SearcharxivSearch

arXiv subjects

Marco Romagnoni

Publications and source records attributed to Marco Romagnoni.

13 recordsLinked to original sources

Satellite-borne $\gamma$-ray astrophysics from coherent interactions in oriented crystals

High-density and high-Z crystals are key elements of most space-borne $\gamma$-ray telescopes operating at gigaelectronvolt energies (such as Fermi-LAT). The lattice structure is usually neglected in the development of a crystalline detector, although its effects on the energy deposit development should be taken into account, since the interactions of a high-energy ($\sim$ 10~GeV) photon or e$^\pm$ impinging along the axis of an oriented crystal are different than those observed in a fully isotropic medium. Specifically, if the angle between a photon (e$^\pm$) trajectory, and the crystal axis is smaller than $\sim$ 0.1$^\circ$, a large enhancement of the pair production (bremsstrahlung) cross section is observed. Consequently, a photon-induced shower inside an oriented crystal develops within a much more compact region than in an amorphous medium. Moreover, for photon energies above a few gigaelectronvolt and incidence angles up to several degrees, the pair production cross section exhibits a pronounced dependence on the angle between the crystal axis and the photon polarization vector. In this work we show that these effects could be exploited to develop a novel class of light-weight pointing space-borne $\gamma$-ray telescopes, capable of achieving an improved sensitivity and resolution, thanks to a better shower containment in a smaller volume, with respect to non-oriented crystalline detectors. We also show that an oriented tracker-converter system could be used to measure the polarization of a $\gamma$-ray source above few gigaelectronvolts, in a regime that remains unexplorable through any other detection technique. This novel detector concept could open new pathways in the study of the physics of extreme astrophysical environments and potentially improve the detector sensitivity for indirect dark matter searches in space

astro-ph.HE

Strong Enhancement of Electromagnetic Shower Development in Oriented Scintillating Crystals and Implications for Particle Detectors

A particle traversing a crystal aligned with one of its crystallographic axes experiences a strong electromagnetic field that is constant along the direction of motion over macroscopic distances. For $e^\pm$ and $γ$-rays with energies above a few $\mathrm{GeV}$, this field is amplified by the Lorentz boost, to the point of exceeding the Schwinger critical field $\mathcal{E}_0 \sim 1.32 \times 10^{16}~\mathrm{V/cm}$. In this regime, nonlinear quantum-electrodynamical effects occur, such as the enhancement of intense electromagnetic radiation emission and pair production, so that the electromagnetic shower development is accelerated and the effective shower length is reduced compared to amorphous materials. We have investigated this phenomenon in lead tungstate (PbWO$_4$), a high-$Z$ scintillator widely used in particle detection. We have observed a substantial increase in scintillation light at small incidence angles with respect to the main lattice axes. Measurements with $120$-$\mathrm{GeV}$ electrons and $γ$-rays between $5$ and $100~\mathrm{GeV}$ demonstrate up to a threefold increase in energy deposition in oriented samples. These findings challenge the current models of shower development in crystal scintillators and could guide the development of next-generation accelerator- and space-borne detectors.

hep-ex

Apparatus for the measurement of birefringence maps of optical materials: the case of crystalline silicon for Einstein Telescope

Einstein Telescope (ET) is expected to achieve sensitivity improvements exceeding an order of magnitude compared to current gravitational-wave detectors. The rigorous characterization in optical birefringence of materials and coatings has become a critical task for next-generation detectors, especially since this birefringence is generally spatially non-uniform. A highly sensitive optical polarimeter has been developed at the Department of Physics and Earth Sciences of the University of Ferrara and INFN - Ferrara Section, Italy, aimed at performing two-dimensional birefringence mapping of substrates. In this paper we describe the design and working principle of the system and present results for crystalline silicon, a candidate material for substrates in the low-frequency (LF) interferometers of ET. We find that the birefringence is of order $10^{-7}$ for commercially available samples and is position dependent in the silicon (100)-oriented samples, with variations in both magnitude and axis orientation. We also measure the intrinsic birefringence of the (110) surface. Implications for the performance of gravitational-wave interferometers are discussed.

physics.optics

High-Precision Alignment Techniques for Realizing an Ultracompact Electromagnetic Calorimeters Using Oriented high-Z Scintillator Crystals

Electromagnetic calorimeters used in high-energy physics and astrophysics rely heavily on high-Z inorganic scintillators, such as lead tungstate (PbWO4 or PWO). The crystalline structure and lattice orientation of inorganic scintillators are frequently underestimated in detector design, even though it is known that the crystalline lattice strongly modifies the features of the electromagnetic processes inside the crystal. A novel method has been developed for precisely bonding PWO crystals with aligned atomic planes within 100 μrad, exploiting X-ray diffraction (XRD) to accurately measure miscut angles. This method demonstrates the possibility to align a layer of crystals along the same crystallographic direction, opening a new technological path towards the development of next-generation electromagnetic calorimeters.

