Searcharxiv⌕ Search

arXiv subjects

Marlis-Madeleine La Caria

Publications and source records attributed to Marlis-Madeleine La Caria.

2 recordsLinked to original sources

Performance Testing of a Large-Format Reflection Grating Prototype for a Suborbital Rocket Payload

The soft X-ray grating spectrometer on board the Off-plane Grating Rocket Experiment (OGRE) hopes to achieve the highest resolution soft X-ray spectrum of an astrophysical object when it is launched via suborbital rocket. Paramount to the success of the spectrometer are the performance of the $>250$ reflection gratings populating its reflection grating assembly. To test current grating fabrication capabilities, a grating prototype for the payload was fabricated via electron-beam lithography at The Pennsylvania State University's Materials Research Institute and was subsequently tested for performance at Max Planck Institute for Extraterrestrial Physics' PANTER X-ray Test Facility. Bayesian modeling of the resulting data via Markov chain Monte Carlo (MCMC) sampling indicated that the grating achieved the OGRE single-grating resolution requirement of $R_{g}(λ/Δλ)>4500$ at the 94% confidence level. The resulting $R_g$ posterior probability distribution suggests that this confidence level is likely a conservative estimate though, since only a finite $R_g$ parameter space was sampled and the model could not constrain the upper bound of $R_g$ to less than infinity. Raytrace simulations of the system found that the observed data can be reproduced with a grating performing at $R_g=\infty$. It is therefore postulated that the behavior of the obtained $R_g$ posterior probability distribution can be explained by a finite measurement limit of the system and not a finite limit on $R_g$. Implications of these results and improvements to the test setup are discussed.

astro-ph.IM↗

Calibration of X-ray telescope prototypes at PANTER

We report a ground X-ray calibration of two X-ray telescope prototypes at the PANTER X-ray Test Facility, of the Max-Planck-Institute for Extraterrestrial Physics, in Neuried, Germany. The X-ray telescope prototypes were developed by the Institute of Precision Optical Engineering (IPOE) of Tongji University, in a conical Wolter-I configuration, using thermal glass slumping technology. Prototype #1 with 3 layers and Prototype #2 with 21 layers were tested to assess the prototypes' on-axis imaging performance. The measurement of Prototype #1 indicates a Half Power Diameter (HPD) of 82" at 1.49 keV. As for Prototype #2, we performed more comprehensive measurements of on-axis angular resolution and effective area at several energies ranging from 0.5-10 keV. The HPD and effective area are 111" and 39 cm^2 at 1.49 keV, respectively, at which energy the on-axis performance of the prototypes is our greatest concern.

astro-ph.IM↗