Searcharxiv⌕ Search

arXiv subjects

Marie-Claude Lavallée

Publications and source records attributed to Marie-Claude Lavallée.

2 recordsLinked to original sources

Dosimetric equivalence of deep learning prostate contours after LDR brachytherapy: pre-declared margins, patient-level acceptance thresholds and the incremental predictive value of DVH indices

Background and purpose: Dose Volume Histogram (DVH) indices remain the main dose-effect metrics for toxicity prediction, but they depend on how contours were made. Inter-observer variability (IOV) is unavoidable and clinically accepted, so the question for automatic segmentation addresses equivalence: do automatic contours produce DVH errors comparable to human IOV, and can these indices predict patient-reported toxicity? Materials and methods: In 429 patients treated with iodine-125 LDR-BT monotherapy, indices from expert manual delineation were compared with a deterministic and a Bayesian nnUNet on a fixed dose distribution, by two-one-sided tests against margins set from CT contouring IOV. Logistic regression gave patient-level thresholds at 90\,\% probability of equivalence. In 380 patients, eleven DHV indices were added to a clinical baseline predicting change in International Prostate Symptom Score (IPSS) at six horizons over 5 years, with nested cross-validation, bootstrap intervals and corrected $t$-tests. Results: All cohort-level comparisons of DVH indices were declared equivalent, with no interval consuming more than 44\,\% of its equivalence margin. Individual agreement was weaker with equivalence rates from 55.9\,\% to 89.7\,\%, depending on the DVH index and automatic segmentation model. Thresholds ranged from 0.864 to 0.958 Dice. No DVH block improved IPSS prediction at any horizon. The largest improvement declared by bootstrap intervals was 0.12 IPSS points, well below the minimal clinically important difference, across all learners. Conclusion: Automatic contours matched expert dosimetry within human IOV on average, but individual equivalence requires a volume dependent quality metric threshold definition. Our DVH indices panel provides no significant predictive power for IPSS, irrespective of segmentation source and horizon.

physics.med-ph↗

Performance of an Enhanced Afterloader with Electromagnetic Tracking Capabilities for Channel Reconstruction and Error Detection

The reconstruction and error detection performance of a Flexitron research unit equipped with a special check-cable in which is integrated an EM sensor (NDI Aurora V3) that enables tracking and reconstruction capability was assessed. Reconstructions of a 24 cm long catheter were performed using two methods: continuous fixed speed check cable backward stepping and stepping through each dwell position every 1mm. The ability of the system to differentiate between two closely located (parallel) catheters was investigated by connecting catheters to the afterloader and moving it from its axis with an increment of 1mm. A robotic arm was used to move the catheter between each reconstruction. Reconstructions were obtained with a locally weighted scatter-plot smoothing algorithm. To quantify the reconstruction accuracy, distances between two catheters were computed along the reconstruction track with a 5mm step. Reconstructions of curve catheter paths were assessed through parallel and perpendicular phantom configuration to the EM field generator. Indexer length and lateral error were simulated and ROC analysis was made. Using a 50cm/s check cable speed does not allow accurate reconstruction. A slower check cable speed results in better reconstruction performance and smaller standard deviations. The optimum operating distance from the field generator (50-300mm) resulted in a lower absolute mean deviation from the expected value (0.2pm0.1mm) versus being positioned on the edge of the electromagnetic sensitive detection volume (0.6pm0.3mm). Reconstructions of curved and circular paths with a check cable speed under 5cm/s gave a 0.8pm0.5mm error, or better. All indexer and lateral shifts of 1mm were detected with a check cable speed of 2.5cm/s or under. A speed under 5cm/s is recommended for straight and curved catheter reconstructions. The check cable can also be used to detect common shift errors.

physics.med-ph↗