WULPUS PRO: Multi-mode Ultra-Low-Power Wearable Ultrasound and Array Imaging with CMUT Support

Wearable ultrasound enables continuous monitoring of physiological processes such as muscle dynamics, bladder volume, and cardiovascular activity. Existing fully wearable ultra-low-power platforms are limited to shallow, low-channel A-mode sensing, while larger multi-mode systems are too bulky and power-hungry for true wearability. We present WULPUS PRO, a runtime-programmable wearable ultrasound acquisition platform measuring $39\times21\times6 \mathrm{mm}$ and weighing $5 \mathrm{g}$. It integrates $30 \mathrm{V}$ excitation, 16 time-multiplexed channels, a low-noise receive front-end with up to $70 \mathrm{dB}$ gain, $9.9 \mathrm{MHz}$ bandwidth, time-gain compensation, and $32 \mathrm{dB}$ SNR. The platform supports deep-tissue echo acquisition up to $2.2 \mathrm{MHz}$ in RF-sampling mode and $8 \mathrm{MHz}$ in envelope-detection mode. We demonstrate B-mode imaging in a 16-channel ultra-low-power wearable with sub-millimeter axial and millimeter-scale lateral resolution in phantom experiments, while consuming $40 \mathrm{mW}$ at $50 \mathrm{Hz}$ PRF and under $60 \mathrm{mW}$ at $300 \mathrm{Hz}$ PRF. WULPUS PRO supports both piezoelectric and capacitive micromachined ultrasonic transducers, enabling integration with skin-conformal polymer-based CMUT arrays. As a host-agnostic acquisition front-end, it exposes standard data and power interfaces for BLE- and Wi-Fi-based wearable hosts. We demonstrate wireless transmission with external BLE and Wi-Fi modules and project 1-2 days of BLE operation at $50 \mathrm{Hz}$ PRF and over 3 h of Wi-Fi streaming at $300 \mathrm{Hz}$ PRF using a $300 \mathrm{mAh}$, $6.4 \mathrm{g}$ Li-Po cell. WULPUS PRO establishes a new class of fully programmable, B-mode-enabled, ultra-low-power wearable ultrasound platforms.

eess.SY

Polymer-based Capacitive Micromachined Transducer-Enabled Inline Monitoring of Ultrasonic Welding in Thermoplastic Carbon Fiber Composites

Thermoplastic composite structures enable lightweight, recyclable, and high-throughput aerospace manufacturing, but reliable quality assurance of advanced joining processes remains a key challenge. This work presents a compact, low-cost, and wireless ultrasonic non-destructive testing system for real-time, inline monitoring of continuous ultrasonic welding of thermoplastic carbon fiber composites. The system integrates custom-fabricated polymer-based capacitive micromachined ultrasonic transducers (polyCMUTs) with the ultra-low-power WULPUS platform, enabling operation in the harsh, high-interference welding environment. An eight-element linear polyCMUT array operating at a center frequency of approximately 3.6 MHz is designed, fabricated, packaged, and integrated into an industrial welding setup. Inline measurements are performed during welding of carbon fiber laminates with intentionally introduced defects. Process-synchronous ultrasonic data reveal consistent depth-of-echo shifts at defect locations, in strong agreement with X-ray computed tomography ground truth. Across 21 welds, all induced defects are detected without false negatives and with limited false positives. The results demonstrate that polymer-based CMUT technology enables robust, scalable, and manufacturing-compatible ultrasonic sensing, representing a decisive step toward intelligent process monitoring and quality assurance for next-generation thermoplastic composite welding.

eess.SY