Searcharxiv⌕ Search

arXiv subjects

Masanori Fujiwara

Publications and source records attributed to Masanori Fujiwara.

6 recordsLinked to original sources

Enhanced Temperature Sensitivity in Ensemble NV Centers through Improved Optically Detected Magnetic Resonance Spectral Modeling

Nitrogen-vacancy (NV) center ensembles provide a powerful platform for high-precision temperature sensing, with ongoing efforts to further enhance their measurement performance. In ensemble NV optically detected magnetic resonance (ODMR) spectra, commonly used Lorentzian and Voigt fitting models fail to accurately describe the spectral shape near the resonance frequency, leading to degraded precision in resonance-frequency determination and, consequently, temperature estimation. In this work, we analytically establish a new fitting method, termed dip-peak fitting, for extracting the resonance frequency from ensemble cw-ODMR spectra. Starting from a physical model that describes ensemble cw-ODMR spectra as a convolution of single-NV responses with distributed zero-field splitting and strain, we show that the spectral feature near resonance can be accurately approximated by a single Lorentzian function with a background term. The proposed fitting model reproduces the cw-ODMR spectrum around resonance more faithfully than conventional approaches, enabling faster and more accurate resonance-frequency determination under weaker microwave excitation. Experiments using fluorescent nanodiamond ensembles confirm the robustness and applicability of this method for high-precision temperature sensing.

physics.ins-det↗

All-optical nanoscale thermometry based on silicon-vacancy centers in detonation nanodiamonds

Silicon-vacancy (SiV) centers in diamond are a promising candidate for all-optical nanoscale high-sensitivity thermometry because they have sufficient sensitivity to reach the subkelvin precision required for application to biosystems. It is expected that nanodiamonds with SiV centers can be injected into cells to measure the nanoscale local temperatures of biosystems such as organelles. However, the smallest particle size used to demonstrate thermometry using SiV centers is a few hundred nanometers. We recently developed SiV-center-containing nanodiamonds via a detonation process that is suitable for large-scale production. Here, we investigate the spectral response of SiV-center-containing detonation nanodiamonds (SiV-DNDs) to temperature. We used air-oxidized and polyglycerol-coated SiV-DNDs with a mean particle size of around 20 nm, which is the smallest size used to demonstrate thermometry using color centers in nanodiamond. We found that the zero-phonon line for SiV-DND is linearly red-shifted with increasing temperature in the range of 22.0 to 40.5 $^\circ C$. The peak sensitivity to temperature was 0.011 $\pm$ 0.002 nm/K, which agrees with the reported high sensitivity of SiV centers in bulk diamond. A temperature sensitivity analysis revealed that SiV-DND thermometry can achieve subkelvin precision. All-optical SiV-DND thermometry will be important for investigating nanosystems such as organelles in living cells.

cond-mat.mtrl-sci↗

Experimental and theoretical analysis of noise strength and environmental correlation time for ensembles of nitrogen-vacancy centers in diamond

We experimentally and theoretically investigate the Hahn echo decay curve for nitrogen vacancy centers in diamond with different spin concentrations. The Hahn echo results show a non-exponential decay for low spin concentrations, while an exponential decay is dominant for high spin concentrations. By fitting the decay curve with a theoretical model, we show that both the amplitude and correlation time of the environmental noise have a clear dependence on the spin concentration. These results are essential for optimizing the NV center concentration in high-performance quantum devices, particularly quantum sensors.

quant-ph↗

Room Temperature Electrically Detected Nuclear Spin Coherence of NV Centers in Diamond

We demonstrate electrical detection of the $^{14}$N nuclear spin coherence of NV centers at room temperature. Nuclear spins are candidates for quantum memories in quantum-information devices and quantum sensors, and hence the electrical detection of nuclear spin coherence is essential to develop and integrate such quantum devices. In the present study, we used a pulsed electrically detected electron-nuclear double resonance technique to measure the Rabi oscillations and coherence time ($T_2$) of $^{14}$N nuclear spins in NV centers at room temperature. We observed $T_2 \approx$ 0.9 ms at room temperature. Our results will pave the way for the development of novel electron- and nuclear-spin-based diamond quantum devices.

cond-mat.mes-hall↗

Extension of the Coherence Time by Generating MW Dressed States in a Single NV Centre in Diamond

Nitrogen-vacancy (NV) centres in diamond hold promise in quantum sensing applications. A major interest in them is an enhancement of their sensitivity by the extension of the coherence time ($T_2$). In this report, we experimentally generated more than four dressed states in a single NV centre in diamond based on Autler-Townes splitting (ATS). We also observed the extension of the coherence time to $T_2 \sim$ 1.5 ms which is more than two orders of magnitude longer than that of the undressed states. As an example of a quantum application using these results we propose a protocol of quantum sensing, which shows more than an order of magnitude enhancement in the sensitivity.

quant-ph↗

Optimization temperature sensitivity using the optically detected magnetic resonance spectrum of a nitrogen-vacancy center ensemble

Temperature sensing with nitrogen vacancy (NV) centers using quantum techniques is very promising and further development is expected. Recently, the optically detected magnetic resonance (ODMR) spectrum of a high-density ensemble of the NV centers was reproduced with noise parameters [inhomogeneous magnetic field, inhomogeneous strain (electric field) distribution, and homogeneous broadening] of the NV center ensemble. In this study, we use ODMR to estimate the noise parameters of the NV centers in several diamonds. These parameters strongly depend on the spin concentration. This knowledge is then applied to theoretically predict the temperature sensitivity. Using the diffraction-limited volume of 0.1 micron^3, which is the typical limit in confocal microscopy, the optimal sensitivity is estimated to be around 0.76 mK/Hz^(1/2) with an NV center concentration of 5.0e10^17/cm^3. This sensitivity is much higher than previously reported sensitivities, demonstrating the excellent potential of temperature sensing with NV centers.

quant-ph↗