Searcharxiv⌕ Search

arXiv subjects

Mark A. Anastasio

Publications and source records attributed to Mark A. Anastasio.

At least 73 records · Page 4Linked to original sources

Approximating the Ideal Observer for joint signal detection and localization tasks by use of supervised learning methods

Medical imaging systems are commonly assessed and optimized by use of objective measures of image quality (IQ). The Ideal Observer (IO) performance has been advocated to provide a figure-of-merit for use in assessing and optimizing imaging systems because the IO sets an upper performance limit among all observers. When joint signal detection and localization tasks are considered, the IO that employs a modified generalized likelihood ratio test maximizes observer performance as characterized by the localization receiver operating characteristic (LROC) curve. Computations of likelihood ratios are analytically intractable in the majority of cases. Therefore, sampling-based methods that employ Markov-Chain Monte Carlo (MCMC) techniques have been developed to approximate the likelihood ratios. However, the applications of MCMC methods have been limited to relatively simple object models. Supervised learning-based methods that employ convolutional neural networks have been recently developed to approximate the IO for binary signal detection tasks. In this paper, the ability of supervised learning-based methods to approximate the IO for joint signal detection and localization tasks is explored. Both background-known-exactly and background-known-statistically signal detection and localization tasks are considered. The considered object models include a lumpy object model and a clustered lumpy model, and the considered measurement noise models include Laplacian noise, Gaussian noise, and mixed Poisson-Gaussian noise. The LROC curves produced by the supervised learning-based method are compared to those produced by the MCMC approach or analytical computation when feasible. The potential utility of the proposed method for computing objective measures of IQ for optimizing imaging system performance is explored.

eess.SP↗

Learning stochastic object models from medical imaging measurements using Progressively-Growing AmbientGANs

It has been advocated that medical imaging systems and reconstruction algorithms should be assessed and optimized by use of objective measures of image quality that quantify the performance of an observer at specific diagnostic tasks. One important source of variability that can significantly limit observer performance is variation in the objects to-be-imaged. This source of variability can be described by stochastic object models (SOMs). A SOM is a generative model that can be employed to establish an ensemble of to-be-imaged objects with prescribed statistical properties. In order to accurately model variations in anatomical structures and object textures, it is desirable to establish SOMs from experimental imaging measurements acquired by use of a well-characterized imaging system. Deep generative neural networks, such as generative adversarial networks (GANs) hold great potential for this task. However, conventional GANs are typically trained by use of reconstructed images that are influenced by the effects of measurement noise and the reconstruction process. To circumvent this, an AmbientGAN has been proposed that augments a GAN with a measurement operator. However, the original AmbientGAN could not immediately benefit from modern training procedures, such as progressive growing, which limited its ability to be applied to realistically sized medical image data. To circumvent this, in this work, a new Progressive Growing AmbientGAN (ProAmGAN) strategy is developed for establishing SOMs from medical imaging measurements. Stylized numerical studies corresponding to common medical imaging modalities are conducted to demonstrate and validate the proposed method for establishing SOMs.

eess.IV↗

Approximating the Hotelling Observer with Autoencoder-Learned Efficient Channels for Binary Signal Detection Tasks

The objective assessment of image quality (IQ) has been advocated for the analysis and optimization of medical imaging systems. One method of obtaining such IQ metrics is through a mathematical observer. The Bayesian ideal observer is optimal by definition for signal detection tasks, but is frequently both intractable and non-linear. As an alternative, linear observers are sometimes used for task-based image quality assessment. The optimal linear observer is the Hotelling observer (HO). The computational cost of calculating the HO increases with image size, making a reduction in the dimensionality of the data desirable. Channelized methods have become popular for this purpose, and many competing methods are available for computing efficient channels. In this work, a novel method for learning channels using an autoencoder (AE) is presented. AEs are a type of artificial neural network (ANN) that are frequently employed to learn concise representations of data to reduce dimensionality. Modifying the traditional AE loss function to focus on task-relevant information permits the development of efficient AE-channels. These AE-channels were trained and tested on a variety of signal shapes and backgrounds to evaluate their performance. In the experiments, the AE-learned channels were competitive with and frequently outperformed other state-of-the-art methods for approximating the HO. The performance gains were greatest for the datasets with a small number of training images and noisy estimates of the signal image. Overall, AEs are demonstrated to be competitive with state-of-the-art methods for generating efficient channels for the HO and can have superior performance on small datasets.

