Searcharxiv⌕ Search

arXiv subjects

Masahiro Tsujimoto

Publications and source records attributed to Masahiro Tsujimoto.

At least 19 recordsLinked to original sources

Fe Kα equivalent-width mapping with 3D radiative transfer calculation: A general model and application to the RS Canum Venaticorum-type stars with XRISM/Resolve

The Fe K $α$ fluorescence line at 6.4 keV has long been used to probe the relative geometry between photoionizing X-ray sources and surrounding cold material in a wide range of astrophysical systems. With the advent of the X-ray microcalorimeter XRISM/Resolve, Fe K $α$ lines with equivalent widths down to $\sim 5$ eV-previously inaccessible-are now detectable, and even non-detections can place upper limits of a few eV, making non-detections themselves valuable for constraining the geometry. Considering that Fe K $α$-based geometric diagnostics are entering a new stage in the microcalorimeter era, we present Fe K $α$ equivalent-width maps computed with the three-dimensional Monte Carlo radiative-transfer code SKIRT for a generalized configuration consisting of a spherical reflector of radius $R_{*}$ and a point source located at a height $h$ above the surface. The equivalent-width maps exhibit two characteristic features: (1) an increase toward the center of the projected surface of the sphere; and (2) an overall decrease with increasing $h/R_{*}$. The key point is that we confirm these features for equivalent widths of $< 40$ eV, a regime that has become accessible for the first time thanks to the improved detection threshold from $\sim 50$ eV with Chandra/HETG to $\sim 5$ eV with XRISM/Resolve. As an illustrative application, we compare the maps with XRISM/Resolve spectra of three RS Canum Venaticorum-type stars (GT Muscae, $σ$ Geminorum, and HR 1099) and constrain the locations of the flare loop and coronal bright points in these systems. Because the maps are constructed for a highly generalized point-source--spherical-reflector geometry, they are readily applicable to many other objects, including X-ray binaries and cataclysmic variables.

astro-ph.HE↗

Orbital motion detected in gamma Cas Fe K emission lines

A subset of Be stars, typified by the naked-eye star gamma Cas, exhibits unusually bright and hard X-ray emission, the origin of which has remained debated for five decades. We performed high-resolution X-ray spectroscopic monitoring of gamma Cas with the Resolve instrument aboard the X-Ray Imaging and Spectroscopy Mission (XRISM). X-ray lines from the ultra-hot plasma and fluorescence from cooler material exhibit Doppler shifts consistent with orbital motion, not of the Be star itself, but of its low-mass companion (previously shown to be a white dwarf). This first evidence of orbital motion for the hard X-ray emitting plasma uniquely links it to the scenario of accretion onto the white dwarf companion. The modest line broadening further indicates that fluorescence occurs on the white dwarf surface and excludes X-ray generation in the inner parts of an accretion disc. Our findings identify gamma Cas and its analogues as the previously elusive, but long predicted class of binaries composed of a Be and a white dwarf. Identifying the origin of the hard X-rays from gamma Cas and its analogues, which represent about 10% of early-type Be stars, provides a key input for population synthesis models of massive binary evolution.

astro-ph.SR↗

Energy shift of Fe-K fluorescence lines due to low ionization demonstrated with XRISM in Centaurus X-3

The Fe K$α$ fluorescence line at 6.4 keV is a powerful probe of cold matter surrounding X-ray sources and has been widely used in various astrophysical contexts. The X-ray microcalorimeter spectrometer onboard XRISM can measure line shifts with unprecedented precision of $\sim$0.2 eV, equivalent to a line-of-sight velocity of $\sim$10 km s$^{-1}$. At this level of accuracy, however, several factors that influence the line energy must be carefully considered prior to astrophysical interpretation. One such important factor is the ionization degree, Fe$^{q+}$. The K$α$ line shifts redward by $\sim$4 eV as $q$ increases from 0 (neutral) to 8 (Ar-like). Additionally, the accompanying Fe K$β$ line at 7.06 keV shifts blueward by $\sim$30 eV from $q=0$ to 8. We demonstrate that this effect is actually observable in the XRISM data of the high-mass X-ray binary Centaurus X-3 (Cen X-3). We advocate that the differential energy shift between the K$α$ and K$β$ line provides a robust estimate of $q$ by decoupling from other effects that shift the two lines in the same direction. We derived $q \sim 5$ (Sc-like) for the fluorescing matter by comparing the observation with atomic structure calculations of our own and in the literature. By accounting for the derived charge state and the corresponding shift in the rest-frame line energy, we made corrections for this effect and reached a consistent residual shift among the K$α$, K$β$, and the optical measurement attributable to the systemic velocity of the system. Consequently, we obtained a new constraint on the location of the cold matter. This ionization effect needs to be assessed in all use cases of the Fe K$α$ line shift beyond Cen X-3, and the proposed metric is generally applicable to all of them.

