SearcharxivSearch

arXiv subjects

Mario Zannoni

Publications and source records attributed to Mario Zannoni.

At least 19 recordsLinked to original sources

Status and future development of the COSMOCal Project for absolute CMB polarization calibration

Cosmic Microwave Background (CMB) polarization measurements are pushing instrumental sensitivities to levels where calibration systematics become a dominant limitation. The large dynamic range between cosmological and Galactic emission prevents future experiments from relying only on diffuse sky measurements or standard celestial calibrators. To address this challenge, the COSmological Microwave Observations Calibrator (COSMOCal) project proposes an artificial calibration source deployed as a guest payload on a geostationary satellite, scheduled for launch by the Eutelsat group by 2030. This source will provide stable, well-characterized polarized microwave signals accessible to multiple ground-based observatories. In this work, we present the status of the project, the updated development timeline, and the refined scientific and technical requirements, defined with the observatories that plan to use this calibration source. Furthermore, we investigate the interplay between instrumental systematics and component separation in the presence of complex models of interstellar dust emission. We discuss in this paper how this can impact the recovery of the primordial signal, and whether residual calibration errors can degrade the performance of foreground cleaning algorithms.

astro-ph.IM

On beam characterization of ground-based CMB radio telescopes using UAV-mounted sources: application to the QUIJOTE TFGI and plans for LSPE-Strip

The Large Scale Polarization Explorer (LSPE) project, funded by the Italian Space Agency (ASI), includes the development of LSPE-Strip, a ground-based radio telescope for observing Cosmic Microwave Background (CMB) anisotropies. LSPE-Strip, nearing its construction phase, will operate from the Teide Observatory in Tenerife, employing 49 coherent polarimeters at 43 GHz to deliver critical data on CMB anisotropies and 6 channels at 95 GHz as atmospheric monitor. On-site characterization of such advanced instruments is crucial to detect possible systematic effects, such as gain fluctuations, beam distortions, and pointing errors, that can compromise performance by introducing spurious polarizations or radiation collection from unintended directions. To address these challenges, a drone-mounted Q-band test source for on-site characterization of LSPE-Strip's polarimeter array was developed. Modern Unmanned Aerial Vehicles (UAVs) offer a flexible approach for antenna pattern measurements, yet their use in high-frequency radio astronomy is not consolidated practice. In October 2022, a UAV-based measurement campaign was conducted with the TFGI instrument on the second QUIJOTE telescope in Tenerife, in collaboration with the Instituto de Astrofisica de Canarias. This pioneering effort aimed to validate UAV-based beam characterization methods and assess QUIJOTE's performance under operational conditions. Preliminary results demonstrated high measurement accuracy, leveraging QUIJOTE's dual-receiver configuration for beam validation. These findings provide valuable insights for optimizing UAV systems in preparation for LSPE-Strip's future characterization.

astro-ph.IM

PROTOCALC, A W-band polarized calibrator for CMB Telescopes: application to Simons Observatory and CLASS

Current- and next-generation Cosmic Microwave Background (CMB) experiments will measure polarization anisotropies with unprecedented sensitivities. The need for high precision in these measurements underscores the importance of gaining a comprehensive understanding of instrument properties, with a particular emphasis on the study of the beam properties and, in particular, their polarization characteristics, and the measurement of the polarization angle. In this context, a major challenge lies in the scarcity of millimeter polarized astrophysical sources with sufficient brightness and calibration knowledge to meet the stringent accuracy requirements of future CMB missions. This led to the development of a drone-borne calibration source designed for frequency band centered on approximately 90 GHz band, matching a commonly used channel in ground based CMB measurements. The PROTOtype CALibrator for Cosmology, PROTOCALC, has undergone thorough in-lab testing, and its properties have been subsequently modeled through simulation software integrated into the standard Simons Observatory (SO) analysis pipeline. Moreover, the PROTOCALC system has been tested in the field, having been deployed twice on calibration campaigns with CMB telescopes in the Atacama desert. The data collected constrain the roll angle of the source with a statistical accuracy of $0.045^\circ$.

