SearcharxivSearch

arXiv subjects

Marco Pizzocaro

Publications and source records attributed to Marco Pizzocaro.

15 recordsLinked to original sources

International Optical Clock Comparison Using the European Optical Fiber Network

Optical clocks have achieved remarkable estimated fractional frequency uncertainties reaching the $10^{-18}$ level and below, enabling applications in fundamental physics, general relativity, and geodesy. However, the challenge of verifying the international consistency of optical clocks remains critical as efforts intensify toward redefining the SI second based on an optical transition or transitions. We report on a two-month international clock comparison campaign involving seven optical clocks in four national metrology institutes (INRIM, LNE-OP, NPL, and PTB) connected via the optical fiber network established in Europe. The campaign resulted in optical frequency ratios with uncertainties ranging from $7.7\times10^{-18}$ to $6.1\times10^{-17}$. Among the results, the $^{171}$Yb$^+$(E3) clocks at NPL and PTB demonstrated agreement within an uncertainty of $7.7\times10^{-18}$, marking the first international verification of two independently developed optical clocks below one part in $10^{17}$. The operation of the $^{199}$Hg clock at LNE-OP (formerly LNE-SYRTE) resulted in frequency ratios with improved uncertainties with $^{171}$Yb$^+$(E3), $^{171}$Yb, and $^{87}$Sr optical clocks. These results provide input for the redefinition of the second and underscore how fiber-linked clock networks can advance metrology and scientific applications.

physics.atom-ph

A High-frequency Geodetic VLBI Experiment for Optical Clock Comparison

An intercontinental metrological clock comparison between Italy and the Republic of Korea was performed by means of geodetic K-band VLBI observations. The comparison involved the hydrogen masers (H-masers) used at Medicina and Sejong radio telescopes. The same clocks were simultaneously compared by a satellite link and by high-precision optical clocks maintained at the National Metrology Institutes, KRISS in Korea and INRIM in Italy, and delivered to VLBI antennas via optical fiber. The H-masers frequency difference was estimated by extrapolating the clock rate from VLBI data using two geodetic VLBI software. This was subsequently compared with clock differences derived by satellite link and by local optical clocks. Results obtained with different approaches were in agreement at the level of $10^{-15}$ s/s. This pilot study demonstrates that standard high-frequency (K-band) geodetic VLBI campaigns could be a viable approach to conduct intercontinental clock comparisons, now only possible via satellite links. This uncertainty can be reduced thanks to the planned installation of new-generation, broadband, high-frequency receivers on the involved telescopes. K/Q/W-band geodetic observations will allow an improvement of the accuracy of the resulting group delays through broad bandwidth synthesis from 20 to 100 GHz. Furthermore, the Frequency Phase Transfer (FPT) method will also be explored together with the use of PCAL systems installed at the radio telescopes to improve phase stability and thus allow a better estimation of the station clock parameters.

astro-ph.IM

Atomic thermometry in optical lattice clocks

Accurate measurement of atomic temperature is fundamental for a wide range of applications, from quantum sensing to precision metrology. In optical lattice clocks, precise characterization of atomic temperature is required to minimize systematic uncertainties at the $10^{-18}$ level. In this work, we investigate atomic temperature measurements in the ytterbium optical lattice clock developed at INRIM, IT-Yb1, employing sideband and Doppler spectroscopy across a wide range of trapping conditions. By implementing clock-line-mediated Sisyphus cooling [Phys. Rev. Lett. 133, 053401 (2024)], we reduce the atomic temperature and enable operation at shallower lattice depths down to $D = 50E_{R}$. We compare temperature estimates obtained from the harmonic oscillator model with those derived using a Born-Oppenheimer-based approach [Phys. Rev. A 101, 053416 (2020)], which is expected to provide a more accurate description of atomic motion in both longitudinal and radial directions, especially for hotter atoms whose motion deviates from the harmonic regime. Discrepancies up to a factor of two in extracted temperatures are observed depending on the chosen model. We assess the impact of these modeling differences on the evaluation of lattice shifts and find relative frequency deviations up to $8\times10^{-17}$. Even though extended Sisyphus cooling reduces these inconsistencies to the $1\times10^{-18}$ level, residual biases may still limit the accuracy of optical lattice clocks.