astro-ph.HE↗

XRISM view of a stellar flare: High-resolution Fe K spectra of HR 1099, an RS CVn-type star

A high-resolution X-ray spectroscopic observation was made of the RS CVn-type binary star HR 1099 using the Resolve instrument onboard XRISM for its calibration purposes. During the $\sim$400 ks telescope time covering 1.5 binary orbit, a flare lasting for $\sim$100 ks was observed with a released X-ray radiation energy of $\sim 10^{34}$ erg, making it the first stellar flare ever observed with an X-ray microcalorimeter spectrometer. The flare peak count rate is 6.4 times higher than that in quiescence and is distinguished clearly in time thanks to the long telescope time. Many emission lines were detected in the 1.7--10 keV range both in the flare and quiescent phases. Using the high spectral resolution of Resolve in the Fe K band (6.5--7.0 keV), we resolved the inner-shell lines of Fe XIX--XXIV as well as the outer-shell lines of Fe XXV--XXVI. These lines have peaks in the contribution functions at different temperatures over a wide range, allowing us to construct the differential emission measure (DEM) distribution over the electron temperature of 1--10 keV (roughly 10--100 MK) based only on Fe lines, thus without an assumption of the elemental abundance. The reconstructed DEM has a bimodal distribution, and only the hotter component increased during the flare. The elemental abundance was derived based on the DEM distribution thus constructed. A significant abundance increase was observed during the flare for Ca and Fe, which are some of the elements with the lowest first ionization potential among those analyzed, but not for Si, S, and Ar. This behavior is seen in some giant solar flares and the present result is a clear example in stellar flares.

astro-ph.SR↗

Fe XVIII-XXIV K beta Inner-shell Absorption Lines in the X-ray Spectra of Neutron Star and Black Hole Binaries with XRISM

The advent of the X-ray microcalorimeter spectrometer Resolve onboard the XRISM space telescope opened a new era for high-resolution X-ray spectroscopy of astrophysical plasmas. Many spectral features were newly detected, including the K alpha and K beta inner-shell transition lines of mildly ionized (F- to Li-like) Fe at 6-8 keV in the spectra of X-ray binaries and active galactic nuclei. The widely used atomic databases contain information on the K alpha but not K beta lines of these ions. We conducted the atomic structure calculation using FAC to derive the Fe K alpha and K beta lines and verified the result against ground experiments and other calculations of the Fe K alpha lines. We then implemented the Fe K beta lines in a radiative transfer code (cloudy) and compared the synthesized and observed spectra with XRISM. A reasonably good agreement was obtained between the observation and the ab initio calculations. This exemplifies the need to expand the atomic databases to interpret astrophysical spectra.

astro-ph.HE↗

In orbit operation of Resolve Filter Wheel and MXS

The Resolve soft X-ray spectrometer is the high spectral resolution microcalorimeter spectrometer for the XRISM mission. In the beam of Resolve there is a filter wheel containing \xray{} filters. In the beam also is an active calibration source (the modulated X-ray source (MXS) that can provide pulsed \xray s to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one $^{55}$Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of a MXS are highly configurable. Furthermore, the switch--on time is synchronized with the spacecraft's internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of a MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, this article will discuss the calibration source and the filter performance in--flight and compare with the transmission curves present in the Resolve calibration database.

astro-ph.IM↗

Benchmark of the Fe XXV R ratio in photoionized plasma during eclipse of Centaurus X-3 with XRISM/Resolve

