SearcharxivSearch

arXiv subjects

Masaaki Kitaguchi

Publications and source records attributed to Masaaki Kitaguchi.

At least 19 recordsLinked to original sources

Development and Characterization of Low-Scattering Vanadium Nanoparticle Targets for Short-Range Interaction Searches

We developed high-purity vanadium-based nanoparticle targets for neutron scattering experiments aimed at exploring gravity-like short-range new interactions in the submicron regime. Vanadium and V-Ni nanoparticles were fabricated using top-down and bottom-up methods and quantitatively characterized by SEM-EDS, ICP-AES, NDIR and SAXS. Through the performance tests, an RF thermal plasma method was found to be the best from viewpoints of the reproducibility, dispersion of the radius, and contamination of metallic elements. The oxygen incorporation during fabrication was quantified, and its impact on the effective coherent scattering length was evaluated, leading to a minimum average coherent scattering length of $\mathrm{0.719(23)\,fm}$, comparable to that of natural vanadium. These results demonstrate that vanadium-based nanoparticle targets with controlled composition and nanostructure can be systematically designed and fabricated to suppress nuclear scattering backgrounds, thereby enabling experimentally viable coherent neutron scattering measurements for short-range interaction searches.

physics.ins-det

First Constraint on P-odd/T-odd Cross Section in Polarized Neutron Transmission through Transversely Polarized $^{139}$La

We report the first constraint on time-reversal invariance violating (TRIV) effects in polarized neutron transmission through a transversely polarized $^{139}$La target. We formulate the transmission asymmetry within the density matrix formalism, explicitly incorporating the forward scattering amplitude of $^{139}$La including tensor polarization terms up to third-rank. The formalism is applied to existing transmission data originally obtained to measure the spin-dependent cross section near the $0.75$~eV $p$-wave resonance. Since these data were not optimized for P-odd/T-odd observables, the attainable sensitivity is intrinsically limited; nevertheless, they provide a useful test of the formalism on real experimental data. No statistically significant TRIV signal is observed. By analyzing the global $\chi^2$ structure in the parameter space, we obtain an upper limit of $|W_T|<15~\mathrm{eV}$ at the 90\% confidence level. This corresponds to an upper limit on the resonance-averaged TRIV cross section of $|\Delta\sigma_{\not{T}\not{P}}|<8.3\times10^2~\mathrm{b}$. These results validate the present theoretical framework and provide guidance for future dedicated TRIV searches in polarized neutron transmission experiments.

nucl-ex

Velocity dependence of the mass modifications of $\rho$ and $\omega$ mesons in 12 GeV $p+A$ reactions

This study measured the invariant mass spectra of $\rho$ and $\omega$ mesons in the $e^+e^-$ decay channel for 12 GeV (12.9 GeV/$c$) $p+\mathrm{C}$ and $p+\mathrm{Cu}$ reactions ($\sqrt{s}_{NN}=5.1$ GeV) at the KEK 12-GeV Proton Synchrotron. The measured spectra were divided into three $\beta\gamma$ regions to examine their velocity dependence. Across all regions, significant excesses were observed on the low-mass side of the $\omega$ meson peak, beyond the contributions of known hadronic sources, in the data of the C and Cu targets. Model calculations were subsequently performed to evaluate the magnitudes of the mass modifications of $\rho$ and $\omega$ mesons.

nucl-ex

Analysis of spectral modification of $\phi$ mesons at finite density using a transport approach in the 12 GeV pA reactions

The hadron spectrum at finite density is an important observable for exploring the origin of hadron masses. In the KEK-PS E325 experiment, the di-electron decays of phi mesons inside and outside nuclei were measured using 12 GeV pA reactions. In the previous analysis, a significant excess was observed on the low-mass side of the phi meson peak in the data for slow-moving phi mesons ($\beta\gamma=p_{\phi}/m_{\phi}<1.25$) with the Cu target, and in-medium vector meson spectral modification was verified. We newly employed the PHSD transport approach to take into account the time evolution of spatial density distribution of the target nuclei. Consistent with the previous analysis, a significant excess was observed in the present analysis as well. It was found that incorporating momentum dependence into the spectral modification leads to better agreement with the experimental results. For the slow-moving $\phi$ mesons with the Cu target, the newly obtained modification parameters are consistent with those from the previous analysis within the uncertainties.

nucl-ex

Proof-of-Principle Experiment on a Displacement-Noise-Free Neutron Interferometer for Gravitational Wave Detection

