SearcharxivSearch

arXiv subjects

Marco Balata

Publications and source records attributed to Marco Balata.

2 recordsLinked to original sources

Procurement and Purification of Liquid Argon for the LEGEND-200 Experiment

LEGEND-200 requires high-purity liquid argon for effective background discrimination. In this paper, we present the design, construction, and performance of a dedicated liquid argon purification system, along with the procurement and purification of liquid argon for filling the LEGEND-200 cryostat to its total capacity of 91 t. The purifier is based on copper catalyst and molecular sieve to remove oxygen and water. Starting with liquid argon of 5.5 quality, featuring an effective scintillation light triplet lifetime $\tau_t$ of about 0.9 $\mu$s, we achieved a final purity corresponding to $\tau_t$ = 1.3 $\mu$s. After complete filling of the LEGEND-200 cryostat, the measured effective triplet lifetime was 1.16 $\mu$s. The notable reduction is caused by a residual nitrogen impurity introduced by an accidentally spoiled liquid argon delivery. An excessive nitrogen influx was prevented by the LEGEND Liquid Argon Monitoring Apparatus (LLAMA), which served as one of the three independent purity monitors during the filling campaign.

physics.ins-det

Modeling of GERDA Phase II data

The GERmanium Detector Array (GERDA) experiment at the Gran Sasso underground laboratory (LNGS) of INFN is searching for neutrinoless double-beta ($0\nu\beta\beta$) decay of $^{76}$Ge. The technological challenge of GERDA is to operate in a "background-free" regime in the region of interest (ROI) after analysis cuts for the full 100$\,$kg$\cdot$yr target exposure of the experiment. A careful modeling and decomposition of the full-range energy spectrum is essential to predict the shape and composition of events in the ROI around $Q_{\beta\beta}$ for the $0\nu\beta\beta$ search, to extract a precise measurement of the half-life of the double-beta decay mode with neutrinos ($2\nu\beta\beta$) and in order to identify the location of residual impurities. The latter will permit future experiments to build strategies in order to further lower the background and achieve even better sensitivities. In this article the background decomposition prior to analysis cuts is presented for GERDA Phase II. The background model fit yields a flat spectrum in the ROI with a background index (BI) of $16.04^{+0.78}_{-0.85} \cdot 10^{-3}\,$cts/(kg$\cdot$keV$\cdot$yr) for the enriched BEGe data set and $14.68^{+0.47}_{-0.52} \cdot 10^{-3}\,$cts/(kg$\cdot$keV$\cdot$yr) for the enriched coaxial data set. These values are similar to the one of Gerda Phase I despite a much larger number of detectors and hence radioactive hardware components.

nucl-ex