astro-ph.IM

The LSPE-Strip Pointing Reconstruction and Star Tracker

This paper aims to describe the Pointing Reconstruction Model (PRM) and the prototype Star Tracker, which will be mounted on LSPE-Strip, a microwave Q- and W-band CMB telescope planned for installation at the "Observatorio del Teide" in Tenerife. The PRM integrates information on the instantaneous attitude provided by the telescope control system to determine the actual pointing direction and focal plane orientation of the telescope. It accounts for various non-idealities in the telescope setup, represented by eight configuration angles, which will be calibrated using the Star Tracker. Following the derivation of the PRM formalism and its implementation, we investigate the pointing errors caused by incorrect calibration of these configuration angles to validate the required 1 arcminute maximum systematic pointing error for the LSPE-Strip survey. This paper also describes the main structure and operations of the Star Tracker and presents the results of a campaign of actual sky observations conducted with a prototype. The results demonstrate a Star Tracker RMS accuracy of approximately 3 arcseconds, while systematic errors remain below 10 arcseconds. Based on these results, we analyzed the problem of reconstructing the PRM configuration angles. Two methods for intercalibrating the Star Tracker's pointing direction with respect to the focal plane's pointing direction were examined: (1) observations of planets and (2) observations of a drone carrying both an optical beacon and a radio beacon. In the first case, an intercalibration accuracy between 1/3 arcminute and 1 arcminute is achievable. In the second case, the expected intercalibration accuracy ranges from 0.25 arcminute to 1 arcminute.

astro-ph.IM

Simons Observatory: Characterization of the Large Aperture Telescope Receiver

The Simons Observatory (SO) is a ground-based cosmic microwave background (CMB) survey experiment that currently consists of three 0.42m small-aperture telescopes (SATs) and one 6m large-aperture telescope (LAT), located at an elevation of 5200m in the Atacama Desert in Chile. At the LAT's focal plane, SO will install >62,000 transition-edge sensor detectors across 13 optics tubes (OTs) within the Large Aperture Telescope Receiver (LATR), the largest cryogenic camera ever built to observe the CMB. Here we report on the validation of the LATR in the laboratory and the subsequent dark testing and validation within the LAT. We show that the LATR meets cryogenic, optical, and detector specifications required for high-sensitivity measurements of the CMB. At the time of writing, the LATR is installed in the LAT with six OTs (corresponding to >31,000 detectors), and the LAT mirrors and remaining seven OTs are undergoing development.

astro-ph.IM

Calibration of CMB Telescopes with PROTOCALC

Cosmic Microwave Background experiments need to measure polarization properties of the incoming radiation very accurately to achieve their scientific goals. As a result of that, it is necessary to properly characterize these instruments. However, there are not natural sources that can be used for this purpose. For this reason, we developed the PROTOtype CALibrator for Cosmology, PROTOCALC, which is a calibrator source designed for the 90 GHz band of these telescopes. This source is purely polarized and the direction of the polarization vector is known with an accuracy better than 0.1 deg. This source flew for the first time in May 2022 showing promising result.

astro-ph.IM

The BLAST Observatory: A Sensitivity Study for Far-IR Balloon-borne Polarimeters

Sensitive wide-field observations of polarized thermal emission from interstellar dust grains will allow astronomers to address key outstanding questions about the life cycle of matter and energy driving the formation of stars and the evolution of galaxies. Stratospheric balloon-borne telescopes can map this polarized emission at far-infrared wavelengths near the peak of the dust thermal spectrum - wavelengths that are inaccessible from the ground. In this paper we address the sensitivity achievable by a Super Pressure Balloon (SPB) polarimetry mission, using as an example the Balloon-borne Large Aperture Submillimeter Telescope (BLAST) Observatory. By launching from Wanaka, New Zealand, BLAST Observatory can obtain a 30-day flight with excellent sky coverage - overcoming limitations of past experiments that suffered from short flight duration and/or launch sites with poor coverage of nearby star-forming regions. This proposed polarimetry mission will map large regions of the sky at sub-arcminute resolution, with simultaneous observations at 175, 250, and 350 $μm$, using a total of 8274 microwave kinetic inductance detectors. Here, we describe the scientific motivation for the BLAST Observatory, the proposed implementation, and the forecasting methods used to predict its sensitivity. We also compare our forecasted experiment sensitivity with other facilities.

