SearcharxivSearch

arXiv subjects

Marco Pisani

Publications and source records attributed to Marco Pisani.

6 recordsLinked to original sources

A Six-Quadrupole Diamagnetic Suspension Architecture for Ultra-Sensitive Space Accelerometry

This paper proposes a novel inertial sensor based on a solid diamagnetic cubic test mass passively suspended by a symmetric configuration of six magnetic quadrupoles. Designed specifically for microgravity environments, this system eliminates the mechanical noise and hysteresis inherent in elastic suspensions, as well as the complexity associated with electrostatic suspension systems. We provide an analysis of the magnetic intrinsic noise floor imposed by eddy current damping, alongside ground-based preliminary experimental results demonstrating potential sensitivities in the order of the $10^{-10} \text{ m/s}^2/\sqrt{\text{Hz}}$ regime.

physics.ins-det

Progress on the Astrometric Gravitation Probe design

The Astrometric Gravitation Probe mission is a modern version of the 1919 Dyson-Eddington-Davidson experiment, based on a space-borne telescope with a permanent built-in eclipse, provided by a coronagraphic system. The expected improvement on experimental bounds to General Relativity and competing gravitation theories is by at least two orders of magnitude. The measurement principle is reviewed, in particular the principle of Fizeau-like combination of a set of individual inverted coronagraphs simultaneously feeding a common high resolution telescope. Also, the payload has a dual field of view property, in order to support simultaneous observations of stellar fields either very close, or far away, from the Sun, i.e. fields affected by either high or low light bending. We discuss a set of solutions introduced in the optical design to improve on technical feasibility and robustness of the optical performance against perturbations, in particular induced by manufacturing and alignment tolerances, and launch stresses.

astro-ph.IM

The ASTRA project: a doorway to future astrometry

Astrometric Science and Technology Roadmap for Astrophysics (ASTRA) is a bilateral cooperation between China and Italy with the goal of consolidating astrometric measurement concepts and technologies. In particular, the objectives include critical analysis of the Gaia methodology and performance, as well as principle demonstration experiments aimed at future innovative astrometric applications requiring high precision over large angular separations (one to 180 degrees). Such measurement technologies will be the building blocks for future instrumentation focused on the "great questions" of modern cosmology, like General Relativity validity (including Dark Matter and Dark Energy behavior), formation and evolution of structure like proto-galaxies, and planetary systems formation in bio compatibles environments. We describe three principle demonstration tests designed to address some of the potential showstoppers for high astrometric precision experiments. The three tests are focused on the key concepts of multiple fields telescopes, astrometric metrology and very fine sub-pixel precision (goal: <1/2000 pixel) in white light.

astro-ph.IM

Systematic errors in the correlation method for Johnson noise thermometry: residual correlations due to amplifiers

Johnson noise thermometers (JNT) measure the equilibrium electrical noise, proportional to thermodynamic temperature, of a sensing resistor. In the correlation method, the same resistor is connected to two amplifiers and a correlation of their outputs is performed, in order to reject amplifiers' noise. Such rejection is not perfect: the residual correlation gives a systematic error in the JNT reading. In order to put an upper limit, or to achieve a correction, for such error, a careful electrical modelling of the amplifiers and connections must be performed. Standard numerical simulation tools are inadequate for such modelling. In literature, evaluations have been performed by the painstaking solving of analytical modelling. We propose an evaluation procedure for the JNT error due to residual correlations which blends analytical and numerical approaches, with the benefits of both: a rigorous and accurate circuit noise modelling, and a fast and flexible evaluation with an user-friendly commercial tool. The method is applied to a simple but very effective ultralow-noise amplifier employed in a working JNT.

physics.ins-det

An absolute Johnson noise thermometer

We developed an absolute Johnson noise thermometer (JNT), an instrument to measure the thermodynamic temperature of a sensing resistor, with traceability to voltage, resistance and frequency quantities. The temperature is measured in energy units, and can be converted to SI units (kelvin) with the accepted value of the Boltzmann constant kb; or, conversely, it can be employed to perform measurements at the triple point of water, and obtain a determination of kb. The thermometer is composed of a correlation spectrum analyzer an a calibrated noise source, both constructed around commercial mixed-signal boards. The calibrator generates a pseudorandom noise, by digital synthesis and amplitude scaling with inductive voltage dividers; the signal spectrum is a frequency comb covering the measurement bandwidth. JNT measurements at room temperature are compatible with those of a standard platinum resistance thermometer within the combined uncertainty of 60 ppm. A path towards future improvements of JNT accuracy is also sketched.

physics.ins-det

Very simple FET amplifier with a voltage noise floor less than 1 nV/sqrt(Hz)

A field-effect transistor (FET) amplifier for small voltage signals is presented. Its design is elementary and the construction can be afforded by anyone. Despite its simplicity, with a voltage noise less than 1 nV/sqrt(Hz), it outperforms commercially available integrated FET amplifiers. The amplifier has a gain flatness better than 1 dB over 1 MHz bandwidth; it can be employed as a front-end for signal analyzers or signal recovery systems.

physics.ins-det