SearcharxivSearch

arXiv subjects

Marco Spirito

Publications and source records attributed to Marco Spirito.

2 recordsLinked to original sources

Full Two-Port S-Parameters at mK Temperatures: a Calibration Strategy and Uncertainty Budget

This paper describes the developed setup and characterization approach for full two-port calibrated S-parameter measurements at cryogenic temperatures, together with a complete uncertainty budget. The system developed at the Istituto Nazionale di Ricerca Metrologica (INRiM, Italy), exploits the Short-Open-Load-Reciprocal technique to realize error-corrected cryogenic measurements within a single cooling cycle. The system operates down to mK temperatures over the 4-12 GHz band in coaxial line. Calibration standards are referenced to SI-traceable room-temperature measurements, while a numerical approach is used to evaluate the response shift of the artifacts upon cooling and to derive an additional cryogenic uncertainty contribution for the measurement uncertainty budget. Moreover, relevant measurement uncertainty contributions are evaluated according to internationally agreed procedures, and a comprehensive uncertainty budget is presented. Test measurements on a 20 dB attenuator are shown as an example. An attenuation of 20.70 +/- 0.08 dB (95% confidence interval) was obtained at 6 GHz. Full SI-traceable verification at mK temperatures remains an open challenge; however, an initial calibration verification is also presented.

physics.ins-det

Shielded cantilever with on-chip interferometer circuit for THz scanning probe impedance microscopy

We have realized a microstrip based THz near field cantilever which enables quantitative measurements of the impedance of the probe tip at THz frequencies (0.3 THz). A key feature is the on-chip balanced hybrid coupler which serves as an interferometer for passive signal cancellation to increase the readout circuit sensitivity despite extreme impedance mismatch at the tip. We observe distinct changes in the reflection coefficient of the tip when brought into contact with different dielectric (Si, SrTiO3) and metallic samples (Au). By comparing to finite element simulations we determine the sensitivity of our THz probe to be well below 0.25 fF. The cantilever further allows for topography imaging in a conventional atomic force microscope mode. Our THz cantilever removes several critical technology challenges and thus enables a shielded cantilever based THz near field microscope.

physics.app-ph