astro-ph.IM

Nonlinear Behavior of Josephson Traveling Wave Parametric Amplifiers

Recent advancements in quantum technologies and advanced detection experiments have underscored the pressing need for the detection of exceedingly weak signals within the microwave frequency spectrum. Addressing this challenge, the Josephson Traveling Wave Parametric Amplifier (JTWPA) has been proposed as a cryogenic front-end amplifier capable of approaching the quantum noise limit while providing a relevant bandwidth. This research is centered on a comprehensive numerical investigation of the JTWPA, without resorting to simplifications regarding the nonlinearity of the essential components. Specifically, this study focuses on a thorough examination of the system, characterized by coupled nonlinear differential equations representing all components of the device. Proper input and output signals at the device's boundaries are considered. The analysis of the output signals undergoing the parametric amplification process involves a detailed exploration of phase-space dynamics and Fourier spectral analysis of the output voltage. This study is conducted while considering the parameters ruling the response of the device under pump and signal excitations. In addition to the expected signal amplification, the findings reveal that the nonlinear nature of the system can give rise to unforeseen phenomena, depending on the system's operational conditions, which include: the generation of pump tone harmonics, modulation of the signal gain, and incommensurate frequency generation-effects that are not easily accommodated by simplistic linearized approaches

cond-mat.supr-con

Broadband parametric amplification in DARTWARS

Superconducting parametric amplifiers offer the capability to amplify feeble signals with extremely low levels of added noise, potentially reaching quantum-limited amplification. This characteristic makes them essential components in the realm of high-fidelity quantum computing and serves to propel advancements in the field of quantum sensing. In particular, Traveling-Wave Parametric Amplifiers (TWPAs) may be especially suitable for practical applications due to their multi-Gigahertz amplification bandwidth, a feature lacking in Josephson Parametric Amplifiers (JPAs), despite the latter being a more established technology. This paper presents recent developments of the DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) project, focusing on the latest prototypes of Kinetic Inductance TWPAs (KITWPAs). The project aims to develop a KITWPA capable of achieving $20\,$ dB of amplification. To enhance the production yield, the first prototypes were fabricated with half the length and expected gain of the final device. In this paper, we present the results of the characterization of one of the half-length prototypes. The measurements revealed an average amplification of approximately $9\,$dB across a $2\,$GHz bandwidth for a KITWPA spanning $17\,$mm in length.

quant-ph

Development of KI-TWPAs for the DARTWARS project

Noise at the quantum limit over a broad bandwidth is a fundamental requirement for future cryogenic experiments for neutrino mass measurements, dark matter searches and Cosmic Microwave Background (CMB) measurements as well as for fast high-fidelity read-out of superconducting qubits. In the last years, Josephson Parametric Amplifiers (JPA) have demonstrated noise levels close to the quantum limit, but due to their narrow bandwidth, only few detectors or qubits per line can be read out in parallel. An alternative and innovative solution is based on superconducting parametric amplification exploiting the travelling-wave concept. Within the DARTWARS (Detector Array Readout with Travelling Wave AmplifieRS) project, we develop Kinetic Inductance Travelling-Wave Parametric Amplifiers (KI-TWPAs) for low temperature detectors and qubit read-out. KI-TWPAs are typically operated in a threewave mixing (3WM) mode and are characterised by a high gain, a high saturation power, a large amplification bandwidth and nearly quantum limited noise performance. The goal of the DARTWARS project is to optimise the KI-TWPA design, explore new materials, and investigate alternative fabrication processes in order to enhance the overall performance of the amplifier. In this contribution we present the advancements made by the DARTWARS collaboration to produce a working prototype of a KI-TWPA, from the fabrication to the characterisation.

quant-ph

High kinetic inductance NbTiN films for quantum limited travelling wave parametric amplifiers