The R ratio is a useful diagnostic of the X-ray emitting astrophysical plasmas defined as the intensity ratio of the forbidden over the inter-combination lines in the K$α$ line complex of He-like ions. The value is altered by excitation processes (electron impact or UV photoexcitation) from the metastable upper level of the forbidden line, thereby constraining the electron density or UV field intensity. The diagnostic has been applied mostly in electron density constraints in collisionally ionized plasmas using low-Z elements as was originally proposed for the Sun (Gabriel & Jordan (1969a, MNRAS, 145, 241)), but it can also be used in photoionized plasmas. To make use of this diagnostic, we need to know its value in the limit of no excitation of metastables (R$_0$), which depends on the element, how the plasmas are formed, how the lines are propagated, and the spectral resolution affecting line blending principally with satellite lines from Li-like ions. We benchmark R$_0$ for photoionized plasmas by comparing calculations using radiative transfer codes and observation data taken with the Resolve X-ray microcalorimter onboard XRISM. We use the Fe XXV He$α$ line complex of the photo-ionized plasma in Centaurus X-3 observed during eclipse, in which the plasma is expected to be in the limit of no metastable excitation. The measured R$ = 0.65 \pm 0.08$ is consistent with the value calculated using xstar for the plasma parameters derived from other line ratios of the spectrum. We conclude that the R ratio diagnostic can be used for high-$Z$ elements such as Fe in photoionized plasmas, which has wide applications in plasmas around compact objects at various scales.

astro-ph.HE↗

The 2025 Release of Cloudy

We present the 2025 release of the spectral synthesis code Cloudy, highlighting significant enhancements to the scope and accuracy of the physics which have been made since the previous release. A major part of this development involves resolving the Lyman $α$ line into $j$-resolved fine-structure doublets, making Cloudy of use to the X-ray community. On this front, we have also updated inner-shell ionization line energies and incorporated the 1 keV feature commonly observed in X-ray binaries. Additionally, we update our in-house database, Stout, for the carbon isoelectronic sequence, improving Cloudy microphysical calculations for all wavelengths. We have also extended the molecular network by adding new silicon-bearing species, titanium-related reactions, and phosphorus-containing molecules, enhancing Cloudy's ability to model the complex chemistry relevant to rapidly growing field of exoplanet atmospheres. Finally, we outline future developments aimed at maximizing the scientific return from the current and upcoming generation of observatories, including XRISM, JWST, Roman, the Habitable Worlds Observatory (HWO) and NewAthena.

astro-ph.GA↗

Detection of the orbital modulation of Fe K$α$ fluorescence emission in Centaurus X-3 using the high-resolution spectrometer Resolve onboard XRISM

The Fe K$α$ fluorescence line emission in X-ray spectra is a powerful diagnostic tool for various astrophysical objects to reveal the distribution of cold matter around photo-ionizing sources. The advent of the X-ray microcalorimeter onboard the \textit{XRISM} satellite will bring new constraints on the emission line. We present one of the first such results for the high-mass X-ray binary Centaurus X-3, which is composed of an O-type star and a neutron star (NS). We conducted a 155 ks observation covering an entire binary orbit. A weak Fe K$α$ line was detected in all orbital phases at an equivalent width (EW) of 10--20 eV. We found for the first time that its radial velocity (RV) is sinusoidally modulated by the orbital phase. The RV amplitude is 248 $\pm$ 13 km s$^{-1}$, which is significantly smaller than the value (391 km s$^{-1}$) expected if the emission is from the NS surface, but is consistent if the emission takes place at the O star surface. We discuss several possibilities of the line production site, including the NS surface, O star surface, O star wind, and accretion stream from the O star to the NS. We ran radiative transfer calculation for some of them assuming spherically-symmetric density and velocity profiles and an isotropic distribution of X-ray emission from the NS. None of them explains the observed EW and velocity dispersion dependence on the orbital phase, suggesting that more elaborated modeling is needed. In other words, the present observational results have capability to constrain deviations from these assumptions.

astro-ph.HE↗

Spectroscopic diagnostics of high-temperature plasma in stellar corona using Fe XXIV--XXVI K-shell lines with XRISM

The RS CVn type binary star GT Mus was observed during its quiescence using the Resolve X-ray microcalorimeter spectrometer onboard XRISM. The main and satellite lines of the Fe XXIV--XXVI K-shell transitions were resolved for the first time from stellar sources. We conducted line ratio analysis to investigate any deviations from collisional onization equilibrium (CIE) and Maxwell electron energy distribution with a single-temperature. By using five combinations of direct excitation lines and dielectronic recombination satellite lines in three line complexes (Fe He$α$, Ly$α$, and He$β$), we found that the plasma is well characterized by two-temperature thermal plasmas with temperatures of 1.7 and 4.3 keV, which is consistent with a thermal broadening of Fe XXV and the broadband fitting results in the 1.7--10 keV band. Other forms of deviation from a single-temperature plasma, such as different ionization and electron temperatures or the $κ$ distribution for the electron energy distributions, are not favored, which is reasonable for stellar coronae at quiescence. This study demonstrates the utility of the Fe K-shell line ratio diagnostics to probe plasma conditions using X-ray microcalorimeters.