physics.atom-ph

Coordinated international comparisons between optical clocks connected via fiber and satellite links

Optical clocks provide ultra-precise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time, while others had significantly lower uncertainties than previously achieved, supporting the advance towards a redefinition of the second and the use of optical standards for international time scales.

physics.atom-ph

Absolute frequency measurement of a Yb optical clock at the limit of the Cs fountain

We present the new absolute frequency measurement of ytterbium (171Yb) obtained at INRiM with the optical lattice clock IT-Yb1 against the cryogenic caesium (133Cs) fountain IT-CsF2, evaluated through a measurement campaign that lasted 14 months. Measurements are performed by either using a hydrogen maser as a transfer oscillator or by synthesizing a low-noise microwave for Cs interrogation using an optical frequency comb. The frequency of the 171Yb unperturbed clock transition 1S0 - 3P0 results to be 518 295 836 590 863.44(14) Hz, with a total fractional uncertainty of 2.7e-16 that is limited by the uncertainty of IT-CsF2. Our measurement is in agreement with the Yb frequency recommended by the Consultative Committee for Time and Frequency (CCTF). This result confirms the reliability of Yb as a secondary representation of the second and is relevant to the process of redefining the second in the International System of Units (SI) on an optical transition

physics.atom-ph

Improving the resolution of comb-based frequency measurements using a track and hold amplifier

The advent of optical frequency standards with ultimate uncertainties in the low 1x10$^{-18}$ requires femtosecond frequency combs to support a similar level of resolution in the spectral transfer and the computation of optical frequency ratios. The related experimental challenges grow together with the number of optical frequencies to be measured simultaneously, as in many cases the comb's optical power does not allow reliable beatnote counting or tracking in all the spectral regions of interest. Here we describe the use of a track-and-hold amplifier to implement the gated detection, a previously proposed technique for improving the signal-to-noise ratio of the beatnote between a low-power tooth of the frequency comb and a continuous wave laser. We demonstrate a 12dB improvement in the signal-to-noise ratio of beatnotes involving a broadband-spanning optical comb as compared to traditional detection schemes. Our approach enables reliable and cycle-slip-free spectral purity transfer and reduces the system sensitivity to power drops in the comb spectrum. Being based on a single chip, it is robust, versatile and easily embedded in more complex experimental schemes. Keywords: frequency comb, spectral purity transfer, gated detection, track and hold amplifier.

physics.ins-det

Guidelines for developing optical clocks with $10^{-18}$ fractional frequency uncertainty

There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.

physics.atom-ph

Phase noise cancellation in polarisation-maintaining fibre links

The distribution of ultra-narrow linewidth laser radiation is an integral part of many challenging metrological applications. Changes in the optical pathlength induced by environmental disturbances compromise the stability and accuracy of optical fibre networks distributing the laser light and call for active phase noise cancellation. Here we present a laboratory scale optical (at 578 nm) fibre network featuring all polarisation maintaining fibres in a setup with low optical powers available and tracking voltage-controlled oscillators implemented. The stability and accuracy of this system reach performance levels below 1 * 10^(-19) after 10 000 s of averaging

physics.ins-det

Geodesy and metrology with a transportable optical clock

The advent of novel measurement instrumentation can lead to paradigm shifts in scientific research. Optical atomic clocks, due to their unprecedented stability and uncertainty, are already being used to test physical theories and herald a revision of the International System of units (SI). However, to unlock their potential for cross-disciplinary applications such as relativistic geodesy, a major challenge remains. This is their transformation from highly specialized instruments restricted to national metrology laboratories into flexible devices deployable in different locations. Here we report the first field measurement campaign performed with a ubiquitously applicable $^{87}$Sr optical lattice clock. We use it to determine the gravity potential difference between the middle of a mountain and a location 90 km apart, exploiting both local and remote clock comparisons to eliminate potential clock errors. A local comparison with a $^{171}$Yb lattice clock also serves as an important check on the international consistency of independently developed optical clocks. This campaign demonstrates the exciting prospects for transportable optical clocks.