A wide-bandwidth and low-noise amplification chain in the microwave regime is crucial for the efficient read-out of quantum systems based on superconducting detectors, such as Microwave Kinetic Inductance Detectors (MKIDs), Transition Edge Sensors (TESs), Magnetic Microcalorimeters (MMCs), and RF cavities, as well as qubits. Kinetic Inductance Travelling Wave Parametric Amplifiers (KI-TWPAs) operated in a three-wave mixing fashion have demonstrated exceptional dynamic range and low-noise performance, approaching the quantum limit. These amplifiers can be fabricated using a single layer of a high kinetic inductance film as weakly dispersive artificial transmission lines, with the ability to control the phase-matched bandwidth through dispersion engineering. In this study, we present the optimisation of the rf sputter-deposition process of NbTiN films using a Nb80%T20 target, with the goal of achieving precise control over film characteristics, resulting in high kinetic inductance while maintaining a high transition temperature. The parameter landscape related to the different sputtering conditions, such as pressure, power, and nitrogen flow, has been explored and the film thickness has been used as a fine-tuning parameter to adjust the properties of the final NbTiN films used for the fabrication of KI-TWPAs. As a final result, we have obtained a NbTiN film with a kinetic inductance of 8.5 pH/sq which we have exploited to fabricate KI-TWPA prototype devices, showing promising amplification performance.

physics.app-ph

PROTOCALC: an artificial calibrator source for CMB telescopes

Cosmic Microwave Background experiments need to measure polarization properties of the incoming radiation very accurately to achieve their scientific goals. As a result of that, it is necessary to properly characterize these instruments. However, there are not natural sources that can be used for this purpose. For this reason, we developed the PROTOtype CALibrator for Cosmology, PROTOCALC, which is a calibrator source designed for the 90GHz band of these telescopes. This source is purely polarized and the direction of the polarization vector is known with an accuracy better than 0.1deg. This source flew for the first time in May 2022 showing promising result

astro-ph.IM

In-flight polarization angle calibration for LiteBIRD: blind challenge and cosmological implications

We present a demonstration of the in-flight polarization angle calibration for the JAXA/ISAS second strategic large class mission, LiteBIRD, and estimate its impact on the measurement of the tensor-to-scalar ratio parameter, r, using simulated data. We generate a set of simulated sky maps with CMB and polarized foreground emission, and inject instrumental noise and polarization angle offsets to the 22 (partially overlapping) LiteBIRD frequency channels. Our in-flight angle calibration relies on nulling the EB cross correlation of the polarized signal in each channel. This calibration step has been carried out by two independent groups with a blind analysis, allowing an accuracy of the order of a few arc-minutes to be reached on the estimate of the angle offsets. Both the corrected and uncorrected multi-frequency maps are propagated through the foreground cleaning step, with the goal of computing clean CMB maps. We employ two component separation algorithms, the Bayesian-Separation of Components and Residuals Estimate Tool (B-SeCRET), and the Needlet Internal Linear Combination (NILC). We find that the recovered CMB maps obtained with algorithms that do not make any assumptions about the foreground properties, such as NILC, are only mildly affected by the angle miscalibration. However, polarization angle offsets strongly bias results obtained with the parametric fitting method. Once the miscalibration angles are corrected by EB nulling prior to the component separation, both component separation algorithms result in an unbiased estimation of the r parameter. While this work is motivated by the conceptual design study for LiteBIRD, its framework can be broadly applied to any CMB polarization experiment. In particular, the combination of simulation plus blind analysis provides a robust forecast by taking into account not only detector sensitivity but also systematic effects.

astro-ph.CO

The Simons Observatory: gain, bandpass and polarization-angle calibration requirements for B-mode searches

We quantify the calibration requirements for systematic uncertainties for next-generation ground-based observatories targeting the large-angle $B$-mode polarization of the Cosmic Microwave Background, with a focus on the Simons Observatory (SO). We explore uncertainties on gain calibration, bandpass center frequencies, and polarization angles, including the frequency variation of the latter across the bandpass. We find that gain calibration and bandpass center frequencies must be known to percent levels or less to avoid biases on the tensor-to-scalar ratio $r$ on the order of $Δr\sim10^{-3}$, in line with previous findings. Polarization angles must be calibrated to the level of a few tenths of a degree, while their frequency variation between the edges of the band must be known to ${\cal O}(10)$ degrees. Given the tightness of these calibration requirements, we explore the level to which residual uncertainties on these systematics would affect the final constraints on $r$ if included in the data model and marginalized over. We find that the additional parameter freedom does not degrade the final constraints on $r$ significantly, broadening the error bar by ${\cal O}(10\%)$ at most. We validate these results by reanalyzing the latest publicly available data from the BICEP2/Keck collaboration within an extended parameter space covering both cosmological, foreground and systematic parameters. Finally, our results are discussed in light of the instrument design and calibration studies carried out within SO.