The displacement-noise-free interferometer (DFI) is designed to eliminate all displacement-induced noise while retaining sensitivity to gravitational wave (GW) signals. Ground-based DFIs suffer from physical arm-length limitations, resulting in poor sensitivity at frequencies below 1 kHz. To address this, previous research introduced a neutron-based DFI, which replaces laser light with neutrons and achieves exceptional sensitivity down to a few hertz. In this study, we conducted a proof-of-principle experiment using a pulsed neutron source at the Japan Proton Accelerator Research Complex (J- PARC). Despite practical constraints that led to deviations from the ideal experimental design, we optimized the setup and developed a novel analysis method that successfully cancels displacement noise while preserving simulated GW signals. This work presents the first successful demonstration of a neutron DFI and a neutron interferometer for GW detection.

physics.ins-det

Precision measurements of muonium and muonic helium hyperfine structure at J-PARC

At the J-PARC Muon Science Facility (MUSE), the MuSEUM collaboration is now performing new precision measurements of the ground state hyperfine structure (HFS) of both muonium and muonic helium atoms. High-precision measurements of the muonium ground-state HFS are recognized as one of the most sensitive tools for testing bound-state quantum electrodynamics theory to precisely probe the standard model and determine fundamental constants of the positive muon magnetic moment and mass. The same technique can also be employed to measure muonic helium HFS, obtain the negative muon magnetic moment and mass, and test and improve the theory of the three-body atomic system. Measurements at zero magnetic field have already yielded more accurate results than previous experiments for both muonium and muonic helium atoms. High-field measurements are now ready to start collecting data using the world's most intense pulsed muon beam at the MUSE H-line. We aim to improve the precision of previous measurements ten times for muonium and a hundred times or more for muonic helium. We review all the key developments for these new measurements, focusing on the high-field experiment, and report the latest results and prospects.

physics.atom-ph

Polarized cold-neutron reflectometry at JRR-3/MINE2 for the development of ultracold-neutron spin analyzers for a neutron EDM experiment at TRIUMF

The neutron electric dipole moment (EDM) is a sensitive probe for currently undiscovered sources of charge-parity symmetry violation. As part of the TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration, we are developing spin analyzers for ultracold neutrons (UCNs) to be used for a next-generation experiment to measure the neutron EDM with unprecedented precision. Spin-state analysis of UCNs constitutes an essential part of the neutron EDM measurement sequence. Magnetized iron films used as spin filters of UCNs are crucial experimental components, whose performance directly influences the statistical sensitivity of the measurement. To test such iron film spin filters, we propose the use of polarized cold-neutron reflectometry, in addition to conventional UCN transmission experiments. The new method provides information on iron film samples complementary to the UCN tests and accelerates the development cycles. We developed a collaborative effort to produce iron film spin filters and test them with cold and ultracold neutrons available at JRR-3/MINE2 and J-PARC/MLF BL05. In this article, we review the methods of neutron EDM measurements, discuss the complementarity of this new approach to test UCN spin filters, provide an overview of our related activities, and present the first results of polarized cold-neutron reflectometry recently conducted at the MINE2 beamline.

physics.ins-det

Demonstration of Near-Epithermal Neutron Reflective Optics

Specular reflection of neutrons on material surfaces has been demonstrated in the energy range of 0.09-0.7 eV. The results suggest that the applicable energy range of reflective neutron optics can be extended to the near-epithermal region by using existing techniques.

physics.ins-det

Combination of crystal growth with optical floating zone and evaluation of Nd3+:LaAlO3 crystals with the dynamic nuclear polarization of 139La and 27Al

Producing a polarized lanthanum (La) target with high polarization and long relaxation time is crucial for realizing time-reversal violation experiments using polarized neutron beams. We use a LaAlO3 crystal doped with a small amount of Nd3+ ions for the polarized lanthanum target. Optimizing the amount of Nd3+ ions is considerably important because the achievable polarization and relaxation time strongly depend on this amount. We established a fundamental method to grow single crystals of Nd3+:LaAlO3 using an optical floating zone method that employs halogen lamps and evaluated the crystals with the dynamic nuclear polarization (DNP) method for polarizing nuclear spins. Two crystal samples were grown by ourselves and evaluated with the DNP at 1.3 K and 2.3 T for the first time except for the target materials of protons. The enhancement of NMR signals for 139La and 27Al was successfully observed, and the enhancement factors were eventually 3.5+-0.3 and 13+-3 for the samples with Nd3+ ions of 0.05 and 0.01 mol%, respectively. These enhancement factors correspond to absolute vector polarizations of 0.27+-0.02% (Nd 0.05 mol%) and 1.4+-0.3% (Nd 0.01 mol%). Although the obtained polarizations are still low, they are acceptable as a first step. The combination scheme of the crystal growth and evaluation of the crystals is found to be effectively applicable for optimizing the amount of Nd3+ ions for improving the performance of the polarized target.

