SearcharxivSearch

arXiv subjects

Martine Pithioux

Publications and source records attributed to Martine Pithioux.

7 recordsLinked to original sources

Structural gradients and strain partitioning across the mouse Achilles tendon enthesis revealed by in situ X-ray scattering

The enthesis is the insertion site of tendon into bone and exhibits a high mechanical durability despite the large mismatch in material properties between the two tissues. This durability stems from gradients in composition, structure and organization on multiple hierarchical length scales. Despite extensive research on enthesis structure and mechanics, the local deformation mechanisms are poorly understood. Synchrotron scanning small- and wide-angle X-ray scattering was combined with in situ tensile testing of the mouse Achilles tendon enthesis to extensively map the mechanical response of the collagen fibrils and molecules as well as the hydroxyapatite mineral particles and crystals. Gradients in nano- and molecular scale structure and a stronger and more immediate deformation response towards the interface compared to further away were observed in both the soft and mineralized tissue. The strain decreased progressively across hierarchical levels; with an applied tissue strain of 20% the nanoscale fibrils were strained by ~1-2%, the collagen molecules by ~0.5% and the hydroxyapatite crystals by ~0.05%, thus following an approximate ratio of 1 : 0.1 : 0.01 : 0.001. These results show that load transfer across the enthesis is both spatially heterogeneous and hierarchy-dependent. This indicates that the graded attachment accommodates deformation through region-specific load sharing and hierarchical strain partitioning, consistent with a contribution from dissipation within the non-collagenous matrix. In doing so, the enthesis can mitigate stress concentrations and maintain mechanical integrity across the tendon-to-bone transition.

physics.bio-ph

Femoral fracture load and damage localisation pattern prediction based on a quasi-brittle law : linear and non-linear FE meshing

Finite element analysis is one of the most used tool for studying femoral neck fracture. Nerveless, consensus concerning either the choice of material characteristics, damage law and /or geometric models (linear on nonlinear) still remains unreached. In this work, we propose a numerical quasi-brittle damage model to describe the behavior of the proximal femur associated with two methods to evaluate the Young modulus. 8 proximal femur finite elements models were constructed from CT scan data (4 donors, 3 men; 1 woman). The results obtained from the numerical computations showed a good agreement between the numerical curves (load-displacement) and the experimental ones. The computed fracture loads were very close to the experimental ones (R 2 =0.825, Relative error =6.49%). The damage patterns were similar to those observed during the failure during sideway fall experimental simulation. Finally, a comparative study based on 32 simulations, using a linear and nonlinear mesh has led to the conclusion that the results are improved when a nonlinear mesh is used. In summary, the numerical quasi-brittle model presented in this work showed its efficiency to find the experimental values during the simulation of the side fall.

physics.med-ph

Temporal evolution of mechanical properties of skeletal tissue regeneration in rabbits. An experimental study

Various mathematical models represent the effects of local mechanical environment on the regulation of skeletal regeneration. Their relevance relies on an accurate description of the evolving mechanical properties of the regenerating tissue. The object of this study was to develop an experimental model which made it possible to characterize the temporal evolution of the structural and mechanical properties during unloaded enchondral osteogenesis in the New Zealand rabbit, a standard animal model for studies of osteogenesis and chondrogenesis. A 25mm segment of tibial diaphysis was removed sub-periosteally from rabbits. The defect was repaired by the preserved periosteum. An external fixator was applied to prevent mechanical loading during osteogenesis. The regenerated skeletal tissues were studied by CT scan, histology and mechanical tests. The traction tests between 7 to 21 days post-surgery were done on formaldehyde-fixated tissue allowing to obtain force/displacement curves. The viscoelastic properties of the regenerating skeletal tissues were visualized throughout the repair process.

physics.med-ph

Influence of muscle preactivation of the lower limb on impact dynamics in case of frontal collision

