SearcharxivSearch

arXiv subjects

Masao Takamoto

Publications and source records attributed to Masao Takamoto.

15 recordsLinked to original sources

Transportable Optical Lattice Clocks and General Relativity

Optical lattice clocks (OLCs) enable us to measure time and frequency with a fractional uncertainty at $10^{-18}$ level, which is 2 orders of magnitude better than Cs clocks. In this article, after briefly reviewing OLCs and the history of testing the fundamental principles of general relativity, we report our experiments of measuring the gravitational redshift between RIKEN and The University of Tokyo, and at Tokyo Skytree using transportable OLCs. We also discuss a couple of future applications of OLCs, such as detecting gravitational waves in space and relativistic geodesy. The possibility of testing second-order parametrized post-Newtonian potential around the Earth is also mentioned.

gr-qc

International comparison of optical frequencies with transportable optical lattice clocks

Optical clocks have improved their frequency stability and estimated accuracy by more than two orders of magnitude over the best caesium microwave clocks that realise the SI second. Accordingly, an optical redefinition of the second has been widely discussed, prompting a need for the consistency of optical clocks to be verified worldwide. While satellite frequency links are sufficient to compare microwave clocks, a suitable method for comparing high-performance optical clocks over intercontinental distances is missing. Furthermore, remote comparisons over frequency links face fractional uncertainties of a few $10^{-18}$ due to imprecise knowledge of each clock's relativistic redshift, which stems from uncertainty in the geopotential determined at each distant location. Here, we report a landmark campaign towards the era of optical clocks, where, for the first time, state-of-the-art transportable optical clocks from Japan and Europe are brought together to demonstrate international comparisons that require neither a high-performance frequency link nor information on the geopotential difference between remote sites. Conversely, the reproducibility of the clocks after being transported between countries was sufficient to determine geopotential height offsets at the level of 4 cm. Our campaign paves the way for redefining the SI second and has a significant impact on various applications, including tests of general relativity, geodetic sensing for geosciences, precise navigation, and future timing networks.

physics.atom-ph

Operational Magic Intensity for Sr Optical Lattice Clocks

We experimentally investigate the lattice-induced light shift by the electric-quadrupole ($E2$) and magnetic-dipole ($M1$) polarizabilities and the hyperpolarizability in Sr optical lattice clocks. Precise control of the axial as well as the radial motion of atoms in a one-dimensional lattice allows observing the $E2$-$M1$ polarizability difference. Measured polarizabilities determine an operational lattice depth to be $72(2) E_R$, where the total light shift cancels to the $10^{-19}$ level, over a lattice-intensity variation of about 30%. This operational trap depth and its allowable intensity range conveniently coincide with experimentally feasible operating conditions for Sr optical lattice clocks.

physics.atom-ph

Real-time geopotentiometry with synchronously linked optical lattice clocks

According to the Einstein's theory of relativity, the passage of time changes in a gravitational field. On earth, raising a clock by one centimetre increases its tick rate by 1.1 parts in 10$^{18}$, enabling optical clocks to perform precision geodesy. Here, we demonstrate geopotentiometry by determining the height difference of master and slave clocks separated by 15 km with uncertainty of 5 cm. The subharmonic of the master clock is delivered through a telecom fibre to phase-lock and synchronously interrogate the slave clock. This protocol rejects laser noise in the comparison of two clocks, which improves the stability of measuring the gravitational red shift. Such phase-coherently operated clocks facilitate proposals for linking clocks and interferometers. Over half a year, 11 measurements determine the fractional frequency difference between the two clocks to be $1,652.9(5.9)\times 10^{-18}$, or a height difference of 1,516(5) cm, consistent with an independent measurement by levelling and gravimetry. Our system is as a building block of an internet of clocks, consisting of a master and a number of slave clocks, which will provide "quantum benchmarks" that are height references with dynamic response.

physics.atom-ph

Frequency ratio of Yb and Sr clocks with $5 \times 10^{-17}$ uncertainty at 150 s averaging time

