Alternative Procedures in Realizing of the High Frequency Power Standards with Microcalorimeter and Thermoelectric Power Sensors

The paper describes the realization process of the high frequency power standard based on a twin broadband microcalorimeter designed for effective efficiency measurement of coaxial power sensors with indirect heating thermocouples. The presented procedures involve microcalorimeter measurement and calibration steps, parameters computation and systematic errors correction for both long-term and accelerated algorithms. Also, a new method for determining the key parameters of high frequency power standards is proposed.

physics.ins-det

Improvement of primary power standard through international comparison feedback

The high frequency primary power standard is univocally realized by means of a coaxial microcalorimeter, at least up to 40 GHz. The coaxial microcalorimeter is a broadband measurement system adjusted for effec-tive efficiency measurement of power sensors both of bolometric and thermoelectric type. The critical point in the power standard realization is in the determination of the calibration constant g of the microcalorimeter, a frequency dependent parameter that has huge impact on the accuracy as-sessment of the standard. The paper proposes a simple but powerful way for improving this accuracy by using the reference values provided by in-ternational key-comparisons which the microcalorimeter was involved in.

physics.ins-det

Comparison between Thermoelectric and Bolometric Microwave Power Standards

In the paper, a comparison is described of the microwave power standard based on thermoelectric sensors against an analogous standard based on bolometric sensors. Measurements have been carried out with the classical twin-type microcalorimeter, fitted with N-connector test ports suitable for the frequency band 0.05 - 18 GHz. An appropriate measurand definition is given for being suitable to both standard types. A system accuracy assessment is performed applying the Gaussian error propagation through the mathematical models that interpret the microcalorimeter response in each case. The results highlight advantages and weaknesses of each power standard type.

physics.ins-det

Uncertainty Analysis for Material Measurements Using the Vector Network Analyzer

This paper presents the characterization measurements and related uncertainty evaluation of a nonmagnetic material using the Vector Network Analyzer (VNA) at microwave frequencies. The permittivity of the material under test is computed from the scattering parameters (S-parameters). The aim of the work is to highlight the different uncertainty contributions affecting the permittivity.

physics.app-ph

Improvements on INRIM Coaxial Microcalorimeter and Outcome of a Model Comparison

This paper describes hardware and software improvements of the INRIM coaxial microcalorimeter together with their outcome on the primary power standard realization in the frequency band 0.05 - 40 GHz. A better temperature and power stabilization turned out to provide an improved signal/noise ratio and a drift reduction in every working condition of the microcalorimeter. The INRIM correction model is also compared to a traditional, but faster, one in terms of measurement uncertainty. Outcomes are presented in form of a 2.92 mm thermoelectric power sensor calibration together with results that show the improved stability and repeatability of the measurement system.

physics.ins-det

The True-Twin microcalorimeter: a proof-of-concept experiment

We present a proof-of-concept experiment to realize microwave primary power standard with a true-twin microcalorimeter. Double feeding line microcalorimeters are widely used by National Metrology Institutes. A drawback concerns the system calibration: traditional processes changes measurement conditions between system characterization and the measurement stage. Nevertheless, if the feeding lines are made twin, a measurement scheme that avoids separate characterization can be applied, equations simplify and time consumption is halved. Here we demonstrates the feasibility of the idea. The result of an effective efficiency spectroscopy of a thermoelectric power sensor is compared with figures obtained with well established methods.

physics.ins-det