Martin F. Schiffner

Publications and source records attributed to Martin F. Schiffner.

4 recordsLinked to original sources

Frequency-Dependent F-Numbers Suppress Grating Lobes and Improve the Lateral Resolution in Line-by-Line Scanning

Line-by-line scanning with linear arrays is a standard image formation method in clinical ultrasound. This method examines progressively a given region of interest by conducting focused pulse-echo measurements with dynamic transmit and receive apertures. Such apertures widen with the focal length as a function of a given F-number and improve the image quality by extending the depth of field (DOF) and suppressing grating lobes. Fixed F-numbers, however, limit the lateral resolution. Herein, frequency dependence of the F-number is incorporated into both the transmit and the receive focusing to widen the apertures for low frequencies and improve the lateral resolution. Frequency-dependent transmit and receive F-numbers are proposed. These F-numbers, which can be expressed in closed form, maximize the lateral resolution under constraints on the DOF and the grating lobes. A phantom experiment showed that the proposed F-numbers eliminate grating lobe artifacts and improve both image uniformity and contrast to a similar extent as fixed F-numbers. These metrics, compared to the usage of the full apertures, improved by up to 14.1 % and 8.3 %, respectively. The proposed F-numbers, however, improved the lateral resolution by up to 24 % compared to the fixed F-numbers.

physics.med-ph

Frequency-Dependent F-Number Increases the Contrast and the Spatial Resolution in Fast Pulse-Echo Ultrasound Imaging

Fixed $F$-numbers reduce grating lobe artifacts in fast pulse-echo ultrasound imaging. Such $F$-numbers result in dynamic receive subapertures whose widths vary with the focal position. These subapertures, however, ignore useful low-frequency components in the excluded radio frequency (RF) signals and, thus, reduce the lateral resolution. Here, we propose a frequency-dependent $F$-number to simultaneously suppress grating lobe artifacts and maintain the lateral resolution. This $F$-number, at high frequencies, reduces the receive subaperture to remove spatially undersampled components of the RF signals and suppress grating lobes. The $F$-number, at low frequencies, enlarges the receive subaperture to use the components of all RF signals and maintain the lateral resolution. Experiments validated the proposed $F$-number and demonstrated improvements in the contrast and the widths of wire targets of up to 3.2 % and 12.8 %, respectively.

physics.med-ph

Rhombic Grids Reduce the Number of Voxels in Fast Pulse-Echo Ultrasound Imaging

Ultrafast imaging modes, such as coherent plane-wave compounding (CPWC), capture a large field of view in a single pulse-echo measurement using parallel receive focusing. The number of foci or, equivalently, the number of volume elements (voxels) in the image determines the computational costs and the memory consumption of the image formation. Herein, 120° rhombic grids are proposed to specify the voxel positions and reduce the number of voxels in comparison to orthogonal grids. The proposed grids derive from the bivariate sampling theorem and the spectral properties of the images formed by the delay-and-sum algorithm in CPWC. A phantom experiment validated the proposed grids and showed reductions in the number of voxels by 81.4 % and 14.7 % in comparison to the usual and optimal orthogonal grids, respectively. Mean structural similarity indices above 96.6 % and relative root mean-squared errors below 6.8 % confirmed the visual equivalence of all images after interpolations to the usual orthogonal grid.

physics.med-ph

Random Incident Waves for Fast Compressed Pulse-Echo Ultrasound Imaging

Established image recovery methods in fast ultrasound imaging, e.g. delay-and-sum, trade the image quality for the high frame rate. Cutting-edge inverse scattering methods based on compressed sensing (CS) disrupt this tradeoff via a priori information. They iteratively recover a high-quality image from only a few sequential pulse-echo measurements or less echo signals, if (i) a known dictionary of structural building blocks represents the image almost sparsely, and (ii) their individual pulse echoes, which are predicted by a linear model, are sufficiently uncorrelated. The exclusive modeling of the incident waves as steered plane waves or cylindrical waves, however, has so far limited the convergence speed, the image quality, and the potential to meet condition (ii). Motivated by the benefits of randomness in CS, a novel method for the fast compressed acquisition and the subsequent recovery of images is proposed to overcome these limitations. It recovers the spatial compressibility fluctuations in weakly-scattering soft tissue structures, where an orthonormal basis meets condition (i), by a sparsity-promoting $\ell_{q}$-minimization method, $q \in [0; 1]$. A realistic $d$-dimensional model, $d \in \{2, 3\}$, accounting for diffraction, single monopole scattering, the combination of power-law absorption and dispersion, and the specifications of a planar transducer array, predicts the pulse echoes of the individual basis functions. Three innovative types of incident waves, whose syntheses leverage random apodization weights, time delays, or combinations thereof, aid in meeting condition (ii). In two-dimensional numerical simulations, single realizations of these waves outperform the prevalent quasi-plane wave for both the canonical and the Fourier bases. They significantly reduce the full extents at half maximum of the point spread functions by up to 73.7 %.

physics.med-ph