Searcharxiv⌕ Search

arXiv subjects

Marshall W. Bautz

Publications and source records attributed to Marshall W. Bautz.

At least 37 records · Page 2Linked to original sources

Continued developments in X-ray speed reading: fast, low noise readout for next-generation wide-field imagers

Future strategic X-ray astronomy missions will require unprecedentedly sensitive wide-field imagers providing high frame rates, low readout noise and excellent soft energy response. To meet these needs, our team is employing a multi-pronged approach to advance several key areas of technology. Our first focus is on advanced readout electronics, specifically integrated electronics, where we are collaborating on the VERITAS readout chip for the Athena Wide Field Imager, and have developed the Multi-Channel Readout Chip (MCRC), which enables fast readout and high frame rates for MIT-LL JFET (junction field effect transistor) CCDs. Second, we are contributing to novel detector development, specifically the SiSeRO (Single electron Sensitive Read Out) devices fabricated at MIT Lincoln Laboratory, and their advanced readout, to achieve sub-electron noise performance. Hardware components set the stage for performance, but their efficient utilization relies on software and algorithms for signal and event processing. Our group is developing digital waveform filtering and AI methods to augment detector performance, including enhanced particle background screening and improved event characterization. All of these efforts make use of an efficient, new X-ray beamline facility at Stanford, where components and concepts can be tested and characterized.

astro-ph.IM↗

Demonstrating sub-electron noise performance in Single electron Sensitive Readout (SiSeRO) devices

Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detection technology that can, in principle, provide significantly greater responsivity and improved noise performance than traditional charge coupled device (CCD) readout circuitry. The SiSeRO, developed by MIT Lincoln Laboratory, uses a p-MOSFET transistor with a depleted back-gate region under the transistor channel; as charge is transferred into the back gate region, the transistor current is modulated. With our first generation SiSeRO devices, we previously achieved a responsivity of around 800 pA per electron, an equivalent noise charge (ENC) of 4.5 electrons root mean square (RMS), and a full width at half maximum (FWHM) spectral resolution of 130 eV at 5.9 keV, at a readout speed of 625 Kpixel/s and for a detector temperature of 250 K. Importantly, since the charge signal remains unaffected by the SiSeRO readout process, we have also been able to implement Repetitive Non-Destructive Readout (RNDR), achieving an improved ENC performance. In this paper, we demonstrate sub-electron noise sensitivity with these devices, utilizing an enhanced test setup optimized for RNDR measurements, with excellent temperature control, improved readout circuitry, and advanced digital filtering techniques. We are currently fabricating new SiSeRO detectors with more sensitive and RNDR-optimized amplifier designs, which will help mature the SiSeRO technology in the future and eventually lead to the pathway to develop active pixel sensor (APS) arrays using sensitive SiSeRO amplifiers on each pixel. Active pixel devices with sub-electron sensitivity and fast readout present an exciting option for next generation, large area astronomical X-ray telescopes requiring fast, low-noise megapixel imagers.

astro-ph.IM↗

X-ray speed reading with the MCRC: prototype success and next generation upgrades

The Advanced X-ray Imaging Satellite (AXIS) is a NASA probe class mission concept designed to deliver arcsecond resolution with an effective area ten times that of Chandra (at launch). The AXIS focal plane features an MIT Lincoln Laboratory (MIT-LL) X-ray charge-coupled device (CCD) detector working in conjunction with an application specific integrated circuit (ASIC), denoted the Multi-Channel Readout Chip (MCRC). While this readout ASIC targets the AXIS mission, it is applicable to a range of potential X-ray missions with comparable readout requirements. Designed by the X-ray astronomy and Observational Cosmology (XOC) group at Stanford University, the MCRC ASIC prototype (MCRC-V1.0) uses a 350 nm technology node and provides 8 channels of high speed, low noise, low power consumption readout electronics. Each channel implements a current source to bias the detector output driver, a preamplifier to provide gain, and an output buffer to interface directly to an analog-to-digital (ADC) converter. The MCRC-V1 ASIC exhibits comparable performance to our best discrete electronics implementations, but with ten times less power consumption and a fraction of the footprint area. In a total ionizing dose (TID) test, the chip demonstrated a radiation hardness equal or greater to 25 krad, confirming the suitability of the process technology and layout techniques used in its design. The next iteration of the ASIC (MCRC-V2) will expand the channel count and extend the interfaces to external circuits, advancing its readiness as a readout-on-a-chip solution for next generation X-ray CCD-like detectors. This paper summarizes our most recent characterization efforts, including the TID radiation campaign and results from the first operation of the MCRC ASIC in combination with a representative MIT-LL CCD.