physics.ins-det

Sagnac-type neutron displacement-noise-free interferometeric gravitational-wave detector

The detection of low-frequency gravitational waves on Earth requires the reduction of displacement noise, which dominates the low-frequency band. One method to cancel test mass displacement noise is a neutron displacement-noise-free interferometer (DFI). This paper proposes a new neutron DFI configuration, a Sagnac-type neutron DFI, which uses a Sagnac interferometer in place of the Mach-Zehnder interferometer. We demonstrate that a sensitivity of the Sagnac-type neutron DFI is higher than that of a conventional neutron DFI with the same interferometer scale. This configuration is particularly significant for neutron DFIs with limited space for construction and limited flux from available neutron sources.

gr-qc

Development of Neutron Interferometer using Multilayer Mirrors and Measurements of Neutron-Nuclear Scattering Length with Pulsed Neutron Source

This study entailed the successful deployment of a novel neutron interferometer that utilizes multilayer mirrors. The apparatus facilitates a precise evaluation of the wavelength dependence of interference fringes utilizing a pulsed neutron source. Our interferometer achieved an impressive precision of 0.02 rad within a 20-min of recording time. Compared to systems using silicon crystals, the measurement sensitivity was maintained even when using a simplified disturbance suppressor. By segregating beam paths entirely, we achieved successful measurements of neutron-nuclear scattering lengths across various samples. The values measured for Si, Al, and Ti were in agreement with those found in the literature, while V showed a disparity of 45%. This discrepancy may be attributable to impurities encountered in previous investigations. The accuracy of measurements can be enhanced further by mitigating systematic uncertainties that are associated with neutron wavelength, sample impurity, and thickness. This novel neutron interferometer enables us to measure fundamental parameters, such as the neutron-nuclear scattering length of materials, with a precision that surpasses that of conventional interferometers.

physics.ins-det

Investigation of the neutron imaging applications using fine-grained nuclear emulsion

Neutron imaging is a non-destructive inspection technique with a wide range of applications. One of the important aspects concerning neutron imaging is achieving micrometer-scale spatial resolution. Developing a neutron detector with a high resolution is a challenging task. Neutron detectors, based on fine-grained nuclear emulsion, may be suitable for high resolution neutron imaging applications. High track density is a necessary requirement to improve the quality of neutron imaging. However, the available track analysis methods are difficult to apply under high track density conditions. Simulated images were used to determine the required track density for neutron imaging. It was concluded that a track density of the order of $10^4$ tracks per 100 $\times$ 100 $μ$m$^2$ is sufficient to utilize neutron detectors for imaging applications. The contrast resolution was also investigated for the image data sets with various track densities and neutron transmission rates. Moreover, experiments were performed for neutron imaging of the gadolinium-based gratings with known geometries. The structure of gratings was successfully resolved. The calculated 1$σ$ 10-90 \% edge response, using the gray scale optical images of the grating slit with a periodic structure of 9 $μ$m, was 0.945 $\pm$ 0.004 $μ$m.

physics.ins-det

Study on the reusability of fluorescent nuclear track detectors using optical bleaching

Fluorescent nuclear track detectors (FNTDs) based on Al${_2}$O${_3}$:C,Mg crystals are luminescent detectors that can be used for dosimetry and detection of charged particles and neutrons. These detectors can be utilised for imaging applications where a reasonably high track density, approximately of the order of 1 $\times$ $10^4$ tracks in an area of 100 $\times$ 100 $μ$m$^2$, is required. To investigate the reusability of FNTDs for imaging applications, we present an approach to perform optical bleaching under the required track density conditions. The reusability was assessed through seven irradiation-bleaching cycles. For the irradiation, the studied FNTD was exposed to alpha-particles from an $^{241}$Am radioactive source. The optical bleaching was performed by means of ultraviolet laser light with a wavelength of 355 nm. Three dedicated regions on a single FNTD with different accumulated track densities and bleaching conditions were investigated. After every irradiation-bleaching cycle, signal-to-noise ratio was calculated to evaluate FNTD performance. It is concluded that FNTDs can be reused at least seven times for applications where accumulation of a high track density is required.

physics.ins-det

Displacement-noise-free interferometeric gravitational-wave detector using unidirectional neutrons with four speeds