physics.ins-det

FCC-ee positron source from conventional to crystal-based

The high-luminosity requirement in future lepton colliders imposes a need for a high-intensity positron source. In the conventional scheme, positron beams are obtained by the conversion of bremsstrahlung photons into electron-positron pairs through the interaction between a high-energy electron beam and a high-Z amorphous target. One method to enhance the number of produced positrons is by boosting the incident electron beam power. However, the maximum heat load and thermo-mechanical stresses bearable by the target severely limit the beam power of the incident electrons. To overcome these limitations, an innovative approach using lattice coherent effects in oriented crystals appears promising. This approach uses a single thick crystal that serves as a radiator and a converter. In this paper, we investigate the application of this scheme as an alternative to the conventional positron source at the Future Circular Collider (FCC-ee). Simulations were carried out from the positron production stage to the entrance of the damping ring to estimate the accepted positron yield. The results demonstrate the advantages of the crystal-based positron source: it requires thinner targets than the conventional scheme, resulting in a 14% reduction in the deposited power while achieving a 10% increase in accepted positron yield.

physics.acc-ph

Proposal of the KOTO II experiment

The KOTO II experiment is proposed to measure the branching ratio of the decay $K_L\toπ^0ν\barν$ at J-PARC. With a beamline to extract long-lived neutral kaons at 5 degrees from a production target, the single event sensitivity of the decay is $8.5\times 10^{-13}$, which is much smaller than the Standard Model prediction $3\times 10^{-11}$. This allows searches for new physics beyond the Standard Model and the first discovery of the decay with a significance exceeding $5σ$. As the only experiment proposed in the world dedicated to rare kaon decays, KOTO II will be indispensable in the quest for a complete understanding of flavor dynamics in the quark sector. Moreover, by combining efforts from the kaon community worldwide, we plan to develop the KOTO II detector further and expand the physics reach of the experiment to include measurements of the branching ratio of the $K_L\toπ^0\ell^+\ell^-$ decays, studies of other $K_L$ decays, and searches for dark photons, axions, and axion-like particles. KOTO II will therefore obtain a comprehensive understanding of $K_L$ decays, providing further constraints on new physics scenarios with existing $K^+$ results.

hep-ex

Particle identification capability of a homogeneous calorimeter composed of oriented crystals

Recent studies have shown that the electromagnetic shower induced by a high-energy electron, positron or photon incident along the axis of an oriented crystal develops in a space more compact than the ordinary. On the other hand, the properties of the hadronic interactions are not affected by the lattice structure. This means that, inside an oriented crystal, the natural difference between the hadronic and the electromagnetic shower profile is strongly accentuated. Thus, a calorimeter composed of oriented crystals could be intrinsically capable of identifying more accurately the nature of the incident particles, with respect to a detector composed only of non-aligned crystals. Since no oriented calorimeter has ever been developed, this possibility remains largely unexplored and can be investigated only by mean of numerical simulations. In this work, we report the first quantitative evaluation of the particle identification capability of such a calorimeter, focusing on the case of neutron-gamma discrimination. We demonstrate through Geant4 simulations that the use of oriented crystals significantly improves the performance of a Random Forest classifier trained on the detector data. This work is a proof that oriented calorimeters could be a viable option for all the environments where particle identification must be performed with a very high accuracy, such as future high-intensity particle physics experiments and satellite-based gamma-ray telescopes.

hep-ex

Bent Crystal Design and Characterization for High-Energy Physics Experiments

Bent crystal are widely used as optics for X-rays, but via the phenomenon of planar channeling they may act as waveguide for relativistic charged particles beam as well, outperforming some of the traditional technologies currently employed. A physical description of the phenomenon and the resulting potential for applications in a particle accelerator is reported. The elastic properties of the anisotropic crystal lattice medium are discussed, introducing different types of curvature which can enable a wide array of bending schemes optimized for each different case features. The technological development of machining strategy and bending solutions useful for the fabrication of crystals suitable in high energy particle manipulations are described. As well as the high precision characterization processes developed in order to satisfy the strict requirements for installation in an accelerator. Finally, the characterization of channeling phenomenon in bent crystal is described, pointing out several experimental setups suitable to comply each specific case constrains.

physics.acc-ph

Development of crystal optics for Multi-Projection X-ray Imaging for synchrotron and XFEL sources

