SearcharxivSearch

arXiv subjects

Mark Muzi

Publications and source records attributed to Mark Muzi.

2 recordsLinked to original sources

Determination of unscaled blood input for human dynamic FDG brain PET

Objectives: Many existing techniques for the non-invasive quantification of the blood input function in dynamic FDG-PET imaging require strong historical information or user input. The technique proposed in this work utilizes the assumption that a dynamic PET scan can be modeled by the Patlak plot to determine an unscaled blood input function. Materials and Methods: The time activity curve (TAC) for each voxel in a dynamic image can be considered as an n-dimensional vector. In this context, a TAC follows the Patlak plot if and only if the TAC is a linear combination of the blood input function and the integral of the blood input function. Given a set of TACs which follow the Patlak plot, we can thus use PCA to determine a basis which spans the same vector space as the blood input function and the integral of the blood input function. We then seek to find two TACs in this vector space which best satisfy that the estimated anti-derivative of one of the TACs is close to the other TAC; such TACs are candidates for the blood input function and the integral of the blood input function. We were able to construct a low (2) dimensional optimization problem to find such TACs. Results: We applied our results to obtain predicted blood input functions and Ki maps for twelve normal subjects. Scaling the predicted blood input function to best match the ground truth, we achieved an average SSE of $0.042 \pm 0.032$ and an average DTW distance of $0.141 \pm 0.053$. Matching the means of the predicted and ground truth Ki maps, we achieved an average MAPE of $2.539 \pm 0.928$ and an average SSIM of $0.991 \pm 0.005$. Conclusion: While not often viewed as such, the assumption that some dynamic data follows a kinetic model gives strong prior information. In the case of the Patlak plot, we can use this assumption to estimate an unscaled blood input function and unscaled Ki map.

physics.med-ph

Voxel-level mapping of tracer kinetics in PET studies: A statistical approach emphasizing tissue life tables

Most radiotracers used in dynamic positron emission tomography (PET) scanning act in a linear time-invariant fashion so that the measured time-course data are a convolution between the time course of the tracer in the arterial supply and the local tissue impulse response, known as the tissue residue function. In statistical terms the residue is a life table for the transit time of injected radiotracer atoms. The residue provides a description of the tracer kinetic information measurable by a dynamic PET scan. Decomposition of the residue function allows separation of rapid vascular kinetics from slower blood-tissue exchanges and tissue retention. For voxel-level analysis, we propose that residues be modeled by mixtures of nonparametrically derived basis residues obtained by segmentation of the full data volume. Spatial and temporal aspects of diagnostics associated with voxel-level model fitting are emphasized. Illustrative examples, some involving cancer imaging studies, are presented. Data from cerebral PET scanning with $^{18}$F fluoro-deoxyglucose (FDG) and $^{15}$O water (H2O) in normal subjects is used to evaluate the approach. Cross-validation is used to make regional comparisons between residues estimated using adaptive mixture models with more conventional compartmental modeling techniques. Simulations studies are used to theoretically examine mean square error performance and to explore the benefit of voxel-level analysis when the primary interest is a statistical summary of regional kinetics. The work highlights the contribution that multivariate analysis tools and life-table concepts can make in the recovery of local metabolic information from dynamic PET studies, particularly ones in which the assumptions of compartmental-like models, with residues that are sums of exponentials, might not be certain.

stat.AP