astro-ph.IM↗

The Advanced CCD Imaging Spectrometer on the Chandra X-ray Observatory: twenty-five years of on-orbit operation

As the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory completes a quarter century of on orbit operations, it continues to perform well and produce spectacular scientific results. The response of ACIS has evolved over the lifetime of the observatory due to radiation damage, molecular contamination, changing particle environment, and aging of the spacecraft in general. We present highlights from the instrument team's monitoring program and our expectations for the future of ACIS. Performance changes on ACIS continue to be manageable, and do not indicate any limitations on ACIS lifetime. We examine aspects of the design and operation of ACIS that have impacted its long lifetime with lessons learned for future instruments.

astro-ph.IM↗

Curved detectors for future X-ray astrophysics missions

Future X-ray astrophysics missions will survey large areas of the sky with unparalleled sensitivity, enabled by lightweight, high-resolution optics. These optics inherently produce curved focal surfaces with radii as small as 2 m, requiring a large area detector system that closely conforms to the curved focal surface. We have embarked on a project using a curved charge-coupled device (CCD) detector technology developed at MIT Lincoln Laboratory to provide large-format, curved detectors for such missions, improving performance and simplifying design. We present the current status of this work, which aims to curve back-illuminated, large-format (5 cm x 4 cm) CCDs to 2.5-m radius and confirm X-ray performance. We detail the design of fixtures and the curving process, and present intial results on curving bare silicon samples and monitor devices and characterizing the surface geometric accuracy. The tests meet our accuracy requirement of <5 $μ$m RMS surface non-conformance for samples of similar thickness to the functional detectors. We finally show X-ray performance measurements of planar CCDs that will serve as a baseline to evaluate the curved detectors. The detectors exhibit low noise, good charge-transfer efficiency, and excellent, uniform spectroscopic performance, including in the important soft X-ray band.

astro-ph.IM↗

Demonstrating repetitive non-destructive readout (RNDR) with SiSeRO devices

We demonstrate so-called repetitive non-destructive readout (RNDR) for the first time on a Single electron Sensitive Readout (SiSeRO) device. SiSeRO is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors, developed at MIT Lincoln Laboratory. This technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. RNDR was realized by transferring the signal charge non-destructively between the internal gate and the summing well (SW), which is the last serial register. The advantage of the non-destructive charge transfer is that the signal charge for each pixel can be measured at the end of each transfer cycle and by averaging for a large number of measurements ($\mathrm{N_{cycle}}$), the total noise can be reduced by a factor of 1/$\mathrm{\sqrt{N_{cycle}}}$. In our experiments with a prototype SiSeRO device, we implemented nine ($\mathrm{N_{cycle}}$ = 9) RNDR cycles, achieving around 2 electron readout noise (equivalent noise charge or ENC) with spectral resolution close to the fano limit for silicon at 5.9 keV. These first results are extremely encouraging, demonstrating successful implementation of the RNDR technique in SiSeROs. They also lay foundation for future experiments with more optimized test stands (better temperature control, larger number of RNDR cycles, RNDR-optimized SiSeRO devices) which should be capable of achieving sub-electron noise sensitivities. This new device class presents an exciting technology for next generation astronomical X-ray telescopes requiring very low-noise spectroscopic imagers. The sub-electron sensitivity also adds the capability to conduct in-situ absolute calibration, enabling unprecedented characterization of the low energy instrument response.

astro-ph.IM↗

ZWCL 1856.8 : A rare double radio relic system captured within NuSTAR and Chandra field of view

Observations of galaxy cluster mergers provide insights on the particle acceleration and heating mechanisms taking place within the intracluster medium. Mergers form shocks that propagate through the plasma, which result in shock/cold fronts in the X-ray, and radio halos and/or relics in the radio regime. The connection between these tracers and the mechanisms driving non-thermal processes, such as inverse Compton, are not well understood. ZWCL 1856.8 is one of the few known double radio relic systems that originate from nearly head-on collisions observed close to the plane of the sky. For the first time, we study NuSTAR and Chandra observations of such a system that contains both relics within their field of view. The spectro-imaging analyses results of the system suggest weak shock fronts with $\mathcal{M}$ numbers within 2$σ$ of the radio derived values, and provide evidence of inverse Compton emission at both relic sites. Our findings have great uncertainties due to the shallow exposure times available. Deeper NuSTAR and Chandra data are crucial for studying the connection of the radio and X-ray emission features and for constraining the thermal vs. non-thermal emission contributions in this system. We also present methods and approaches on how to investigate X-ray properties of double relic systems by taking full advantage of the complementary properties of NuSTAR and Chandra missions.