astro-ph.CO

The Simons Observatory: the Large Aperture Telescope (LAT)

The Simons Observatory (SO) is a Cosmic Microwave Background (CMB) experiment to observe the microwave sky in six frequency bands from 30GHz to 290GHz. The Observatory -- at $\sim$5200m altitude -- comprises three Small Aperture Telescopes (SATs) and one Large Aperture Telescope (LAT) at the Atacama Desert, Chile. This research note describes the design and current status of the LAT along with its future timeline.

astro-ph.IM

The Simons Observatory Large Aperture Telescope Receiver

The Simons Observatory (SO) Large Aperture Telescope Receiver (LATR) will be coupled to the Large Aperture Telescope located at an elevation of 5,200 m on Cerro Toco in Chile. The resulting instrument will produce arcminute-resolution millimeter-wave maps of half the sky with unprecedented precision. The LATR is the largest cryogenic millimeter-wave camera built to date with a diameter of 2.4 m and a length of 2.6 m. It cools 1200 kg of material to 4 K and 200 kg to 100 mk, the operating temperature of the bolometric detectors with bands centered around 27, 39, 93, 145, 225, and 280 GHz. Ultimately, the LATR will accommodate 13 40 cm diameter optics tubes, each with three detector wafers and a total of 62,000 detectors. The LATR design must simultaneously maintain the optical alignment of the system, control stray light, provide cryogenic isolation, limit thermal gradients, and minimize the time to cool the system from room temperature to 100 mK. The interplay between these competing factors poses unique challenges. We discuss the trade studies involved with the design, the final optimization, the construction, and ultimate performance of the system.

astro-ph.IM

The Simons Observatory: Metamaterial Microwave Absorber (MMA) and its Cryogenic Applications

Controlling stray light at millimeter wavelengths requires special optical design and selection of absorptive materials that should be compatible with cryogenic operating environments. While a wide selection of absorptive materials exists, these typically exhibit high indices of refraction and reflect/scatter a significant fraction of light before absorption. For many lower index materials such as commercial microwave absorbers, their applications in cryogenic environments are challenging. In this paper, we present a new tool to control stray light: metamaterial microwave absorber tiles. These tiles comprise an outer metamaterial layer that approximates a lossy gradient index anti-reflection coating. They are fabricated via injection molding commercially available carbon-loaded polyurethane (25\% by mass). The injection molding technology enables mass production at low cost. The design of these tiles is presented, along with thermal tests to 1 K. Room temperature optical measurements verify their control of reflectance to less than 1\% up to 65$\circ$ angles of incidence, and control of wide angle scattering below 0.01\%. The dielectric properties of the bulk carbon-loaded material used in the tiles is also measured at different temperatures, confirming that the material maintains similar dielectric properties down to 3 K.

astro-ph.IM

Simons Observatory Small Aperture Telescope overview

The Simons Observatory (SO) is a cosmic microwave background (CMB) experiment from the Atacama Desert in Chile comprising three small-aperture telescopes (SATs) and one large-aperture telescope (LAT). In total, SO will field over 60,000 transition-edge sensor (TES) bolometers in six spectral bands centered between 27 and 280 GHz in order to achieve the sensitivity necessary to measure or constrain numerous cosmological quantities. In this work, we focus on the SATs which are optimized to search for primordial gravitational waves that are detected as parity-odd polarization patterns called a B-modes on degree scales in the CMB. Each SAT employs a single optics tube with TES arrays operating at 100 mK. The high throughput optics system has a 42 cm aperture and a 35-degree field of view coupled to a 36 cm diameter focal plane. The optics consist of three metamaterial anti-re ection coated silicon lenses. Cryogenic ring baffles with engineered blackbody absorbers are installed in the optics tube to minimize the stray light. The entire optics tube is cooled to 1 K. A cryogenic continuously rotating half-wave plate near the sky side of the aperture stop helps to minimize the effect of atmospheric uctuations. The telescope warm baffling consists of a forebaffle, an elevation stage mounted co-moving shield, and a fixed ground shield that together control the far side-lobes and mitigates ground-synchronous systematics. We present the status of the SAT development.

astro-ph.IM