Beyond Scalar Inertia: Frequency-Response-Based Assessment of Finite-Duration Inertial Support in Grid-Forming Converters

Conventional scalar inertia characterizes only the low-frequency terminal behavior of grid-forming converters (GFMs) and cannot fully predict inertial energy delivery during short-duration frequency disturbances. This letter proposes a frequency-response-based method to assess finite-duration inertial support using complex terminal power--frequency responses, such as those provided by Network Frequency Perturbation (NFP) plots. For GFMs with nonzero steady-state droop, a duration-dependent energy-equivalent inertia is defined after subtracting the ideal static-droop contribution. An exact spectral relationship is established, expressing this metric as a duration-weighted integral of frequency-dependent inertia, without requiring knowledge of the internal controller structure and parameters. The duration dependence of the metric is further shown to encode observable oscillation frequencies and damping ratios. A coefficient-decoupling GFM control with identical scalar inertia and droop across different settings is used for verification.

eess.SY↗

Solid State Transformer - Next Generation MV Interface for Native DC loads

About PowerNexa PowerNexa is the project name for a start- up initiative driven by Marco Liserre and Steffan Hansen with the ambition to develop the next generation power grid interface. Battery integration and DC loads Ongoing electrification is fundamentally changing how electrical energy is produced and consumed. DC loads are becoming an integral part of the infrastructure while battery integration is increasingly needed to manage peak demand and address grid capacity constraints. The next generation grid interface PowerNexa aims to combine a fully controllable Medium Voltage grid interface with native battery integration and multiple DC voltage levels, based on an architecture designed for high efficiency, modularity and redundancy.

eess.SY↗

Stability Analysis in IBR-Dominated Grids: Model-Based and Data-Driven Methodologies

Stability issues in converter-dominated grids have a multifold nature, where static, small-signal and large-signal phenomena can influence each other. Capturing the interplay among these different stability aspects requires a rethinking of conventional modeling and analysis tools for power systems. As a further complication, Intellectual Property protection among manufacturers and system operators makes detailed converters and grid models unattainable. This motivates the use of data-driven approaches for stability analysis and control, nevertheless achieving an insightful representation of static, small-signal and large-signal phenomena from data still leaves many open questions. This paper discusses model-based and data-driven methodologies for stability analysis of converter-dominated grids. The instability mechanisms of static, small-signal and large-signal phenomena are conceptually explained, and the capability of different modeling and analysis tools to investigate them is examined. The effectiveness of data-driven methodologies to analyze instability phenomena in their multifold nature is debated, and the challenges on data completeness, model generalization under untrained conditions, physical interpretability, and uncertainty awareness are discussed.

eess.SY↗

Physics-Informed Neural Network for Parameter Identification: a Buck Converter Case Study

System-level condition monitoring methods estimate the electrical parameters of multiple components in a converter to assess their health status. The estimation accuracy and variation can differ significantly across parameters. For instance, inductance estimations are generally more accurate and stable than inductor resistance in a buck converter. However, these performance differences remain to be analyzed with a more systematic approach otherwise the condition monitoring results can be unreliable. Therefore, this paper analyzes the training loss landscape against multiple parameters of a buck converter to provide a systematic explanation of different performances. If the training loss is high and smooth, the estimated circuit parameter typically is accurate and has low variation. Furthermore, a novel physics-informed neural network (PINN) is proposed, offering faster convergence and lower computation requirements compared to an existing PINN method. The proposed method is validated through simulations, where the loss landscape identifies the unreliable parameter estimations, and the PINN can estimate the remaining parameters.

eess.SP↗

A Data-Driven Condition Monitoring Method for Capacitor in Modular Multilevel Converter (MMC)

The modular multilevel converter (MMC) is a topology that consists of a high number of capacitors, and degradation of capacitors can lead to converter malfunction, limiting the overall system lifetime. Condition monitoring methods can be applied to assess the health status of capacitors and realize predictive maintenance to improve reliability. Current research works for condition monitoring of capacitors in an MMC mainly monitor either capacitance or equivalent series resistance (ESR), while these two health indicators can shift at different speeds and lead to different end-of-life times. Hence, monitoring only one of these parameters may lead to unreliable health status evaluation. This paper proposes a data-driven method to estimate capacitance and ESR at the same time, in which particle swarm optimization (PSO) is leveraged to update the obtained estimations. Then, the results of the estimations are used to predict the sub-module voltage, which is based on a capacitor voltage equation. Furthermore, minimizing the mean square error between the predicted and actual measured voltage makes the estimations closer to the actual values. The effectiveness and feasibility of the proposed method are validated through simulations and experiments.