eess.SP↗

Learning Numerical Observers using Unsupervised Domain Adaptation

Medical imaging systems are commonly assessed by use of objective image quality measures. Supervised deep learning methods have been investigated to implement numerical observers for task-based image quality assessment. However, labeling large amounts of experimental data to train deep neural networks is tedious, expensive, and prone to subjective errors. Computer-simulated image data can potentially be employed to circumvent these issues; however, it is often difficult to computationally model complicated anatomical structures, noise sources, and the response of real world imaging systems. Hence, simulated image data will generally possess physical and statistical differences from the experimental image data they seek to emulate. Within the context of machine learning, these differences between the sets of two images is referred to as domain shift. In this study, we propose and investigate the use of an adversarial domain adaptation method to mitigate the deleterious effects of domain shift between simulated and experimental image data for deep learning-based numerical observers (DL-NOs) that are trained on simulated images but applied to experimental ones. In the proposed method, a DL-NO will initially be trained on computer-simulated image data and subsequently adapted for use with experimental image data, without the need for any labeled experimental images. As a proof of concept, a binary signal detection task is considered. The success of this strategy as a function of the degree of domain shift present between the simulated and experimental image data is investigated.

cs.CV↗

Medical image reconstruction with image-adaptive priors learned by use of generative adversarial networks

Medical image reconstruction is typically an ill-posed inverse problem. In order to address such ill-posed problems, the prior distribution of the sought after object property is usually incorporated by means of some sparsity-promoting regularization. Recently, prior distributions for images estimated using generative adversarial networks (GANs) have shown great promise in regularizing some of these image reconstruction problems. In this work, we apply an image-adaptive GAN-based reconstruction method (IAGAN) to reconstruct high fidelity images from incomplete medical imaging data. It is observed that the IAGAN method can potentially recover fine structures in the object that are relevant for medical diagnosis but may be oversmoothed in reconstructions with traditional sparsity-promoting regularization.

eess.IV↗

Progressively-Growing AmbientGANs For Learning Stochastic Object Models From Imaging Measurements

The objective optimization of medical imaging systems requires full characterization of all sources of randomness in the measured data, which includes the variability within the ensemble of objects to-be-imaged. This can be accomplished by establishing a stochastic object model (SOM) that describes the variability in the class of objects to-be-imaged. Generative adversarial networks (GANs) can be potentially useful to establish SOMs because they hold great promise to learn generative models that describe the variability within an ensemble of training data. However, because medical imaging systems record imaging measurements that are noisy and indirect representations of object properties, GANs cannot be directly applied to establish stochastic models of objects to-be-imaged. To address this issue, an augmented GAN architecture named AmbientGAN was developed to establish SOMs from noisy and indirect measurement data. However, because the adversarial training can be unstable, the applicability of the AmbientGAN can be potentially limited. In this work, we propose a novel training strategy---Progressive Growing of AmbientGANs (ProAGAN)---to stabilize the training of AmbientGANs for establishing SOMs from noisy and indirect imaging measurements. An idealized magnetic resonance (MR) imaging system and clinical MR brain images are considered. The proposed methodology is evaluated by comparing signal detection performance computed by use of ProAGAN-generated synthetic images and images that depict the true object properties.

eess.IV↗

Markov-Chain Monte Carlo Approximation of the Ideal Observer using Generative Adversarial Networks

The Ideal Observer (IO) performance has been advocated when optimizing medical imaging systems for signal detection tasks. However, analytical computation of the IO test statistic is generally intractable. To approximate the IO test statistic, sampling-based methods that employ Markov-Chain Monte Carlo (MCMC) techniques have been developed. However, current applications of MCMC techniques have been limited to several object models such as a lumpy object model and a binary texture model, and it remains unclear how MCMC methods can be implemented with other more sophisticated object models. Deep learning methods that employ generative adversarial networks (GANs) hold great promise to learn stochastic object models (SOMs) from image data. In this study, we described a method to approximate the IO by applying MCMC techniques to SOMs learned by use of GANs. The proposed method can be employed with arbitrary object models that can be learned by use of GANs, thereby the domain of applicability of MCMC techniques for approximating the IO performance is extended. In this study, both signal-known-exactly (SKE) and signal-known-statistically (SKS) binary signal detection tasks are considered. The IO performance computed by the proposed method is compared to that computed by the conventional MCMC method. The advantages of the proposed method are discussed.

eess.SP↗

Approximating the Ideal Observer and Hotelling Observer for binary signal detection tasks by use of supervised learning methods