astro-ph.HE↗

Gas clumping in the outskirts of galaxy clusters, an assessment of the sensitivity of STAR-X

In the outskirts of galaxy clusters, entropy profiles measured from X-ray observations of the hot intracluster medium (ICM) drops off unexpectedly. One possible explanation for this effect is gas clumping, where pockets of cooler and denser structures within the ICM are present. Current observatories are unable to directly detect these hypothetical gas clumps. One of the science drivers of the proposed STAR-X observatory is to resolve these or similar structures. Its high spatial resolution, large effective area, and low instrumental background make STAR-X ideal for directly detecting and characterizing clumps and diffuse emission in cluster outskirts. The aim of this work is to simulate observations of clumping in clusters to determine how well STAR-X will be able to detect clumps, as well as what clumping properties reproduce observed entropy profiles. This is achieved by using yt, pyXSIM, SOXS, and other tools to inject ideally modeled clumps into three-dimensional models derived from actual clusters using their observed profiles from other X-ray missions. Radial temperature and surface brightness profiles are then extracted from mock observations using concentric annuli. We find that in simulated observations for STAR-X, a parameter space of clump properties exists where gas clumps can be successfully identified using wavdetect and masked, and are able to recover the true cluster profiles. This demonstrates that STAR-X could be capable of detecting substructure in the outskirts of nearby clusters and that the properties of both the outskirts and the clumps will be revealed.

astro-ph.IM↗

The high-speed X-ray camera on AXIS

AXIS is a Probe-class mission concept that will provide high-throughput, high-spatial-resolution X-ray spectral imaging, enabling transformative studies of high-energy astrophysical phenomena. To take advantage of the advanced optics and avoid photon pile-up, the AXIS focal plane requires detectors with readout rates at least 20 times faster than previous soft X-ray imaging spectrometers flying aboard missions such as Chandra and Suzaku, while retaining the low noise, excellent spectral performance, and low power requirements of those instruments. We present the design of the AXIS high-speed X-ray camera, which baselines large-format MIT Lincoln Laboratory CCDs employing low-noise pJFET output amplifiers and a single-layer polysilicon gate structure that allows fast, low-power clocking. These detectors are combined with an integrated high-speed, low-noise ASIC readout chip from Stanford University that provides better performance than conventional discrete solutions at a fraction of their power consumption and footprint. Our complementary front-end electronics concept employs state of the art digital video waveform capture and advanced signal processing to deliver low noise at high speed. We review the current performance of this technology, highlighting recent improvements on prototype devices that achieve excellent noise characteristics at the required readout rate. We present measurements of the CCD spectral response across the AXIS energy band, augmenting lab measurements with detector simulations that help us understand sources of charge loss and evaluate the quality of the CCD backside passivation technique. We show that our technology is on a path that will meet our requirements and enable AXIS to achieve world-class science.

astro-ph.IM↗

Improved noise performance from the next-generation buried-channel p-Mosfet SiSeROs

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge (ENC) of around 15 electrons root mean square (RMS) was obtained. In this work, we examine the first buried-channel SiSeRO. We have achieved substantially improved noise performance of around 4.5 electrons root mean square (RMS) and a full width half maximum (FWHM) energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel/s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting new technology for the next-generation astronomical X-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

astro-ph.IM↗

Understanding the effects of charge diffusion in next-generation soft X-ray imagers

To take advantage of high-resolution optics sensitive to a broad energy range, future X-ray imaging instruments will require thick detectors with small pixels. This pixel aspect ratio affects spectral response in the soft X-ray band, vital for many science goals, as charge produced by the photon interaction near the entrance window diffuses across multiple pixels by the time it is collected, and is potentially lost below the imposed noise threshold. In an effort to understand these subtle but significant effects and inform the design and requirements of future detectors, we present simulations of charge diffusion using a variety of detector characteristics and operational settings, assessing spectral response at a range of X-ray energies. We validate the simulations by comparing the performance to that of real CCD detectors tested in the lab and deployed in space, spanning a range of thickness, pixel size, and other characteristics. The simulations show that while larger pixels, higher bias voltage, and optimal backside passivation improve performance, reducing the readout noise has a dominant effect in all cases. We finally show how high-pixel-aspect-ratio devices present challenges for measuring the backside passivation performance due to the magnitude of other processes that degrade spectral response, and present a method for utilizing the simulations to qualitatively assess this performance. Since compelling science requirements often compete technically with each other (high spatial resolution, soft X-ray response, hard X-ray response), these results can be used to find the proper balance for a future high-spatial-resolution X-ray instrument.