astro-ph.HE↗

Outflowing photoionized plasma in Circinus X-1 using the high-resolution X-ray spectrometer Resolve onboard XRISM and the radiative transfer code cloudy

High-resolution X-ray spectroscopy is a key to understanding the mass inflow and outflow of compact objects. Spectral lines carry information about the ionization, density, and velocity structures through their intensity ratios and profiles. They are formed in non-local thermodynamic equilibrium conditions under the intense radiation field from the compact objects, thus radiative transfer (RT) calculation is a requisite for proper interpretations. We present such a study for a low-mass X-ray binary, Circinus X-1, from which the P Cygni profile was discovered using the X-ray grating spectrometer onboard Chandra. We observed the source using the X-ray microcalorimeter onboard XRISM at an orbital phase of 0.93-0.97 and revealed many spectral features unidentified before; the higher series transitions (n to 1; n > 2) of highly-ionized (H- and He-like) S, Ca, Ar, and Fe in emission and absorption, the Fe Kα and K\b{eta} inner-shell excitation absorption of mildly-ionized (O- to Li-like) Fe, and resolved fine-structure level transitions in the Fe Lyα and Heα complexes. They blend with each other at different velocity shifts on top of apparently variable continuum emission that changed its flux by an order of magnitude within a 70 ks telescope time. Despite such complexity in the observed spectra, most of them can be explained by a simple model consisting of the photoionized plasma outflowing at ~300 km s-1 and the variable blocking material in the line of sight of the incident continuum emission from the accretion disk. We demonstrate this with the aid of the RT code cloudy for the line ratio diagnostics and spectral fitting. We further constrain the physical parameters of the outflow and argue that the outflow is launched close to the outer edge of the accretion disk and can be driven radiatively by being assisted by the line force calculated using the RT simulation.

astro-ph.HE↗

New Insights with XRISM & Cloudy: A novel Column Density Diagnostic

We present a simple, yet powerful column density diagnostic for plasmas enabled by X-ray microcalorimeter observations. With the recent developments of the spectral simulation code Cloudy, inspired by the high spectral resolution of the X-Ray Imaging and Spectroscopy Mission (XRISM) and the Advanced Telescope for High Energy Astrophysics (Athena), we make predictions for the intensity ratio of the resolved fine-structure lines Ly$α_1$ and Ly$α_2$ of H-like ions. We show that this ratio can be observationally constrained and used as a plasma column density indicator. We demonstrate this with a XRISM observation of the high-mass X-ray binary Centaurus X-3. This diagnostic is useful for a wide range of X-ray emitting plasmas, either collisionally or radiatively ionized.

astro-ph.HE↗

Optimization of x-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The XRISM (X-Ray Imaging and Spectroscopy Mission) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an x-ray microcalorimeter detector, which was designed to achieve a high-resolution ($\leq$7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of $< 2 \times 10^{-3}$ s$^{-1}$ keV$^{-1}$ (0.3--12.0 keV), which is equivalent to only one background event per spectral bin per 100 ks exposure. Event screening to discriminate x-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding x-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer (SXS) onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to $1.8 \times 10^{-3}$ s$^{-1}$ keV$^{-1}$ meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of x-ray events and show that it further reduces the background rate particularly in the $<$2 keV band. Over 0.3--12 keV, the background rate becomes $1.0 \times 10^{-3}$ s$^{-1}$ keV$^{-1}$.

astro-ph.IM↗

High count rate effects in event processing for XRISM/Resolve x-ray microcalorimeter

The spectroscopic performance of x-ray instruments can be affected at high count rates. The effects and mitigation in the optical chain, such as x-ray attenuation filters or de-focusing mirrors, are widely discussed, but those in the signal chain are not. Using the Resolve x-ray microcalorimeter onboard the XRISM satellite, we discuss the effects observed during high count rate measurements and how these can be modeled. We focus on three instrumental effects that impact performance at high count rate: CPU limit, pile up, and electrical cross talk. High count rate data were obtained during ground testing using the flight model instrument and a calibration x-ray source. A simulated observation of GX 13+1 is presented to illustrate how to estimate these effects based on these models for observation planning. The impact of these effects on high count rate observations is discussed.

