SearcharxivSearch

arXiv subjects

Masaki Ando

Publications and source records attributed to Masaki Ando.

At least 19 recordsLinked to original sources

A Polarization-Decomposed Method for Simulating Inhomogeneous Birefringence in Laser-Interferometric Gravitational-Wave Detectors

Birefringence in test mass substrates is an emerging limitation for current and future laser-interferometric gravitational-wave detectors, particularly as detectors move toward higher circulating power, cryogenic operation, and crystalline optical materials. Spatially varying birefringence alters both the polarization state and spatial mode content of the intracavity field, reducing interference contrast and coupling into length and alignment control signals. Accurate modeling of these effects is complicated by the fact that most frequency-domain simulation tools employ scalar modal propagation and lack native support for polarization and two-dimensional substrate maps. In this work, we present a practical and general method for simulating inhomogeneous birefringence without modifying existing simulation frameworks. The approach represents the two polarization components as independent scalar fields and introduces their coupling through an equivalent triple-Mach-Zehnder construction that reproduces the Jones matrix of a birefringent medium. We demonstrate the method using realistic birefringence maps of the KAGRA sapphire input test masses. The technique is compatible with any frequency-domain interferometer model and enables efficient birefringence studies for next-generation gravitational-wave detectors.

physics.ins-det

Adjusting optical cavity birefringence with wavelength tunable laser for axion searches

Axions have attracted attention as promising candidates for dark matter (DM). Although axions have been intensively searched for, they have not been observed yet. Recently, novel experiments to search for axion DM have been proposed that use optical cavities to amplify polarization rotation of laser light induced by the axion-photon interaction. One such experiment employs a ring cavity composed of four mirrors. However, its sensitivity to the axion-photon coupling $g_{a\gamma}$ in the low axion mass region is limited due to a reflection phase difference between s- and p-polarizations. In this paper, we propose a new method to improve the sensitivity using zero-phase shift mirrors and a wavelength tunable laser. Moreover, the laser makes it easier to scan the high axion mass region by tuning the reflection phase difference between s- and p-polarizations. We experimentally confirmed that the phase difference generated upon reflection on a zero phase shift mirror satisfied the requirement of $8.6 \times 10^{-3}~\mathrm{deg}$, which corresponds to the half width at half maximum (HWHM) of the cavity for p-polarization with the mirror fixed on a folded cavity and a wavelength tunable laser.

hep-ex

SILVIA: Ultra-precision formation flying demonstration for space-based interferometry

We propose SILVIA (Space Interferometer Laboratory Voyaging towards Innovative Applications), a mission concept designed to demonstrate ultra-precision formation flying between three spacecraft separated by 100 m. SILVIA aims to achieve sub-micrometer precision in relative distance control by integrating spacecraft sensors, laser interferometry, low-thrust and low-noise micro-propulsion for real-time measurement and control of distances and relative orientations between spacecraft. A 100-meter-scale mission in a near-circular low Earth orbit has been identified as an ideal, cost-effective setting for demonstrating SILVIA, as this configuration maintains a good balance between small relative perturbations and low risk for collision. This mission will fill the current technology gap towards future missions, including gravitational wave observatories such as DECIGO (DECihertz Interferometer Gravitational wave Observatory), designed to detect the primordial gravitational wave background, and high-contrast nulling infrared interferometers like LIFE (Large Interferometer for Exoplanets), designed for direct imaging of thermal emissions from nearby terrestrial planet candidates. The mission concept and its key technologies are outlined, paving the way for the next generation of high-precision space-based observatories.

astro-ph.IM

Initial acquisition requirements for optical cavities in the space gravitational wave antennae DECIGO and B-DECIGO

DECIGO (DECi-hertz Interferometer Gravitational Wave Observatory) is a space-based gravitational wave antenna concept targeting the 0.1-10 Hz band. It consists of three spacecraft arranged in an equilateral triangle with 1,000 km sides, forming Fabry-P\'erot cavities between them. A precursor mission, B-DECIGO, is also planned, featuring a smaller 100 km triangle. Operating these cavities requires ultra-precise formation flying, where inter-mirror distance and alignment must be precisely controlled. Achieving this necessitates a sequential improvement in precision using various sensors and actuators, from the deployment of the spacecraft to laser link acquisition and ultimately to the control of the Fabry-P\'erot cavities to maintain resonance. In this paper, we derive the precision requirements at each stage and discuss the feasibility of achieving them. We show that the relative speed between cavity mirrors must be controlled at the sub-micrometer-per-second level and that relative alignment must be maintained at the sub-microradian level to obtain control signals from the Fabry-P\'erot cavities of DECIGO and B-DECIGO.