physics.atom-ph

Absolute frequency measurement of the 1S0 - 3P0 transition of 171Yb

We report the absolute frequency measurement of the unperturbed transition 1S0 - 3P0 at 578 nm in 171Yb realized in an optical lattice frequency standard. The absolute frequency is measured 518 295 836 590 863.55(28) Hz relative to a cryogenic caesium fountain with a fractional uncertainty of 5.4x10-16 . This value is in agreement with the ytterbium frequency recommended as a secondary representation of the second in the International System of Units.

physics.atom-ph

A compact ultranarrow high-power laser system for experiments with 578nm Ytterbium clock transition

In this paper we present the realization of a compact, high-power laser system able to excite the Ytterbium clock transition at 578 nm. Starting from an external-cavity laser based on a quantum dot chip at 1156 nm with an intra-cavity electro-optic modulator, we were able to obtain up to 60 mW of visible light at 578 nm via frequency doubling. The laser is locked with a 500 kHz bandwidth to a ultra-low-expansion glass cavity stabilized at its zero coefficient of thermal expansion temperature through an original thermal insulation and correction system. This laser allowed the observation of the clock transition in fermionic $^{173}$Yb with a < 50 Hz linewidth over 5 minutes, limited only by a residual frequency drift of some 0.1 Hz/s.

physics.optics

Direct observation of coherent inter-orbital spin-exchange dynamics

We report on the first direct observation of fast spin-exchange coherent oscillations between different long-lived electronic orbitals of ultracold $^{173}$Yb fermions. We measure, in a model-independent way, the strength of the exchange interaction driving this coherent process. This observation allows us to retrieve important information on the inter-orbital collisional properties of $^{173}$Yb atoms and paves the way to novel quantum simulations of paradigmatic models of two-orbital quantum magnetism.

cond-mat.quant-gas

Efficient Frequency Doubling at 399 nm

This article describes a high-power and narrow-linewidth laser source at 399 nm useful for cooling and trapping of ytterbium atoms. A continuous-wave titanium-sapphire laser at 798 nm is frequency doubled using a lithium triborate crystal in an enhancement cavity. Up to 1.0 W of light at 399 nm has been obtained from 1.3 W of infrared light, with an efficiency of 80 % This paper was published in Applied Optics and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://www.opticsinfobase.org/ao/abstract.cfm?uri=ao-53-16-3388. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law.

physics.optics

A Large Area Fiber Optic Gyroscope on multiplexed fiber network

We describe a fiber optical gyroscope based on the Sagnac effect realized on a multiplexed telecom fiber network. Our loop encloses an area of 20 km^2 and coexists with Internet data traffic. This Sagnac interferometer achieves a sensitivity of about 1e-8 (rad/s)/sqrt(Hz), thus approaching ring laser gyroscopes without using narrow-linewidth laser nor sophisticated optics. The proposed gyroscope is sensitive enough for seismic applications, opening new possibilities for this kind of optical fiber sensors

physics.optics

Rotational sensitivity of the "G-Pisa" gyrolaser

G-Pisa is an experiment investigating the possibility to operate a high sensitivity laser gyroscope with area less than $1 \rm m^2$ for improving the performances of the mirrors suspensions of the gravitational wave antenna Virgo. The experimental set-up consists in a He-Ne ring laser with a 4 mirrors square cavity. The laser is pumped by an RF discharge where the RF oscillator includes the laser plasma in order to reach a better stability. The contrast of the Sagnac fringes is typically above 50% and a stable regime has been reached with the laser operating both single mode or multimode. The effect of hydrogen contamination on the laser was also checked. A low-frequency sensitivity, below $1 \rm Hz$, in the range of $10^{-8} \rm {(rad / s)/ \sqrt{Hz}}$ has been measured.

physics.optics