X-ray Multi-Projection Imaging (XMPI) is an emerging technology that allows for the acquisition of millions of 3D images per second in samples opaque to visible light. This breakthrough capability enables volumetric observation of fast stochastic phenomena, which were inaccessible due to the lack of a volumetric X-ray imaging probe with kHz to MHz repetition rate. These include phenomena of industrial and societal relevance such as fractures in solids, propagation of shock waves, laser-based 3D printing, or even fast processes in the biological domain. Indeed, the speed of traditional tomography is limited by the shear forces caused by rotation, to a maximum of 1000 Hz in state-of-the-art tomography. Moreover, the shear forces can disturb the phenomena in observation, in particular with soft samples or sensitive phenomena such as fluid dynamics. XMPI is based on splitting an X-ray beam to generate multiple simultaneous views of the sample, therefore eliminating the need for rotation. The achievable performances depend on the characteristics of the X-ray source, the detection system, and the X-ray optics used to generate the multiple views. The increase in power density of the X-ray sources around the world now enables 3D imaging with sampling speeds in the kilohertz range at synchrotrons and megahertz range at X-ray Free-Electron Lasers (XFELs). Fast detection systems are already available, and 2D MHz imaging was already demonstrated at synchrotron and XFEL. In this work, we explore the properties of X-ray splitter optics and XMPI schemes that are compatible with synchrotron insertion devices and XFEL X-ray beams. We describe two possible schemes designed to permit large samples and complex sample environments. Then, we present experimental proof of the feasibility of MHz-rate XMPI at the European XFEL.

physics.ins-det

Radiation in oriented crystals: Innovative application to future positron sources

It has been known since decades that the alignment of a beam of high-energy electrons with particular crystal directions involves a significant increase of bremsstrahlung radiation emission. This enhancement lies at the conceptual foundation of innovative positron source schemes for future lepton colliders. In particular, the so-called hybrid scheme makes use of a heavy-metal radiator in crystalline form, which is then followed by an amorphous metallic converter for positron generation from electrons by means of a two-step electromagnetic process. This work presents the most recent simulation results obtained on the development of a hybrid positron source for the FCC-$ee$ from the standpoint of the features of both the crystalline radiator and the amorphous converter.

physics.acc-ph

Development towards high-resolution kHz-speed rotation-free volumetric imaging

X-ray multi-projection imaging (XMPI) provides rotation-free 3D movies of optically opaque samples. The absence of rotation enables superior imaging speed and preserves fragile sample dynamics by avoiding the shear forces introduced by conventional rotary tomography. Here, we present our XMPI observations at the ID19 beamline (ESRF, France) of 3D dynamics in melted aluminum with 1000 frames per second and 8 $μ$m resolution per projection using the full dynamical range of our detectors. Since XMPI is a method under development, we also provide different tests for the instrumentation of up to 3000 frames per second. As the flux of X-ray sources grows globally, XMPI is a promising technique for current and future X-ray imaging instruments.

physics.ins-det

Megahertz X-ray Multi-projection imaging

X-ray time-resolved tomography is one of the most popular X-ray techniques to probe dynamics in three dimensions (3D). Recent developments in time-resolved tomography opened the possibility of recording kilohertz-rate 3D movies. However, tomography requires rotating the sample with respect to the X-ray beam, which prevents characterization of faster structural dynamics. Here, we present megahertz (MHz) X-ray multi-projection imaging (MHz-XMPI), a technique capable of recording volumetric information at MHz rates and micrometer resolution without scanning the sample. We achieved this by harnessing the unique megahertz pulse structure and intensity of the European X-ray Free-electron Laser with a combination of novel detection and reconstruction approaches that do not require sample rotations. Our approach enables generating multiple X-ray probes that simultaneously record several angular projections for each pulse in the megahertz pulse burst. We provide a proof-of-concept demonstration of the MHz-XMPI technique's capability to probe 4D (3D+time) information on stochastic phenomena and non-reproducible processes three orders of magnitude faster than state-of-the-art time-resolved X-ray tomography, by generating 3D movies of binary droplet collisions. We anticipate that MHz-XMPI will enable in-situ and operando studies that were impossible before, either due to the lack of temporal resolution or because the systems were opaque (such as for MHz imaging based on optical microscopy).

eess.IV

Absolute spectral metrology of XFEL pulses using diffraction in crystals

At modern X-ray sources, such as synchrotrons and X-ray Free-Electron Lasers (XFELs), it is important to measure the absolute value of the photon energy directly. Here, a method for absolute spectral metrology is presented. A photon energy estimation method based on the spectral measurements and rocking of diffracting crystals is presented. The photon energy of SASE1 channel of the European XFEL was measured, and the benefits and applications of the precise photon energy evaluation are discussed.

physics.ins-det