gr-qc

TOrsion-Bar Antenna: A Ground-Based Detector for Low-Frequency Gravity Gradient Measurement

The Torsion-Bar Antenna (TOBA) is a torsion pendulum-based gravitational detector developed to observe gravitational waves in frequencies between 1 mHz and 10 Hz. The low resonant frequency of the torsion pendulum enables observation in this frequency band on the ground. The final target of TOBA is to observe gravitational waves with a 10 m detector and expand the observation band of gravitational waves. In this paper, an overview of TOBA, including the previous prototype experiments and the current ongoing development, is presented.

gr-qc

Significance of Fabry-Perot cavities for space gravitational wave antenna DECIGO

The future Japanese project for the detection of gravitational waves in space is planned as DECIGO. To achieve various scientific missions, including the verification of cosmic inflation through the detection of primordial gravitational waves as the main objective, DECIGO is designed to have high sensitivity in the frequency band from $0.1$ to $1$ Hz, with arms of length 1000 km. Furthermore, the use of the Fabry-Perot cavity in these arms has been established for the DECIGO project. In this paper, we scrutinize the significance of the Fabry-Perot cavity for promoting this project, with a focus on the possibility of observing gravitational waves from cosmic inflation and binary compact star systems as indicators. The results show that using the Fabry-Perot cavity is extremely beneficial for detecting them, and it is anticipated to enable the opening of a new window in gravitational wave astronomy.

gr-qc

First results of axion dark matter search with DANCE

Axions are one of the well-motivated candidates for dark matter, originally proposed to solve the strong CP problem in particle physics. Dark matter Axion search with riNg Cavity Experiment (DANCE) is a new experimental project to broadly search for axion dark matter in the mass range of $10^{-17}~\mathrm{eV} < m_a < 10^{-11}~\mathrm{eV}$. We aim to detect the rotational oscillation of linearly polarized light caused by the axion-photon coupling with a bow-tie cavity. The first results of the prototype experiment, DANCE Act-1, are reported from a 24-hour observation. We found no evidence for axions and set 95% confidence level upper limit on the axion-photon coupling $g_{a γ} \lesssim 8 \times 10^{-4}~\mathrm{GeV^{-1}}$ in $10^{-14}~\mathrm{eV} < m_a < 10^{-13}~\mathrm{eV}$. Although the bound did not exceed the current best limits, this optical cavity experiment is the first demonstration of polarization-based axion dark matter search without any external magnetic field.

hep-ex

Cross-Correlated Force Measurement for Thermal Noise Reduction in Torsion Pendulum

The torsion pendulum is a prevailing instrument for measuring small forces acting on a solid body or those between solid bodies. While it offers powerful advantages, the measurement precision suffers from thermal noises of the suspending wires giving rise to stochastic torque noises. This paper proposes a new scheme to reduce the effect of such noise by employing a double torsion pendulum and cross-correlation technique based on the theoretical analysis that the thermal torque noise appears at each end of the suspending wire differentially. Cross-correlating two synthesized data streams which are composed of the rotation angles of two torsion stages, it yields the power spectral density estimate of external forces acting on the lower stage with the reduced effect from the thermal torque noises. As an example use case, we discuss the application to the study on the coupling strength of ultra light dark matter to standard model particles. Our evaluation indicates that the upper limit may be improved by an order of magnitude than the previous experiments at 2 mHz, which corresponds to about $8\times10^{-18}$ eV.

astro-ph.IM

Wavefront Sensing with a Coupled Cavity for Torsion-Bar Antenna

Torsion-Bar Antenna (TOBA) is a ground-based gravitational wave detector using torsion pendulums. TOBA can detect intermediate-mass black hole binary mergers, gravitational wave stochastic background, and Newtonian noise, and is useful for earthquake early warning. A prototype detector Phase-III TOBA with 35 cm-scale pendulums is under development to demonstrate noise reduction. The target strain sensitivity is set to $1\times10^{-15}\,{/\sqrt{\rm Hz}}$ between 0.1 Hz--10 Hz. A new scheme of wavefront sensing with a coupled cavity was proposed to measure the pendulum rotation as low as $5\times10^{-16}\,{{\rm rad}/\sqrt{\rm Hz}}$ for Phase-III TOBA. In our method, an auxiliary cavity is used to enhance the first-order Hermite--Gaussian mode in a main cavity. Experimental demonstration is ongoing to confirm the feasibility of angular signal amplification and establish a method for locking a coupled cavity. We evaluated the performance of the coupled cavity and concluded that angular signal amplification would be feasible with this sensor. The coupled cavity was successfully locked to the resonance by the Pound--Drever--Hall technique with two modulation frequencies.