It is widely accepted that optimization of medical imaging system performance should be guided by task-based measures of image quality (IQ). Task-based measures of IQ quantify the ability of an observer to perform a specific task such as detection or estimation of a signal (e.g., a tumor). For binary signal detection tasks, the Bayesian Ideal Observer (IO) sets an upper limit of observer performance and has been advocated for use in optimizing medical imaging systems and data-acquisition designs. Except in special cases, determination of the IO test statistic is analytically intractable. Markov-chain Monte Carlo (MCMC) techniques can be employed to approximate IO detection performance, but their reported applications have been limited to relatively simple object models. In cases where the IO test statistic is difficult to compute, the Hotelling Observer (HO) can be employed. To compute the HO test statistic, potentially large covariance matrices must be accurately estimated and subsequently inverted, which can present computational challenges. This work investigates supervised learning-based methodologies for approximating the IO and HO test statistics. Convolutional neural networks (CNNs) and single-layer neural networks (SLNNs) are employed to approximate the IO and HO test statistics, respectively. Numerical simulations were conducted for both signal-known-exactly (SKE) and signal-known-statistically (SKS) signal detection tasks. The performances of the supervised learning methods are assessed via receiver operating characteristic (ROC) analysis and the results are compared to those produced by use of traditional numerical methods or analytical calculations when feasible. The potential advantages of the proposed supervised learning approaches for approximating the IO and HO test statistics are discussed.

eess.SP↗

Reconstruction-Aware Imaging System Ranking by use of a Sparsity-Driven Numerical Observer Enabled by Variational Bayesian Inference

It is widely accepted that optimization of imaging system performance should be guided by task-based measures of image quality (IQ). It has been advocated that imaging hardware or data-acquisition designs should be optimized by use of an ideal observer (IO) that exploits full statistical knowledge of the measurement noise and class of objects to be imaged, without consideration of the reconstruction method. In practice, accurate and tractable models of the complete object statistics are often difficult to determine. Moreover, in imaging systems that employ compressive sensing concepts, imaging hardware and sparse image reconstruction are innately coupled technologies. In this work, a sparsity-driven observer (SDO) that can be employed to optimize hardware by use of a stochastic object model describing object sparsity is described and investigated. The SDO and sparse reconstruction method can therefore be "matched" in the sense that they both utilize the same statistical information regarding the class of objects to be imaged. To efficiently compute the SDO test statistic, computational tools developed recently for variational Bayesian inference with sparse linear models are adopted. The use of the SDO to rank data-acquisition designs in a stylized example as motivated by magnetic resonance imaging (MRI) is demonstrated. This study reveals that the SDO can produce rankings that are consistent with visual assessments of the reconstructed images but different from those produced by use of the traditionally employed Hotelling observer (HO).

cs.CV↗

A survey of computational frameworks for solving the acoustic inverse problem in three-dimensional photoacoustic computed tomography

Photoacoustic computed tomography (PACT), also known as optoacoustic tomography, is an emerging imaging technique that holds great promise for biomedical imaging. PACT is a hybrid imaging method that can exploit the strong endogenous contrast of optical methods along with the high spatial resolution of ultrasound methods. In its canonical form that is addressed in this article, PACT seeks to estimate the photoacoustically-induced initial pressure distribution within the object. Image reconstruction methods are employed to solve the acoustic inverse problem associated with the image formation process. When an idealized imaging scenario is considered, analytic solutions to the PACT inverse problem are available; however, in practice, numerous challenges exist that are more readily addressed within an optimization-based, or iterative, image reconstruction framework. In this article, the PACT image reconstruction problem is reviewed within the context of modern optimization-based image reconstruction methodologies. Imaging models that relate the measured photoacoustic wavefields to the sought-after object function are described in their continuous and discrete forms. The basic principles of optimization-based image reconstruction from discrete PACT measurement data are presented, which includes a review of methods for modeling the PACT measurement system response and other important physical factors. Non-conventional formulations of the PACT image reconstruction problem, in which acoustic parameters of the medium are concurrently estimated along with the PACT image, are also introduced and reviewed.

physics.med-ph↗

A forward-adjoint operator pair based on the elastic wave equation for use in transcranial photoacoustic tomography

Photoacoustic computed tomography (PACT) is an emerging imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the photoacoustically induced initial pressure distribution within tissue. The PACT reconstruction problem corresponds to an inverse source problem in which the initial pressure distribution is recovered from measurements of the radiated wavefield. A major challenge in transcranial PACT brain imaging is compensation for aberrations in the measured data due to the presence of the skull. Ultrasonic waves undergo absorption, scattering and longitudinal-to-shear wave mode conversion as they propagate through the skull. To properly account for these effects, a wave-equation-based inversion method should be employed that can model the heterogeneous elastic properties of the skull. In this work, a forward model based on a finite-difference time-domain discretization of the three-dimensional elastic wave equation is established and a procedure for computing the corresponding adjoint of the forward operator is presented. Massively parallel implementations of these operators employing multiple graphics processing units (GPUs) are also developed. The developed numerical framework is validated and investigated in computer-simulation and experimental phantom studies whose designs are motivated by transcranial PACT applications.

