High-resolution ultra-low-field MRI with SNRAware denoising

Ultra-low-field (ULF, <0.1 T) magnetic resonance imaging (MRI) systems offer advantages in cost, portability, and accessibility, but their current utility is still limited by low signal-to-noise ratio (SNR). Deep learning (DL)-based denoising has emerged as a potential strategy to mitigate this limitation. In this work, we present a systematic evaluation of a high-performance DL denoising model trained using the SNRAware framework and applied to 88 mT and 72 mT data. Using a series of controlled experiments, we assessed model performance as a function of spatial resolution, coil impedance matching, readout bandwidth, input noise level, k-space undersampling, anatomy, image contrast, and scanner platform, and compared against analytical denoising algorithms. The model consistently increased the effective SNR of ULF acquisitions, enabling images with nominal spatial resolutions comparable to those commonly used in clinical 3 T protocols. Residual analyses indicated that the model predominantly removed stochastic noise while preserving underlying signal structure. At the same time, the results highlight some constraints: denoising performance remains dependent on the starting SNR of the acquisition, and training-domain mismatch influences behavior under certain artifact conditions. These findings suggest that DL-based denoising can significantly expand the practical capabilities of ULF MRI, while emphasizing potential benefits from hardware-software co-optimization and the need for rigorous clinical validation to determine the diagnostic value of denoised images.

physics.med-ph↗

In-vivo imaging with a low-cost MRI scanner and cloud data processing in low-resource settings

Purpose: To demonstrate in-vivo imaging with a low-cost, low-field MRI scanner built and operated in Africa, and to show how systematic hardware and software improvements can mitigate the main operational limitations encountered in low-resource environments. Methods: A 46 mT Halbach scanner located at the Mbarara University of Science and Technology (Uganda) was upgraded through a complete reorganization of grounding and shielding, installation of new control electronics and open-source user-interface software. Noise performance was quantified using a standardized protocol and in-vivo brain images were acquired with three-dimensional RARE sequences. Distortion correction was implemented using cloud-based reconstructions incorporating magnetic field maps. Results: The revamped system reached noise levels routinely below three times the thermal limit and demonstrated stable operation over multi-day measurements. Three-dimensional T1- and T2-weighted brain images were successfully acquired and distortion-corrected with remote GPU-based reconstructions and near real-time visualization through the user interface. Conclusions: The results show that low-cost MRI systems can achieve clinically relevant image quality when electromagnetic noise and power-grid instabilities are properly addressed. This work highlights the feasibility of sustainable MRI development in low-resource settings and identifies stable power delivery and local capacity building as the key next steps toward clinical translation.

physics.med-ph↗