Improvements of the programmable quantum current generator for better traceability of electrical current measurements

A programmable quantum current generator based on the application of Ohm's law to quantum voltage and resistance standards has demonstrated a realization of the ampere from the elementary charge with a $10^{-8}$ relative uncertainty [J. Brun-Picard et al. PRX 6, 041051, 2016]. Here, we report on improvements of the device leading to a noise reduction of the generated quantized current. The improved quantum current generator is used to calibrate different ammeters with lower measurement uncertainties. Besides, measurements of its quantized current using a calibrated Ultrastable Low-Noise Current Amplifier (ULCA) have shown that the realizations of the ampere at PTB (Physikalisch-Technische Bundesanstalt) and LNE (Laboratoire national de métrologie et d'essais) in the range $\pm50$ $μ$A agreed to -3.7 parts in $10^{7}$ with a combined standard uncertainty of 3.1 parts in $10^{7}$ (coverage factor $k_\mathrm{c}=1$).

physics.ins-det

Electrometer calibration with sub-part-per-million uncertainty

We performed calibrations of four different commercial picoammeters using the Ultrastable Low-noise Current Amplifier (ULCA) as a calibrator current source operated in the range between 1 femtoampere and 1 microampere. The results allow the comprehensive characterization of the devices under test regarding noise, settling and burden voltage behavior as well as stability of the gain factor, and confirm the performance of the ULCA for use as small-current calibrator standard. Also, we present a further advanced setup for the calibration of transimpedance amplifiers. Accuracy limits for best electrometer calibrations in the current range between 1 femtoampere and 1 microampere and possible implications on corresponding calibration and measurement capabilities are discussed.

physics.ins-det

Direct Comparison of Fractional and Integer Quantized Hall Resistance

We present precision measurements of the fractional quantized Hall effect where the quantized resistance $R^{[1/3]}$ in the fractional quantum Hall state at filling factor 1/3 was compared with a quantized resistance $R^{[2]}$, represented by an integer quantum Hall state at filling factor 2. A cryogenic current comparator bridge capable of currents down to the nanoampere range was used to directly compare two resistance values of two GaAs-based devices located in two cryostats. A value of $1 - (5.3 \pm 6.3) 10^{-8}$ (95% confidence level) was obtained for the ratio $(R^{[1/3]}/6R^{[2]})$. This constitutes the most precise comparison of integer resistance quantization (in terms of $h/e^2$) in single-particle systems and of fractional quantization in fractionally charged quasi-particle systems. While not relevant for practical metrology, such a test of the validity of the underlying physics is of significance in the context of the up-coming revision of the SI.

cond-mat.mes-hall

Validation of the ultrastable low-noise current amplifier as travelling standard for small direct currents

An interlaboratory comparison of small-current generation and measurement capability is presented with the ultrastable low-noise current amplifier (ULCA) acting as travelling standard. Various measurements at direct currents between 0.16 nA and 13 nA were performed to verify the degree of agreement between the three national metrology institutes involved in the study. Consistency well within one part per million (ppm) was found. Due to harsh environmental conditions during shipment, the ULCA's transfer accuracy had been limited to about +/-0.4 ppm. Supplemental measurements performed at PTB indicate that further improvements in accuracy are possible. Relative uncertainties of 0.1 ppm are achieved by applying on-site calibration of the ULCA with a suitable cryogenic current comparator.

physics.ins-det

Validation of a quantized-current source with 0.2 ppm uncertainty

We report on high-accuracy measurements of quantized current, sourced by a tunable-barrier single-electron pump at frequencies $f$ up to $1$ GHz. The measurements were performed with a new picoammeter instrument, traceable to the Josephson and quantum Hall effects. Current quantization according to $I=ef$ with $e$ the elementary charge was confirmed at $f=545$ MHz with a total relative uncertainty of 0.2 ppm, improving the state of the art by about a factor of 5. For the first time, the accuracy of a possible future quantum current standard based on single-electron transport was experimentally validated to be better than the best realization of the ampere within the present SI.

cond-mat.mes-hall

Traceable precision pA direct current measurements with the ULCA

A standard method for picoammeter calibrations is the capacitor charging technique, which allows generating traceable currents in the sub-nA range. However, its accuracy is limited by the ac-dc differences of the capacitances involved. The Ultrastable Low-noise Current Amplifier (ULCA) is a novel high-precision amperemeter for direct current measurements in the pA range, developed at PTB. Its amplifier stages, based on resistor networks and op-amps, can be calibrated traceably with a cryogenic current comparator (CCC) system. We compare the results from both independent calibration routes for two different ULCA prototypes. We find agreement between both methods at an uncertainty level below 10 microA/A, limited by the uncertainty of the currents generated with the capacitor charging method. The investigations confirm the superior performance of the new ULCA picoammeter.

physics.ins-det

Traceable precision generation and measurement of pA direct currents

We present the comparison of results from the generation and the measurement of direct currents in the pA range, performed with traceable state-of-the-art methods at highest accuracy. The currents were generated with the capacitor charging method, and measured with the first prototype of a novel picoammeter developed at PTB. The results confirm the agreement between both methods and the linearity of the new picoammeter at an uncertainty level of few microA/A. Also, they shed light on the ac-dc difference of capacitors, crucial for current generation with the capacitor charging method.

cond-mat.other

Precision quantization of Hall resistance in transferred graphene

We show that quantum resistance standards made of transferred graphene reach the uncertainty of semiconductor devices, the current reference system in metrology. A large graphene device (150 \times 30 \mum2), exfoliated and transferred onto GaAs, revealed a quantization with a precision of (-5.1 \pm 6.3) \times 10-9 accompanied by a vanishing longitudinal resistance at current levels exceeding 10 \muA. While such performance had previously only been achieved with epitaxially grown graphene, our experiments demonstrate that transfer steps, inevitable for exfoliated graphene or graphene grown by chemical vapor deposition (CVD), are compatible with the requirements of high quality quantum resistance standards.

cond-mat.mes-hall

Ground-state characterization of Nb charge-phase Josephson qubits

We present investigations of Josephson charge-phase qubits inductively coupled to a radio-frequency driven tank-circuit enabling the readout of the states by measuring the Josephson inductance of the qubit. The circuits including junctions with linear dimensions of 60 nm and 80 nm are fabricated from Nb trilayer and allowing the determination of relevant sample parameters at liquid helium temperature. The observed partial suppression of the circulating supercurrent at 4.2 K is explained in the framework of a quantum statistical model. We have probed the ground-state properties of qubit structures with different ratios of the Josephson coupling to Coulomb charging energy at 20 mK, demonstrating both the magnetic control of phase and the electrostatic control of charge on the qubit island.

cond-mat.mes-hall