Catheter Monitoring in Intelligent Endovascular Navigation Systems: Interactive Simulations and Mixed Reality for Enhanced Navigational Awareness

Purpose: Developing and testing a framework that integrates real-time catheter shape reconstruction, interactive simulations, and mixed reality visualization to enable accurate monitoring of catheter-vessel interactions during endovascular navigation. Methods: A finite element model (FEM) of the venous pathway from the right femoral vein to the inferior vena cava was generated from computed tomography data and implemented into an interactive simulation. Catheter motion was imposed as boundary condition, and catheter-vessel contact was modeled with a Lagrange multiplier formulation to compute vessel deformation. The framework was tested in-vitro using a sensorized catheter with Fiber Bragg Grating and electromagnetic sensors as it was advanced through a silicone replica of the vascular anatomy. Real-time sensor read-outs fed the simulation, and the updated catheter and vessel geometries were streamed to Hololens 2. The performance and accuracy of FEM-computed vessel wall displacement were validated against experimental ground-truth obtained via stereo frames triangulation. Results: The simulated time exceeded the real temporal extent by 12% during initial navigation and by 45% when the catheter reached the most tortuous portion. Hololens 2 rendering remained stable at 35-40 frames per second. The median relative displacement error between FEM-computed and ground-truth vessel wall displacements remained below 1 mm and 2.33 mm for these two phases, respectively. Conclusion: The study demonstrates the feasibility of integrating interactive biomechanical simulation with real-time sensor data to enable continuous monitoring of catheter-vessel interactions, with mixed reality visualization serving as a user interface to support operator decision-making.

cs.HC

Augmented Reality and Human-Robot Collaboration Framework for Percutaneous Nephrolithotomy: System Design, Implementation, and Performance Metrics

During Percutaneous Nephrolithotomy (PCNL) operations, the surgeon is required to define the incision point on the patient's back, align the needle to a pre-planned path, and perform puncture operations afterward. The procedure is currently performed manually using ultrasound or fluoroscopy imaging for needle orientation, which, however, implies limited accuracy and low reproducibility. This work incorporates Augmented Reality (AR) visualization with an optical see-through head-mounted display (OST-HMD) and Human-Robot Collaboration (HRC) framework to empower the surgeon's task completion performance. In detail, Eye-to-Hand calibration, system registration, and hologram model registration are performed to realize visual guidance. A Cartesian impedance controller is used to guide the operator during the needle puncture task execution. Experiments are conducted to verify the system performance compared with conventional manual puncture procedures and a 2D monitor-based visualisation interface. The results showed that the proposed framework achieves the lowest median and standard deviation error across all the experimental groups, respectively. Furthermore, the NASA-TLX user evaluation results indicate that the proposed framework requires the lowest workload score for task completion compared to other experimental setups. The proposed framework exhibits significant potential for clinical application in the PCNL task, as it enhances the surgeon's perception capability, facilitates collision-free needle insertion path planning, and minimises errors in task completion.

cs.RO