Accidentology or shock biomechanics are research domains mainly devoted to the development of safety conditions for the users of various transport modes in case of an accident. The objective of this study was to improve the knowledge of the biomechanical behaviour of the lower limb facing sudden dynamic loading during a frontal collision. We aimed at establishing the relationship between the level of muscular activity prior to impact, called 'preactivation', of the lower limb extensors and the mechanical characteristics of impact. Relationships were described between the level of preactivation, the impact peak force values, the minimum force after unloading and the associated loading and unloading rates. The existence of reflex mechanisms that were affected by the level of voluntary muscular preactivation for the lower limb muscles was demonstrated. In conclusion, the existence of specific mechanism acting mainly at the knee level may result from the level of preactivation. Muscle behavior has to be included in numerical models of the human driver to better evaluate the overall stiffness of the body before and at impact.

physics.class-ph

An alternative ultrasonic method for measuring the elastic properties of cortical bone

We studied the elastic properties of bone to analyze its mechanical behavior. The basic principles of ultrasonic methods are now well established for varying isotropic media, particularly in the field of biomedical engineering. However, little progress has been made in its application to anisotropic materials. This is largely due to the complex nature of wave propagation in these media. In the present study, the theory of elastic waves is essential because it relates the elastic moduli of a material to the velocity of propagation of these waves along arbitrary directions in a solid. Transducers are generally placed in contact with the samples which are often cubes with parallel faces that are difficult to prepare. The ultrasonic method used here is original, a rough preparation of the bone is sufficient and the sample is in rotation. Moreover, to analyze heterogeneity of the structure we measure velocities in different points on the sample. The aim of the present study was to determine in vitro the anisotropic elastic properties of cortical bones. For this purpose, our method allowed measuring longitudinal and transversal velocities (CL and CT) in longitudinal (fiber direction) and radial directions (orthogonal to the fiber direction) of compact bones. Young's modulus E and Poisson's ratio , were then deduced from the velocities measured considering the compact bone as transversely isotropic or orthotropic. The results are in line with those of other methods.

physics.class-ph

Comparison of compact bone failure under two different loadings rates: experimental and modelling approaches

Understanding the mechanical behaviour of bones up to failure is necesary for diagnosis and prevention of accident and trauma. As far as we know, no authors have yet studied the tensile behaviour of compact bone including failure under dynamic loadings (1m/s). The originality of this study comes from not only the analysis of compact bone failure under dynamic loadings, the results of which are compared to those obtained under quasi static loadings but also the development of a statistical model. We developed a protocol using three different devices. Firstly, an X-ray scanner to analyse bone density, secondly, a common tensile device to perform quasi static experiments and thirdly, a special device based upon a hydraulic cylinder to perform dynamic tests. For all the tests, we used the same sample shape which took into account the brittleness of the compact bone. We first performed relaxation and hysteresis tests followed by tensile tests up to failure. Viscous and plastic effects were not relevant to the compact bone behaviour so its behaviour was considered elastic and brittle. The bovine compact bone was three to four times more brittle under a dynamic load than under a quasi static one. Numerically, a statistical model, based upon the Weibull theory is used to predict the failure stress in compact bone.

physics.class-ph

Constitutive Laws and Failure Models for Compact Bones Subjected to Dynamic Loading

Many biological tissues, such as bones and ligaments, are fibrous. The geometrical structure of these tissues shows that they exhibit a similar hierarchy in their ultra-structure and macro-structure. The aim of this work is to develop a model to study the failure of fibrous structures subjected to dynamic loading. The important feature of this model is that it describes failure in terms of the loss of cohesion between fibres. We have developed a model based on the lamellar structure of compact bone with fibres oriented at 0 degrees, 45 degrees and 90 degrees to the longitudinal axis of the bone, and have studied the influence of the model parameters on the failure process. Bone porosity and joint stress force at failure were found to be the most significant parameters. Using least square resolution, we deduced a phenomenological model of the lamellar structure. Finally, experimental results were found to be comparable with our numerical model.

physics.class-ph