physics.med-ph↗

Mitigation of artifacts due to isolated acoustic heterogeneities in photoacoustic computed tomography using a variable data truncation-based reconstruction method

Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. If the object possesses spatially variant acoustic properties that are unaccounted for by the reconstruction method, the estimated image can contain distortions. While reconstruction methods have recently been developed to compensate for this effect, they generally require the object's acoustic properties to be known a priori. To circumvent the need for detailed information regarding an object's acoustic properties, we previously proposed a half-time reconstruction method for PACT. A half-time reconstruction method estimates the PACT image from a data set that has been temporally truncated to exclude the data components that have been strongly aberrated. However, this method can be improved upon when the approximate sizes and locations of isolated heterogeneous structures, such as bones or gas pockets, are known. To address this, we investigate PACT reconstruction methods that are based on a variable data truncation (VDT) approach. The VDT approach represents a generalization of the half-time approach, in which the degree of temporal truncation for each measurement is determined by the distance between the corresponding ultrasonic transducer location and the nearest known bone or gas void location. Computer-simulated and experimental data are employed to demonstrate the effectiveness of the approach in mitigating artifacts due to acoustic heterogeneities.

physics.med-ph↗

Deep Learning-Guided Image Reconstruction from Incomplete Data

An approach to incorporate deep learning within an iterative image reconstruction framework to reconstruct images from severely incomplete measurement data is presented. Specifically, we utilize a convolutional neural network (CNN) as a quasi-projection operator within a least squares minimization procedure. The CNN is trained to encode high level information about the class of images being imaged; this information is utilized to mitigate artifacts in intermediate images produced by use of an iterative method. The structure of the method was inspired by the proximal gradient descent method, where the proximal operator is replaced by a deep CNN and the gradient descent step is generalized by use of a linear reconstruction operator. It is demonstrated that this approach improves image quality for several cases of limited-view image reconstruction and that using a CNN in an iterative method increases performance compared to conventional image reconstruction approaches. We test our method on several limited-view image reconstruction problems. Qualitative and quantitative results demonstrate state-of-the-art performance.

cs.CV↗

Regularized Dual Averaging Image Reconstruction for Full-Wave Ultrasound Computed Tomography

Ultrasound computed tomography (USCT) holds great promise for breast cancer screening. Waveform inversion-based image reconstruction methods account for higher order diffraction effects and can produce high-resolution USCT images, but are computationally demanding. Recently, a source encoding technique was combined with stochastic gradient descent to greatly reduce image reconstruction times. However, this method bundles the stochastic data fidelity term with the deterministic regularization term. This limitation can be overcome by replacing stochastic gradient descent (SGD) with a structured optimization method, such as the regularized dual averaging (RDA) method, that exploits knowledge of the composition of the cost function. In this work, the dual averaging method is combined with source encoding techniques to improve the effectiveness of regularization while maintaining the reduced reconstruction times afforded by source encoding. It is demonstrated that each iteration can be decomposed into a gradient descent step based on the data fidelity term and a proximal update step corresponding to the regularization term. Furthermore, the regularization term is never explicitly differentiated, allowing non-smooth regularization penalties to be naturally incorporated. The wave equation is solved by use of a time-domain method. The effectiveness of this approach is demonstrated through computer-simulation and experimental studies. The results suggest that the dual averaging method can produce images with less noise and comparable resolution to those obtained by use of stochastic gradient descent.

physics.med-ph↗

Joint Reconstruction of Absorbed Optical Energy Density and Sound Speed Distribution in Photoacoustic Computed Tomography: A numerical Investigation

