Searcharxiv⌕ Search

arXiv subjects

Marlene J. E. Mayer

Publications and source records attributed to Marlene J. E. Mayer.

2 recordsLinked to original sources

Prenatal Stress Detection from Electrocardiography Using Self-Supervised Deep Learning: Development and External Validation

Prenatal psychological stress affects 15-25% of pregnancies and increases risks of preterm birth, low birth weight, and adverse neurodevelopmental outcomes. Current screening relies on subjective questionnaires (PSS-10), limiting continuous monitoring. We developed deep learning models for stress detection from electrocardiography (ECG) using the FELICITy 1 cohort (151 pregnant women, 32-38 weeks gestation). A ResNet-34 encoder was pretrained via SimCLR contrastive learning on 40,692 ECG segments per subject. Multi-layer feature extraction enabled binary classification and continuous PSS prediction across maternal (mECG), fetal (fECG), and abdominal ECG (aECG). External validation used the FELICITy 2 RCT (28 subjects, different ECG device, yoga intervention vs. control). On FELICITy 1 (5-fold CV): mECG 98.6% accuracy (R2=0.88, MAE=1.90), fECG 99.8% (R2=0.95, MAE=1.19), aECG 95.5% (R2=0.75, MAE=2.80). External validation on FELICITy 2: mECG 77.3% accuracy (R2=0.62, MAE=3.54, AUC=0.826), aECG 63.6% (R2=0.29, AUC=0.705). Signal quality-based channel selection outperformed all-channel averaging (+12% R2 improvement). Mixed-effects models detected a significant intervention response (p=0.041). Self-supervised deep learning on pregnancy ECG enables accurate, objective stress assessment, with multi-layer feature extraction substantially outperforming single embedding approaches.

q-bio.QM↗

Inter-Electrode Pulse Wave Velocity: A Direct Method for Maternal Arterial Stiffness Assessment During Pregnancy Using Multi-Channel ECG

Objective: To validate a novel inter-electrode pulse wave velocity (PWV) method that measures pulse propagation between ECG electrodes without left ventricular ejection time (LVET) estimation. Methods: We analyzed 43 three-channel ECG recordings (1000 Hz) from the FELICITy 2 cohort (approximately 19 and 35 weeks gestation). R-peaks were independently detected per channel using an ensemble approach. Time lags (Delta t) between matched R-peaks across electrode pairs were used to compute PWV as PWV = L / Delta t, where L is effective inter-electrode distance. Three channel pairs yielded independent PWV estimates. Temporal stability was assessed using sliding windows (1-15 minutes). To test whether Delta t reflects morphology or vascular propagation, we evaluated three QRS fiducials (R-peak, QRS onset, maximum dV/dt) and two bandpass filters (0.5-40 and 0.5-100 Hz). Longitudinal changes were compared between control (n=24) and yoga (n=20) groups. Results: PWV values were physiologically plausible and consistent with aortic PWV (5-10 m/s): control 7.40 +/- 1.51 vs 6.98 +/- 1.63 m/s; yoga 7.10 +/- 2.15 vs 8.16 +/- 0.91 m/s (early vs late pregnancy). PWV stabilized at 5 minutes (coefficient of variation 12.3 percent), with 2.6- to 5.2-fold lower variability than heart rate and heart rate variability. Inter-electrode delays (15-27 ms) persisted across fiducials and were minimally affected by filter settings (change -8.5 percent, not significant), arguing against purely morphological distortion; PWV remained within 6.8-9.1 m/s. Preliminary group trends differed (control -5.7 percent, yoga +14.9 percent; interaction p=0.07). Conclusions: Inter-electrode PWV enables direct spatial assessment of pulse propagation with physiologically valid values, is robust to fiducial and filtering choices, and shows promise for pregnancy-related arterial stiffness assessment with standard multi-channel ECG.

physics.med-ph↗