m, respectively corresponding to 5% and 8% of the limits defined by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) and the Brazilian National Telecommunication Agency (ANATEL).

cs.NI

Analysis of Measurements in a Microwave Oven with High Level of Non-Ionizing Radiation (NIR) Before and After Repair

Non-ionizing radiation is the subject of several applications, such as the microwave oven, which is very popular. Its use is characterized by direct user operation and reduced distances between users and the NIR source. Therefore, the level of human exposure in this scenario deserves attention as it is a potential cause of biological effects. In this sense, this paper presents the measurement of a microwave oven with a high level of NIR (above the limit defined by the standard) before and after two types of suggested repairs: the use of epoxy putty (Repair 1) and the replacement of the external surface of the oven (Repair 2). The definitions of measurement methodology, based on FDA and INMETRO standards, are presented and discussed. Finally, we describe an analysis of the efficiency of these repair methods aiming at the safety operation.

cs.NI

Vertical Assessment of RF-EMF Exposure in a Building Adjacent to a Multi-Operator Shared Base Station

This paper extends a previously published proposed approach for estimating worst-case exposure scenarios in buildings using publicly available Base Station (BS) parameters, applying it to a critical case involving a multi-operator shared site. Radiofrequency Electromagnetic Fields (RF-EMF) exposure was assessed on every floor of a 20-story building facing the site, revealing significantly higher levels near the center of the antennas' estimated vertical zone of interest, with a peak of 31.86 V/m, 23.95 times higher than the street-level peak value. However, due to uncertainties in the input parameters, measurements across all locations within the zone of interest are required to accurately identify the floor of maximum exposure. The results demonstrate the usefulness of the proposed estimation approach and highlight the need for improved methods that consider BS antenna configurations and current technical information to ensure accurate assessments of exposure to RF-EMF.

cs.NI