astro-ph.IM↗

High count rate effects in event processing for XRISM/Resolve x-ray microcalorimeter: I. Ground test

The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. In this study, we utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.

astro-ph.IM↗

Intrinsic line profiles for X-ray fluorescent lines in SKIRT

We included the intrinsic line profiles of the strongest fluorescent lines in the X-ray radiative transfer code SKIRT to model the cold-gas structure and kinematics based on high-resolution line observations from XRISM/Resolve and Athena/X-IFU. The intrinsic line profiles of the Ka and Kb lines of Cr, Mn, Fe, Co, Ni, and Cu were implemented based on a multi-Lorentzian parameterisation and line energies are sampled from these Lorentzian components during the radiative transfer routine. In the optically thin regime, the SKIRT results match the intrinsic line profiles as measured in the laboratory. With a more complex 3D model that also includes kinematics, we find that the intrinsic line profiles are broadened and shifted to an extent that will be detectable with XRISM/Resolve; this model also demonstrates the importance of the intrinsic line shapes for constraining kinematics. We find that observed line profiles directly trace the cold-gas kinematics, without any additional radiative transfer effects. With the advent of the first XRISM/Resolve data, this update to the X-ray radiative transfer framework of SKIRT is timely and provides a unique tool for constraining the velocity structure of cold gas from X-ray microcalorimeter spectra.

astro-ph.HE↗

High-velocity blue-shifted Fe XXV He$α$ line during a superflare of the RS CVn-type star IM Peg

Monitor of All-sky X-ray Image (MAXI) detected a superflare, releasing $5\times 10^{37}$ erg in 2$-$10 keV, of the RS CVn-type star IM Peg at 10:41 UT on 2023 July 23 with its Gas Slit Camera (GSC; 2$-$30 keV). We conducted X-ray follow-up observations of the superflare with Neutron Star Interior Composition ExploreR (NICER; 0.2$-$12 keV) starting at 16:52 UT on July 23 until 06:00 UT on August 2. NICER X-ray spectra clearly showed emission lines of the Fe XXV He$α$ and Fe XXVI Ly$α$ for $\sim 1.5$ days since the MAXI detection. The Fe XXV He$α$ line was blue-shifted with its maximum Doppler velocity reaching $-2200 \pm 600$ $\mathrm{km \: s^{-1}}$, suggesting an upward-moving plasma during the flare, such as a coronal mass ejection (CME) and/or chromospheric evaporation. This is the first case that the Fe XXV He$α$ line is blue-shifted during a stellar flare and its velocity overwhelmingly exceeds the escape velocity of the star ($-230$ $\mathrm{km \: s^{-1}}$). One hour before the most pronounced blueshift detection, a signature of reheating the flare plasma was observed. We discuss the origin of the blueshift, a CME or high-velocity chromospheric evaporation.

astro-ph.SR↗

Investigation of non-equilibrium ionization plasma during a giant flare of UX Arietis triggered with MAXI and observed with NICER

We detected a giant X-ray flare from the RS-CVn type binary star UX Ari using MAXI on 2020 August 17 and started a series of NICER observations 89 minutes later. For a week, the entire duration of the flare was covered with 32 snapshot observations including the rising phase. The X-ray luminosity reached 2$\times$10$^{33}$ erg s$^{-1}$ and the entire energy release was $\sim 10^{38}$ erg in the 0.5--8.0~keV band. X-ray spectra characterized by continuum emission with lines of Fe XXV He$α$ and Fe XXVI Ly$α$ were obtained. We found that the temperature peaks before that of the flux, which suggests that the period of plasma formation in the magnetic flare loop was captured. Using the continuum information (temperature, flux, and their delay time), we estimated the flare loop size to be $\sim 3 \times 10^{11}$ cm and the peak electron density to be $\sim 4\times10^{10}$ cm$^{-3}$. Furthermore, using the line ratio of Fe XXV and Fe XXVI, we investigated any potential indications of deviation from collisional ionization equilibrium (CIE). The X-ray spectra were consistent with CIE plasma throughout the flare, but the possibility of an ionizing plasma away from CIE was not rejected in the flux rising phase.

astro-ph.SR↗