astro-ph.IM↗

Single electron Sensitive Readout (SiSeRO) X-ray detectors: Technological progress and characterization

Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. Characterization was performed for a number of prototype sensors with different device architectures, e.g. location of the internal gate, MOSFET polysilicon gate structure, and location of the trough in the internal gate with respect to the source and drain of the MOSFET (the trough is introduced to confine the charge in the internal gate). Using a buried-channel SiSeRO, we have achieved a charge/current conversion gain of >700 pA per electron, an equivalent noise charge (ENC) of around 6 electrons root mean square (RMS), and a full width half maximum (FWHM) of approximately 140 eV at 5.9 keV at a readout speed of 625 Kpixel/s. In this paper, we discuss the SiSeRO working principle, the readout module developed at Stanford, and the characterization test results of the SiSeRO prototypes. We also discuss the potential to implement Repetitive Non-Destructive Readout (RNDR) with these devices and the preliminary results which can in principle yield sub-electron ENC performance. Additional measurements and detailed device simulations will be essential to mature the SiSeRO technology. However, this new device class presents an exciting technology for next generation astronomical X-ray telescopes requiring fast, low-noise, radiation hard megapixel imagers with moderate spectroscopic resolution.

astro-ph.IM↗

Towards precision particle background estimation for future X-ray missions: correlated variability between Chandra ACIS and AMS

A science goal of many future X-ray observatories is mapping the cosmic web through deep exposures of faint diffuse sources. Such observations require low background and the best possible knowledge of the remaining unrejected background. The dominant contribution to the background above 1-2 keV is from Galactic Cosmic Ray protons. Their flux and spectrum are modulated by the solar cycle but also by solar activity on shorter timescales. Understanding this variability may prove crucial to reducing background uncertainty for ESA's Athena X-ray Observatory and other missions with large collecting area. We examine of the variability of the particle background as measured by ACIS on the Chandra X-ray Observatory and compare that variability to that measured by the Alpha Magnetic Spectrometer (AMS), a precision particle detector on the ISS. We show that cosmic ray proton variability measured by AMS is well matched to the ACIS background and can be used to estimate proton energies responsible for the background. We discuss how this can inform future missions.

astro-ph.IM↗

Mitigating the effects of particle background on the Athena Wide-Field Imager

The Wide Field Imager (WFI) flying on Athena will usher in the next era of studying the hot and energetic Universe. WFI observations of faint, diffuse sources will be limited by uncertainty in the background produced by high-energy particles. These particles produce easily identified "cosmic-ray tracks" along with signals from secondary photons and electrons generated by particle interactions with the instrument. The signal from these secondaries is identical to the X-rays focused by the optics, and cannot be filtered without also eliminating these precious photons. As part of a larger effort to understand the WFI background, we here present results from a study of background-reduction techniques that exploit the spatial correlation between cosmic-ray particle tracks and secondary events. We use Geant4 simulations to generate a realistic particle background, sort this into simulated WFI frames, and process those frames in a similar way to the expected flight and ground software to produce a WFI observation containing only particle background. The technique under study, Self Anti-Coincidence or SAC, then selectively filters regions of the detector around particle tracks, turning the WFI into its own anti-coincidence detector. We show that SAC is effective at improving the systematic uncertainty for observations of faint, diffuse sources, but at the cost of statistical uncertainty due to a reduction in signal. If sufficient pixel pulse-height information is telemetered to the ground for each frame, then this technique can be applied selectively based on the science goals, providing flexibility without affecting the data quality for other science. The results presented here are relevant for any future silicon-based pixelated X-ray imaging detector, and could allow the WFI and similar instruments to probe to truly faint X-ray surface brightness.

astro-ph.IM↗

Measurement and simulation of charge diffusion in a small-pixel charge-coupled device