Transition frequencies of atoms and ions are among the most accurately accessible quantities in nature, playing important roles in pushing the frontiers of science by testing fundamental laws of physics, in addition to a wide range of applications such as satellite navigation systems. Atomic clocks based on optical transitions approach uncertainties of $10^{-18}$, where full frequency descriptions are far beyond the reach of the SI second. Frequency ratios of such super clocks, on the other hand, are not subject to this limitation. They can therefore verify consistency and overall accuracy for an ensemble of super clocks, an essential step towards a redefinition of the second. However, with the measurement stabilities so far reported for such frequency ratios, a confirmation to $1 \times 10^{-18}$ uncertainty would require an averaging time $τ$ of multiple months. Here we report a measurement of the frequency ratio of neutral ytterbium and strontium clocks with a much improved stability of $4 \times 10^{-16} (τ/s)^{-1/2}$. Enabled by the high stability of optical lattice clocks interrogating hundreds of atoms, this marks a 90-fold reduction in the required averaging time over a previous record-setting experiment that determined the ratio of Al+ and Hg+ single-ion clocks to an uncertainty of $5.2 \times 10^{-17}$. For the Yb/Sr ratio, we find R = 1.207 507 039 343 337 749(55), with a fractional uncertainty of $4.6 \times 10^{-17}$.

physics.atom-ph

Frequency ratios of Sr, Yb and Hg based optical lattice clocks and their applications

This article describes the recent progress of optical lattice clocks with neutral strontium ($^{87}$Sr), ytterbium ($^{171}$Yb) and mercury ($^{199}$Hg) atoms. In particular, we present frequency comparison between the clocks locally via an optical frequency comb and between two Sr clocks at remote sites using a phase-stabilized fibre link. We first review cryogenic Sr optical lattice clocks that reduce the room-temperature blackbody radiation shift by two orders of magnitude and serve as a reference in the following clock comparisons. Similar physical properties of Sr and Yb atoms, such as transition wavelengths and vapour pressure, have allowed our development of a compatible clock for both species. A cryogenic Yb clock is evaluated by referencing a Sr clock. We also report on a Hg clock, which shows one order of magnitude less sensitivity to blackbody radiation, while its large nuclear charge makes the clock sensitive to the variation of fine-structure constant. Connecting all three types of clocks by an optical frequency comb, the ratios of the clock frequencies are determined with uncertainties smaller than possible through absolute frequency measurements. Finally, we describe a synchronous frequency comparison between two Sr-based remote clocks over a distance of 15 km between RIKEN and the University of Tokyo, as a step towards relativistic geodesy.

physics.atom-ph

Frequency Ratio of ${}^{199}$Hg and ${}^{87}$Sr Optical Lattice Clocks beyond the SI Limit

We report on a frequency ratio measurement of a ${}^{199}$Hg-based optical lattice clock referencing a ${}^{87}$Sr-based clock. Evaluations of lattice light shift, including atomic-motion-dependent shift, enable us to achieve a total systematic uncertainty of $7.2 \times 10^{-17}$ for the Hg clock. The frequency ratio is measured to be $ν_{\rm Hg}/ν_{\rm Sr}=2.629\, 314\, 209\, 898\, 909\, 60(22)$ with a fractional uncertainty of $8.4 \times 10^{-17}$, which is smaller than the uncertainty of the realization of the SI second, i.e., the SI limit.

physics.atom-ph

Cryogenic optical lattice clocks with a relative frequency difference of $1\times 10^{-18}$

Time and frequency are the most accurately measurable quantities, providing foundations for science and modern technologies. The accuracy relies on the SI (Systéme International) second that refers to Cs microwave clocks with fractional uncertainties at $10^{-16}$. Recent revolutionary progress of optical clocks aims to achieve $1\times 10^{-18}$ uncertainty, which however has been hindered by long averaging-times or by systematic uncertainties. Here, we demonstrate optical lattice clocks with $^{87}$Sr atoms interrogated in a cryogenic environment to address the blackbody radiation-induced frequency-shift, which remains the primary source of clocks' uncertainties and has initiated vigorous theoretical and experimental investigations. The quantum-limited stability for $N \sim 1,000$ atoms allows investigation of the uncertainties at $2\times 10^{-18}$ in two hours of clock operation. After 11 measurements performed over a month, the two cryo-clocks agree to within $(-1.1\pm 1.6)\times 10^{-18}$. Besides its contribution to fundamental science and the redefinition of the SI second, such a speedy comparison of accurate clocks provides a means for relativistic geodesy.

physics.atom-ph

Direct Comparison of Distant Optical Lattice Clocks at the $10^{-16}$ Uncertainty

Fiber-based remote comparison of $^{87}$Sr lattice clocks in 24 km distant laboratories is demonstrated. The instability of the comparison reaches $5\times10^{-16}$ over an averaging time of 1000 s, which is two orders of magnitude shorter than that of conventional satellite links and is limited by the instabilities of the optical clocks. By correcting the systematic shifts that are predominated by the differential gravitational redshift, the residual fractional difference is found to be $(1.0\pm7.3)\times10^{-16}$, confirming the coincidence between the two clocks. The accurate and speedy comparison of distant optical clocks paves the way for a future optical redefinition of the second.