physics.ins-det

Angular trapping of a linear-cavity mirror with an optical torsional spring

Optomechanical systems have been attracting intensive attention in various physical experiments. With an optomechanical system, the displacement of or the force acting on a mechanical oscillator can be precisely measured by utilizing optical interferometry. As a mechanical oscillator, a suspended mirror is often used in over milligram scale optomechanical systems. However, the tiny suspended mirror in a linear cavity can be unstable in its yaw rotational degree of freedom due to optical radiation pressure. This instability curbs the optical power that the cavity can accumulate in it, and imposes a limitation on the sensitivity. Here, we show that the optical radiation pressure can be used to trap the rotational motion of the suspended mirror without additional active feedback control when the $g$ factors of the cavity are negative and one mirror is much heavier than the other one. Furthermore, we demonstrate experimentally the validity of the trapping. We measured the rotational stiffness of a suspended tiny mirror with various intracavity power. The result indicates that the radiation pressure of the laser beam inside the cavity actually works as a positive restoring torque. Moreover, we discuss the feasibility of observing quantum radiation pressure fluctuation with our experimental setup as an application of our trapping configuration.

quant-ph

3G R&D: R&D for the Next Generation of Ground-based Gravitational-wave Detectors

To deliver on the promise of next generation gravitational-wave observatories, a sustained and coordinated detector research and development program is required. This report examines in detail the wide range of nearer- and longer-term detector R&D programs needed for next generation GW detectors commensurate with the key science targets presented in "The Next Generation Global Gravitational Wave Observatory: The Science Book", including considerations of site selection and large-scale vacuum infrastructure. The report makes a series of detailed recommendations on the needed advances in detector technology and the timescales needed to achieve those advances. It also identifies areas where larger-scale globally coordinated R&D efforts will be critical to ensuring success while minimizing costs. This report is the third in a six part series of reports by the GWIC 3G Subcommittee: i) Expanding the Reach of Gravitational Wave Observatories to the Edge of the Universe, ii) The Next Generation Global Gravitational Wave Observatory: The Science Book, iii) 3G R&D: R&D for the Next Generation of Ground-based Gravitational Wave Detectors (this report), iv) Gravitational Wave Data Analysis: Computing Challenges in the 3G Era, v) Future Ground-based Gravitational-wave Observatories: Synergies with Other Scientific Communities, and vi) An Exploration of Possible Governance Models for the Future Global Gravitational-Wave Observatory Network.

gr-qc

First observation and analysis of DANCE: Dark matter Axion search with riNg Cavity Experiment

Dark matter Axion search with riNg Cavity Experiment (DANCE) was proposed to search for axion dark matter [Phys. Rev. Lett. 121, 161301 (2018)]. We aim to detect the rotation and oscillation of optical linear polarization caused by axion-photon coupling with a bow-tie cavity. DANCE can improve the sensitivity to axion-photon coupling constant $g_{a γ}$ for axion mass $m_a < 10^{-10}~\rm{eV}$ by several orders of magnitude compared to the best upper limits at present. A prototype experiment DANCE Act-1 is ongoing to demonstrate the feasibility of the method and to investigate technical noises. The optics was assembled and the performance of the cavity was evaluated. The first 12-day observation was successfully performed in May 2021. We reached $3 \times 10^{-6}~\rm{rad/\sqrt{Hz}}$ at $10~\rm{Hz}$ in the one-sided amplitude spectral density of the rotation angle of linear polarization.

physics.ins-det

Dark matter Axion search with riNg Cavity Experiment DANCE: Design and development of auxiliary cavity for simultaneous resonance of linear polarizations

Axion-like particles (ALPs) are undiscovered pseudo-scalar particles that are candidates for ultralight dark matter. ALPs interact with photons slightly and cause the rotational oscillation of linearly polarized light. Dark matter Axion search with riNg Cavity Experiment (DANCE) searches for ALP dark matter by amplifying the rotational oscillation with a bow-tie ring cavity. Simultaneous resonance of linear polarizations is necessary to amplify both the carrier field and the ALP signal, and to achieve the design sensitivity. The sensitivity of the current prototype experiment DANCE Act-1 is less than expectation by around three orders of magnitude due to the resonant frequency difference between s- and p-polarization in the bow-tie ring cavity. In order to tune the resonant frequency difference, the method of introducing an auxiliary cavity was proposed. We designed an auxiliary cavity that can cancel out the resonant frequency difference and realize simultaneous resonance, considering optical loss. We also confirmed that the sensitivity of DANCE Act-1 with the auxiliary cavity can reach the original sensitivity.