eess.SP↗

Modelling of AC/DC Interactions of Converter-Interfaced Resources for Harmonic Power-Flow Studies in Microgrids

Power distribution systems experience a large-scale integration of Converter-Interfaced Distributed Energy Resources (CIDERs). As acknowledged by recent literature, the interaction of individual CIDER components and different CIDERs through the grid can lead to undesirable amplification of harmonic frequencies and, ultimately, compromise the distribution system stability. In this context, the interaction of the DC and AC sides of CIDERs has been shown to have a significant impact. In order to analyze and support the mitigation of such phenomena, the authors of this paper recently proposed a Harmonic Power-Flow (HPF) framework for polyphase grids with a high share of CIDERs. The framework considers the coupling between harmonics, but ignores the DC-side response of the CIDERs. Modelling the DC side and AC/DC converter introduces a nonlinearity into the CIDER model that needs to be approximated for the numerical solution of the HPF. This paper extends the CIDER model and HPF framework to address this aspect, whose inclusion is non-trivial. The extended HPF method is applied to a modified version of the CIGRE low-voltage benchmark microgrid. The results are compared to (i) time-domain simulations with Simulink, (ii) the predecessor of the extended HPF which neglects the DC side, and (iii) a classical decoupled HPF.

eess.SY↗

Harmonic Power-Flow Study of Polyphase Grids with Converter-Interfaced Distributed Energy Resources, Part I: Modelling Framework and Algorithm

Power distribution systems are experiencing a large-scale integration of Converter-Interfaced Distributed Energy Resources (CIDERs). This complicates the analysis and mitigation of harmonics, whose creation and propagation are facilitated by the interactions of converters and their controllers through the grid. In this paper, a method for the calculation of the so-called Harmonic Power-Flow (HPF) in three-phase grids with CIDERs is proposed. The distinguishing feature of this HPF method is the generic and modular representation of the system components. Notably, as opposed to most of the existing approaches, the coupling between harmonics is explicitly considered. The HPF problem is formulated by combining the hybrid nodal equations of the grid with the closed-loop transfer functions of the CIDERs, and solved using the Newton-Raphson method. The grid components are characterized by compound electrical parameters, which allow to represent both transposed or non-transposed lines. The CIDERs are represented by modular linear time-periodic systems, which allows to treat both grid-forming and grid-following control laws. The method's accuracy and computational efficiency are confirmed via time-domain simulations of the CIGRÉ low-voltage benchmark microgrid. This paper is divided in two parts, which focus on the development (Part I) and the validation (Part II) of the proposed method.

eess.SY↗

Harmonic Power-Flow Study of Polyphase Grids with Converter-Interfaced Distributed Energy Resources, Part II: Model Library and Validation

In Part I, a method for the Harmonic Power-Flow (HPF) study of three-phase power grids with Converter-Interfaced Distributed Energy Resources (CIDERs) is proposed. The method is based on generic and modular representations of the grid and the CIDERs, and explicitly accounts for coupling between harmonics. In Part II, the HPF method is validated. First, the applicability of the modeling framework is demonstrated on typical grid-forming and grid-following CIDERs. Then, the HPF method is implemented in Matlab and compared against time-domain simulations with Simulink. The accuracy of the models and the performance of the solution algorithm are assessed for individual resources and a modified version of the CIGRÉ low-voltage benchmark microgrid (i.e., with additional unbalanced components). The observed maximum errors are 6.3E-5 p.u. w.r.t. voltage magnitude, 1.3E-3 p.u. w.r.t. current magnitude, and 0.9 deg w.r.t. phase. Moreover, the scalability of the method is assessed w.r.t. the number of CIDERs and the maximum harmonic order ($\leqslant$25). For the maximum problem size, the execution time of the HPF method is 6.52 sec, which is 5 times faster than the time-domain simulation. The convergence of the method is robust w.r.t. the choice of the initial point, and multiplicity of solutions has not been observed.