physics.atom-ph

Coherence of Spin-Polarized Fermions Interacting with a Clock Laser in a Stark-Shift-Free Optical Lattice

We investigated the coherence of spin-polarized ^{87}Sr atoms trapped in a light-shift-free one-dimensional optical lattice during their interaction with a clock laser on the ^1S_0-^3P_0 transition. Collapses and revivals appeared for more than 50 Rabi cycles, attributed to the thermal distribution of discrete vibrational states in the lattice potential. The population oscillation in the clock states lasted more than 1s, demonstrating high immunity from decoherence. This long atomic coherence suggests the feasibility of Pauli blocking of collisions in optical clock excitation.

physics.atom-ph

Magic-wave-induced $^1S_0-^3P_0$ transition in even isotopes of alkaline-earth-like atoms

The circular polarized laser beam of the ``magic'' wavelength may be used for mixing the $^3P_1$ state into the long-living metastable state $^3P_0$, thus enabling the strictly forbidden $^1S_0$$-$$^3P_0$ ''clock'' transition in even isotopes of alkaline-earth-like atoms, without change of the transition frequency. In odd isotopes the laser beam may adjust to an optimum value the line width of the "clock" transition, originally enabled by the hyperfine mixing. We present a detailed analysis of various factors influencing resolution and uncertainty for an optical frequency standard based on atoms exposed simultaneously to the lattice standing wave and an additional "state-mixing" wave, including estimations of the "magic" wavelengths, Rabi frequencies for the ''clock'' and state-mixing transitions, ac Stark shifts for the ground and metastable states of divalent atoms.

physics.atom-ph

Improved frequency measurement of a one-dimensional optical lattice clock with a spin-polarized fermionic $^{87}$Sr isotope

We demonstrate a one-dimensional optical lattice clock with a spin-polarized fermionic isotope designed to realize a collision-shift-free atomic clock with neutral atom ensembles. To reduce systematic uncertainties, we developed both Zeeman shift and vector light-shift cancellation techniques. By introducing both an H-maser and a Global Positioning System (GPS) carrier phase link, the absolute frequency of the $^1S_0(F=9/2) - {}^3P_0(F=9/2)$ clock transition of the $^{87}$Sr optical lattice clock is determined as 429,228,004,229,875(4) Hz, where the uncertainty is mainly limited by that of the frequency link. The result indicates that the Sr lattice clock will play an important role in the scope of the redefinition of the ``second'' by optical frequency standards.

physics.atom-ph

Wave-Function Reconstruction for the Determination of the Scattering Length of Sr

We have investigated the photoassociation (PA) spectra of ultracold $^{88}$Sr atoms near the $5s^2 ^1S_0+5s5p ^1P_1$ atomic asymptote. The intensity modulation of the PA lines was used to reconstruct the ground-state scattering wave function, whose nodal point inferred the s-wave scattering length of $a=1.1(2)$ nm. The observed PA resonances also determined a precise lifetime of the $^1P_1$ state to be 5.263(4) ns.

physics.atom-ph

Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap

An ultrastable optical clock based on neutral atoms trapped in an optical lattice is proposed. Complete control over the light shift is achieved by employing the $5s^2 {}^1S_0 \to 5s5p {}^3P_0$ transition of ${}^{87}{\rm Sr}$ atoms as a "clock transition". Calculations of ac multipole polarizabilities and dipole hyperpolarizabilities for the clock transition indicate that the contribution of the higher-order light shifts can be reduced to less than 1 mHz, allowing for a projected accuracy of better than $ 10^{-17}$.

physics.atom-ph

Spectroscopy of the $^1S_0-{}^3P_0$ Clock Transition of $^{87}$Sr in an Optical Lattice

We report on the spectroscopy of the $5s^2 {}^1S_0 (F=9/2) \to 5s5p {}^3P_0 (F=9/2)$ clock transition of ${}^{87}{\rm Sr}$ atoms (natural linewidth of 1 mHz) trapped in a one-dimensional optical lattice. Recoilless transitions with a linewidth of 0.7 kHz as well as the vibrational structure of the lattice potential were observed. By investigating the wavelength dependence of the carrier linewidth, we determined the magic wavelength, where the light shift in the clock transition vanishes, to be $813.5\pm0.9$ nm.

physics.atom-ph