A Monte Carlo simulation framework for investigating the effect of inter-track coupling on H$_2$O$_2$ productions at ultra-high dose rates

Background: Lower production of H$_2$O$_2$ in water is a hallmark of ultra-high dose rate (UHDR) compared to the conventional dose rate (CDR). However, the current computational models based on the predicted yield of H$_2$O$_2$ are in opposite of the experimental data. Methods: We construct an analytical model for the rate equation in the production of H$_2$O$_2$ from \ce{^{.}OH}-radicals and use it as a guide to propose a hypothetical geometrical inhomogeneity in the configuration of particles in the FLASH-UHDR beams. We perform a series of Monte Carlo (MC) simulations of the track structures for a system of charged particles impinging the medium in the form of clusters and/or bunches. Results: We demonstrate the interplay of diffusion, reaction rates, and overlaps in track-spacing attribute to a lower yield of H$_2$O$_2$ at FLASH-UHDR vs. CDR. This trend is reversed if spacing among the tracks becomes larger than a critical value, with a length scale that is proportional to the diffusion length of \ce{^{.}OH}-radicals modulated by a rate of decay due to recombination with other species, available within a track, and the space among the tracks. The latter is substantial on the suppressing of the H$_2$O$_2$ population at FLASH-UHDR relative to CDR. Conclusions: Based on our analysis of the present work, at FLASH-UHDR, the lower yield in H$_2$O$_2$ can be interpreted as a signature of bunching the particles in beams of ionizing radiation. The beams enter the medium in closely packed clusters and form inhomogeneities in the track-structure distribution. Thus the MC simulations based on the assumption of uniformly distributed tracks are unable to explain the experimental data.

physics.med-ph↗

Multi-Institutional Audit of FLASH and Conventional Dosimetry with a 3D-Printed Anatomically Realistic Mouse Phantom

We conducted a multi-institutional audit of dosimetric variability between FLASH and conventional dose rate (CONV) electron irradiations by using an anatomically realistic 3D-printed mouse phantom. A CT scan of a live mouse was used to create a 3D model of bony anatomy, lungs, and soft tissue. A dual-nozzle 3D printer was used to print the mouse phantom using acrylonitrile butadiene styrene ($~1.02 g/cm^3$) and polylactic acid ($~1.24 g/cm^3$) simultaneously to simulate soft tissue and bone densities, respectively. The lungs were printed separately using lightweight polylactic acid ($~0.64 g/cm^3$). Hounsfield units (HU) and densities were compared with the reference CT scan of the live mouse. Print-to-print reproducibility of the phantom was assessed. Three institutions were each provided a phantom, and each institution performed two replicates of irradiations at selected mouse anatomic regions. The average dose difference between FLASH and CONV dose distributions and deviation from the prescribed dose were measured with radiochromic film. Compared to the reference CT scan, CT scans of the phantom demonstrated mass density differences of $0.10 g/cm^3$ for bone, $0.12 g/cm^3$ for lung, and $0.03 g/cm^3$ for soft tissue regions. Between phantoms, the difference in HU for soft tissue and bone was <10 HU from print to print. Lung exhibited the most variation (54 HU) but minimally affected dose distribution (<0.5% dose differences between phantoms). The mean difference between FLASH and CONV from the first replicate to the second decreased from 4.3% to 1.2%, and the mean difference from the prescribed dose decreased from 3.6% to 2.5% for CONV and 6.4% to 2.7% for FLASH. The framework presented here is promising for credentialing of multi-institutional studies of FLASH preclinical research to maximize the reproducibility of biological findings.

physics.med-ph↗