physics.ins-det

Improving force sensitivity by amplitude measurement of light reflected from a detuned optomechanical cavity

The measurement of weak continuous forces exerted on a mechanical oscillator is a fundamental problem in various physical experiments. It is fundamentally impeded by quantum back-action from the meter used to sense the displacement of the oscillator. In the context of interferometric displacement measurements, we here propose and demonstrate the working principle of a scheme for coherent back-action cancellation. By measuring the amplitude quadrature of the light reflected from a detuned optomechanical cavity inside which a stiff optical spring is generated, back-action can be cancelled in a narrow band of frequencies. This method provides a simple way to improve the sensitivity in experiments limited by quantum back-action without injection of squeezed light or stable homodyne readout.

quant-ph

Dark matter Axion search with riNg Cavity Experiment DANCE: Development of control system for long-term measurement

Axion-like particles (ALPs) are pseudo-scalar particles that are candidates for ultralight dark matter. ALPs interact with photons slightly and cause the rotational oscillation of linear polarization. DANCE searches for ALP dark matter by enhancing the rotational oscillation in a bow-tie ring cavity. The signal to noise ratio of DANCE can be improved by long-term observation, and we are planning a year-long observation for the final DANCE. In this document, I will report on the control systems of the ring cavity we developed for the future long-term observation.

physics.ins-det

Dark matter Axion search with riNg Cavity Experiment DANCE: Current sensitivity

Dark matter Axion search with riNg Cavity Experiment (DANCE) was proposed. To search for axion-like particles, we aim to detect the rotation and oscillation of optical linear polarization caused by axion-photon coupling with a bow-tie cavity. DANCE can improve the sensitivity to axion-photon coupling constant $g_{a γ}$ for axion mass $m_a < 10^{-10} \, \rm{eV}$ by several orders of magnitude compared to the best upper limits at present. A prototype experiment DANCE Act-1 is in progress to demonstrate the feasibility of the method and to investigate technical noises. We assembled the optics, evaluated the performance of the cavity, and estimated the current sensitivity. If we observe for a year, we can reach $g_{a γ} \simeq 9 \times 10^{-7} \, \rm{GeV^{-1}}$ at $m_a \simeq 10^{-13} \, \rm{eV}$. The current sensitivity was believed to be limited by laser intensity noise at low frequencies and by mechanical vibration at high frequencies.

hep-ph

Improvement of the target sensitivity in DECIGO by optimizing its parameters for quantum noise including the effect of diffraction loss

DECIGO is the future Japanese gravitational wave detector in outer space. We previously set the default design parameters to provide a good target sensitivity to detect the primordial gravitational waves (GWs). However, the updated upper limit of the primordial GWs by the Planck observations motivated us for further optimization of the target sensitivity. Previously, we had not considered optical diffraction loss due to the very long cavity length. In this paper, we optimize various DECIGO parameters by maximizing the signal-to-noise ratio (SNR), for the primordial GWs to quantum noise including the effects of diffraction loss. We evaluated the power spectrum density for one cluster in DECIGO utilizing the quantum noise of one differential Fabry-Perot interferometer. Then we calculated the SNR by correlating two clusters in the same position. We performed the optimization for two cases: the constant mirror-thickness case and the constant mirror-mass case. As a result, we obtained the SNR dependence on the mirror radius, which also determines various DECIGO parameters. This result is the first step toward optimizing the DECIGO design by considering the practical constraints on the mirror dimension and implementing other noise sources.

gr-qc

Optimization of quantum noise by completing the square of multiple interferometer outputs in quantum locking for gravitational wave detectors

The quantum locking technique, which uses additional short low-loss sub-cavities, is effective in reducing quantum noise in space gravitational wave antenna DECIGO. However, the quantum noise of the main interferometer depends on the control systems in the sub-cavities. Here we demonstrate a new method to optimize the quantum noise independently of the feedback gain by completing the square in the quantum locking system. We successfully demonstrate in simulations that this method is effective in optimizing the homodyne angle to the best quantum-noise-limited sensitivity.

gr-qc