Future high-resolution imaging X-ray observatories may require detectors with both fine spatial resolution and high quantum efficiency at relatively high X-ray energies (>5keV). A silicon imaging detector meeting these requirements will have a ratio of detector thickness to pixel size of six or more, roughly twice that of legacy imaging sensors. This implies greater diffusion of X-ray charge packets. We investigate consequences for sensor performance, reporting charge diffusion measurements in a fully-depleted, 50um thick, back-illuminated CCD with 8um pixels. We are able to measure the size distributions of charge packets produced by 5.9 keV and 1.25 keV X-rays in this device. We find that individual charge packets exhibit a gaussian spatial distribution, and determine the frequency distribution of event widths for a range of internal electric field strength levels. We find a standard deviation for the largest charge packets, which occur near the entrance window, of 3.9um. We show that the shape of the event width distribution provides a clear indicator of full depletion and infer the relationship between event width and interaction depth. We compare measured width distributions to simulations. We compare traditional, 'sum-above-threshold' algorithms for event amplitude determination to 2D gaussian fitting of events and find better spectroscopic performance with the former for 5.9 keV events and comparable results at 1.25 keV. The reasons for this difference are discussed. We point out the importance of read noise driven detection thresholds in spectral resolution, and note that the derived read noise requirements for mission concepts such as AXIS and Lynx may be too lax to meet spectral resolution requirements. While we report measurements made with a CCD, we note that they have implications for the performance of high aspect-ratio silicon active pixel sensors as well.

astro-ph.IM↗

Reducing the Athena WFI charged particle background: Results from Geant4 simulations

One of the science goals of the Wide Field Imager (WFI) on ESA's Athena X-ray observatory is to map hot gas structures in the universe, such as clusters and groups of galaxies and the intergalactic medium. These deep observations of faint diffuse sources require low background and the best possible knowledge of that background. The WFI Background Working Group is approaching this problem from a variety of directions. Here we present analysis of Geant4 simulations of cosmic ray particles interacting with the structures aboard Athena, producing signal in the WFI. We search for phenomenological correlations between these particle tracks and detected events that would otherwise be categorized as X-rays, and explore ways to exploit these correlations to flag or reject such events in ground processing. In addition to reducing the Athena WFI instrumental background, these results are applicable to understanding the particle component in any silicon-based X-ray detector in space.

astro-ph.IM↗

Overview of the High-Definition X-ray Imager instrument on the Lynx x-ray surveyor

Four NASA Science and Technology Definition Teams have been convened in order to develop and study four mission concepts to be evaluated by the upcoming 2020 Decadal Survey. The Lynx x-ray surveyor mission is one of these four large missions. Lynx will couple fine angular resolution (<0.5 arcsec HPD) x-ray optics with large effective area (~2 m^2 at 1 keV), thus enabling exploration within a unique scientific parameter space. One of the primary soft x-ray imaging instruments being baselined for this mission concept is the high-definition x-ray imager, HDXI. This instrument would use a finely pixelated silicon sensor array to achieve fine angular resolution imaging over a wide field of view (~22 x 22 arcmin). Silicon sensors enable large-format/small-pixel devices, radiation tolerant designs, and high quantum efficiency across the entire soft x-ray bandpass. To fully exploit the large collecting area of Lynx (~30x Chandra), with negligible or minimal x-ray event pile-up, the HDXI will be capable of much faster frame rates than current x-ray imagers. We summarize the planned requirements, capabilities, and development status of the HDXI instrument, and associated papers in this special edition will provide further details on some specific detector options.

astro-ph.IM↗

Detection of polarized gamma-ray emission from the Crab nebula with Hitomi Soft Gamma-ray Detector

We present the results from the Hitomi Soft Gamma-ray Detector (SGD) observation of the Crab nebula. The main part of SGD is a Compton camera, which in addition to being a spectrometer, is capable of measuring polarization of gamma-ray photons. The Crab nebula is one of the brightest X-ray / gamma-ray sources on the sky, and, the only source from which polarized X-ray photons have been detected. SGD observed the Crab nebula during the initial test observation phase of Hitomi. We performed the data analysis of the SGD observation, the SGD background estimation and the SGD Monte Carlo simulations, and, successfully detected polarized gamma-ray emission from the Crab nebula with only about 5 ks exposure time. The obtained polarization fraction of the phase-integrated Crab emission (sum of pulsar and nebula emissions) is (22.1 $\pm$ 10.6)% and, the polarization angle is 110.7$^o$ + 13.2 / $-$13.0$^o$ in the energy range of 60--160 keV (The errors correspond to the 1 sigma deviation). The confidence level of the polarization detection was 99.3%. The polarization angle measured by SGD is about one sigma deviation with the projected spin axis of the pulsar, 124.0$^o$ $\pm$0.1$^o$.

astro-ph.HE↗