Photoacoustic computed tomography (PACT) is a rapidly emerging bioimaging modality that seeks to reconstruct an estimate of the absorbed optical energy density within an object. Conventional PACT image reconstruction methods assume a constant speed-of-sound (SOS), which can result in image artifacts when acoustic aberrations are significant. It has been demonstrated that incorporating knowledge of an object's SOS distribution into a PACT image reconstruction method can improve image quality. However, in many cases, the SOS distribution cannot be accurately and/or conveniently estimated prior to the PACT experiment. Because variations in the SOS distribution induce aberrations in the measured photoacoustic wavefields, certain information regarding an object's SOS distribution is encoded in the PACT measurement data. Based on this observation, a joint reconstruction (JR) problem has been proposed in which the SOS distribution is concurrently estimated along with the sought-after absorbed optical energy density from the photoacoustic measurement data. A broad understanding of the extent to which the JR problem can be accurately and reliably solved has not been reported. In this work, a series of numerical experiments is described that elucidate some important properties of the JR problem that pertain to its practical feasibility. To accomplish this, an optimization-based formulation of the JR problem is developed that yields a non-linear iterative algorithm that alternatingly updates the two image estimates. Heuristic analytic insights into the reconstruction problem are also provided. These results confirm the ill-conditioned nature of the joint reconstruction problem that will present significant challenges for practical applications.

physics.med-ph↗

A constrained variable projection reconstruction method for photoacoustic computed tomography without accurate knowledge of transducer responses

Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. When the imaging system employs conventional piezoelectric ultrasonic transducers, the ideal photoacoustic (PA) signals are degraded by the transducers' acousto-electric impulse responses (EIRs) during the measurement process. If unaccounted for, this can degrade the accuracy of the reconstructed image. In principle, the effect of the EIRs on the measured PA signals can be ameliorated via deconvolution; images can be reconstructed subsequently by application of a reconstruction method that assumes an idealized EIR. Alternatively, the effect of the EIR can be incorporated into an imaging model and implicitly compensated for during reconstruction. In either case, the efficacy of the correction can be limited by errors in the assumed EIRs. In this work, a joint optimization approach to PACT image reconstruction is proposed for mitigating errors in reconstructed images that are caused by use of an inaccurate EIR. The method exploits the bi-linear nature of the imaging model and seeks to refine the measured EIR during the process of reconstructing the sought-after absorbed optical energy density. Computer-simulation and experimental studies are conducted to investigate the numerical properties of the method and demonstrate its value for mitigating image distortions and enhancing the visibility of fine structures.

physics.med-ph↗

Waveform Inversion with Source Encoding for Breast Sound Speed Reconstruction in Ultrasound Computed Tomography

Ultrasound computed tomography (USCT) holds great promise for improving the detection and management of breast cancer. Because they are based on the acoustic wave equation, waveform inversion-based reconstruction methods can produce images that possess improved spatial resolution properties over those produced by ray-based methods. However, waveform inversion methods are computationally demanding and have not been applied widely in USCT breast imaging. In this work, source encoding concepts are employed to develop an accelerated USCT reconstruction method that circumvents the large computational burden of conventional waveform inversion methods. This method, referred to as the waveform inversion with source encoding (WISE) method, encodes the measurement data using a random encoding vector and determines an estimate of the sound speed distribution by solving a stochastic optimization problem by use of a stochastic gradient descent algorithm. Both computer-simulation and experimental phantom studies are conducted to demonstrate the use of the WISE method. The results suggest that the WISE method maintains the high spatial resolution of waveform inversion methods while significantly reducing the computational burden.

physics.med-ph↗

Accelerating Image Reconstruction in Three-Dimensional Optoacoustic Tomography on Graphics Processing Units

Purpose: Optoacoustic tomography (OAT) is inherently a three-dimensional (3D) inverse problem. However, most studies of OAT image reconstruction still employ two-dimensional (2D) imaging models. One important reason is because 3D image reconstruction is computationally burdensome. The aim of this work is to accelerate existing image reconstruction algorithms for 3D OAT by use of parallel programming techniques. Methods: Parallelization strategies are proposed to accelerate a filtered backprojection (FBP) algorithm and two different pairs of projection/backprojection operations that correspond to two different numerical imaging models. The algorithms are designed to fully exploit the parallel computing power of graphic processing units (GPUs). In order to evaluate the parallelization strategies for the projection/backprojection pairs, an iterative image reconstruction algorithm is implemented. Computer-simulation and experimental studies are conducted to investigate the computational efficiency and numerical accuracy of the developed algorithms. Results: The GPU implementations improve the computational efficiency by factors of 1, 000, 125, and 250 for the FBP algorithm and the two pairs of projection/backprojection operators, respectively. Accurate images are reconstructed by use of the FBP and iterative image reconstruction algorithms from both computer-simulated and experimental data. Conclusions: Parallelization strategies for 3D OAT image reconstruction are proposed for the first time. These GPU-based implementations significantly reduce the computational time for 3D image reconstruction, complementing our earlier work on 3D OAT iterative image reconstruction.

physics.med-ph↗