For further gravitational wave (GW) detections, it is significant to invent a technique to reduce all kinds of mirror displacement noise dominant at low frequencies for ground-based detectors. The neutron displacement-noise-free interferometer (DFI) is one of the tools to reduce all the mirror displacement noise at lower frequencies. In this paper, we describe a further simplified configuration of a neutron DFI in terms of neutron incidence direction. In the new configuration, neutrons enter the interferometer with unidirectional incidence at four speeds as opposed to two bidirectional incidences of opposite directions at two speeds as reported previously. This simplification of the neutron DFI is significant for proof-of-principle experiments.

gr-qc

The Precision nEDM Measurement with UltraCold Neutrons at TRIUMF

The TRIUMF Ultra-Cold Advanced Neutron (TUCAN) collaboration aims at a precision neutron electric dipole moment (nEDM) measurement with an uncertainty of $10^{-27}\,e\cdot\mathrm{cm}$, which is an order-of-magnitude better than the current nEDM upper limit and enables us to test Supersymmetry. To achieve this precision, we are developing a new high-intensity ultracold neutron (UCN) source using super-thermal UCN production in superfluid helium (He-II) and a nEDM spectrometer. The current development status of them is reported in this article.

physics.ins-det

Study of Thin Iron Films for Polarization Analysis of Ultracold Neutrons

The TUCAN (TRIUMF Ultra-Cold Advanced Neutron) collaboration aims to search for the neutron electric dipole moment (nEDM) with unprecedented precision. One of the essential elements for the nEDM measurement is a polarization analyzer of ultracold neutrons (UCNs), whose main component is a magnetized thin iron film. Several thin iron films were deposited on aluminum and silicon ubstrates and were characterized by vibrating sample magnetometry and cold-neutron reflectometry. A magnetic field required to saturate the iron film is $\sim$12 kA/m for those on the aluminum substrates and 6.4 kA/m for the silicon substrates. The magnetic potential of the iron films on the Si substrate was estimated to be 2 T by the neutron reflectometry, which is sufficient performance for an UCN polarization analyzer of the nEDM measurement.

physics.ins-det

A Novel Nuclear Emulsion Detector for Measurement of Quantum States of Ultracold Neutrons in the Earth's Gravitational Field

Hypothetical short-range interactions could be detected by measuring the wavefunctions of ultracold neutrons (UCNs) on a mirror bounded by the Earth's gravitational field. The Searches require detectors with higher spatial resolution. We are developing a UCN detector for the with a high spatial resolution, which consists of a Si substrate, a thin converter layer including $^{10}$B$_{4}$C, and a layer of fine-grained nuclear emulsion. Its resolution was estimated to be less than 100 nm by fitting tracks of either $^{7}$Li nuclei or $α$-particles, which were created when neutrons interacted with the $^{10}$B$_{4}$C layer. For actual measurements of the spatial distributions, the following two improvements were made: The first was to establish a method to align microscopic images with high accuracy within a wide region of 65 mm $\times$ 0.2 mm. We created reference marks of 1 $μ$m and 5 $μ$m diameter with an interval of 50 $μ$m and 500 $μ$m, respectively, on the Si substrate by electron beam lithography and realized a position accuracy of less than 30 nm. The second was to build a holder that could maintain the atmospheric pressure around the nuclear emulsion to utilize it under vacuum during exposure to UCNs. The intrinsic resolution of the improved detector was estimated by evaluating the blur of a transmission image of a gadolinium grating taken by cold neutrons as better than 0.56 $\pm$ 0.08 $μ$m, which included the grating accuracy. A test exposure to UCNs was conducted to obtain the spatial distribution of UCNs in the Earth's gravitational field. Although the test was successful, a blurring of 6.9 $μ$m was found in the measurements, compared with a theoretical curve. We identified the blurring caused by the refraction of UCNs due to the roughness of the upstream surface of the substrate. Polishing of the surface makes the resolution less than 100 nm.

physics.ins-det

Neutron displacement noise-free interferometer for gravitational-wave detection

An interferometer design that cancels all displacement noises of its test masses and maintains a gravitational-wave (GW) signal by combining multiple detector signals is called a displacement noise-free interferometer (DFI). The idea has been considered previously for a laser interferometer. However, a limitation of a laser DFI is that its sensitive frequency band is too high for astrophysical GW sources, $\sim 10^5\,{\rm Hz}$ even for a kilometer-sized interferometer. To circumvent this limitation, in this paper, we propose a neutron DFI, in which neutrons are used instead of light. Since neutrons have velocities much lower than the speed of light, the sensitive frequency band of a neutron DFI can be lowered down to $\sim 10^{-1}\,{\rm Hz}$. Therefore, a neutron DFI can be utilized for detecting GWs that are inaccessible by an ordinary laser interferometer on the ground.

gr-qc