SearcharxivSearch

arXiv subjects

Markus Griedel

Publications and source records attributed to Markus Griedel.

3 recordsLinked to original sources

Low-loss Material for Infrared Protection of Cryogenic Quantum Applications

The fragile quantum states of low-temperature quantum applications require protection from infrared radiation caused by higher-temperature stages or other sources. We propose a material system that can efficiently block radiation up to the optical range while transmitting photons at low gigahertz frequencies. It is based on the effect that incident photons are strongly scattered when their wavelength is comparable to the size of particles embedded in a weakly absorbing medium (Mie-scattering). The goal of this work is to tailor the absorption and transmission spectrum of an non-magnetic epoxy resin containing sapphire spheres by simulating its dependence on the size distribution. Additionally, we fabricate several material compositions, characterize them, as well as other materials, at optical, infrared, and gigahertz frequencies. In the infrared region (stop band) the attenuation of the Mie-scattering optimized material is high and comparable to that of other commonly used filter materials. At gigahertz frequencies (pass-band), the prototype filter exhibits a high transmission at millikelvin temperatures, with an insertion loss of less than $0.4\,$dB below $10\,$GHz.

cond-mat.supr-con

Improved limit on the effective electron neutrino mass with the ECHo-1k experiment

The effective electron neutrino mass can be determined by analyzing the endpoint region of the $^{163}$Ho electron capture spectrum, provided a measurement with high energy resolution and high statistics using calorimetric techniques. Here, the Electron Capture in $^{163}$Ho collaboration, ECHo, presents an analysis of the most precise $^{163}$Ho spectrum currently available, obtained with the ECHo-1k experiment and comprising about 200 million events. A very low background rate of $B=9.1(1.3)\times 10^{-6}$ /eV/pixel/day was achieved allowing for a reliable analysis of the endpoint region. The derived endpoint energy $Q = 2862(4)$ eV is in excellent agreement with the one independently determined via Penning-trap mass spectrometry of $Q=2863.2(6)$ eV [1]. The upper limit of the effective electron neutrino mass is improved by almost a factor 2 compared to the lowest current value [2], reaching $m_{\nu_\mathrm{e}} < 15 $ eV/c${^2}$ (90\% credible interval).

hep-ex

Development and characterisation of high-resolution microcalorimeter detectors for the ECHo-100k experiment

The goal of the ECHo experiment is a direct determination of the absolute scale of the neutrino mass by the analysis of the end-point region of the Ho-163 electron capture (EC) spectrum. The results of the first phase of the experiment, ECHo-1k, have paved the way for the current phase, ECHo-100k, which aims at a sensitivity below 2 eV on the effective electron neutrino mass. In order to reach this goal, a new generation of high-resolution magnetic microcalorimeters with embedded Ho-163 have been developed and characterised. The design has been optimised to meet all the challenging requirements of the ECHo-100k experimental phase, such as excellent energy resolution, wafer scale implantation and multi-chip operation with multiplexing read-out. We present the optimisation studies, the final design of the detector array and the first characterisation studies. The results demonstrate that the detectors fully match and even surpass the requirements for the current experimental phase, ECHo-100k.

physics.ins-det