An Al$^+$ clock with $1.6\times10^{-18}$ systematic uncertainty and its frequency ratios

Advances in optical clocks motivate a redefinition of the second, requiring rigorous evaluations of systematic uncertainties and robust consistency among the clocks. Here, we report the full evaluation of the systematic frequency shifts of an $^{27}\mathrm{Al}^+$ single-ion clock, and the measurement of its absolute frequency and frequency ratio with a $^{87}$Sr optical lattice clock at PTB. The evaluated total systematic fractional frequency uncertainty is $1.6\times10^{-18}$, mainly limited by the accuracy of the relevant atomic coefficients and by background gas collisions. The absolute frequency of the clock has been measured to be $\nu_{\mathrm{Al}^+}=1 121 015 393 207 859.19(24)\,$Hz, obtained by comparison with two primary caesium fountain clocks at PTB. The frequency ratio between the Al and Sr optical clocks has been determined to be $\nu_{\mathrm{Al}^+}/\nu_{^{87}\mathrm{Sr}}=2.611 701 431 781 462 668(36)$, limited by the accuracy of the Sr clock. This ratio differs by $8.6\sigma$ and $1.2\sigma$ from the 2021 and 2025 frequency ratio published by the BACON collaboration, respectively. These results represent an important contribution toward a future redefinition of the second using optical clocks, and underscore the importance of independent measurements of clock-candidate frequency ratios across different institutions.

physics.atom-ph

A high-stability optical clock based on a continuously ground-state cooled Al$^+$ ion without compromising its accuracy

Single ion optical clocks have shown systematic frequency uncertainties below $10^{-18}$, but typically require more than one week of averaging to achieve a corresponding statistical uncertainty. This time can be reduced with longer probe times, but comes at the cost of a higher time-dilation shift due to motional heating of the ions in the trap. We show that sympathetic ground-state cooling using electromagnetically-induced transparency (EIT) of an \Al clock ion via a co-trapped \Ca ion during clock interrogation suppresses the heating of the ions. \Al can be kept close to the motional ground state, independent from the chosen interrogation time, at a relative time dilation shift of $(-1.69\pm0.20)\times10^{-18}$. The \Ca cooling light introduces an additional light shift on the \Al clock transition of $(-9.27\pm 1.03)\times10^{-18}$. We project that the uncertainty of this light shift can be further reduced by nearly an order of magnitude. This sympathetic cooling enables seconds of interrogation time with $10^{-19}$ motional and cooling laser-induced uncertainties for \Al and can be employed in other ion clocks as well.

physics.atom-ph