Searcharxiv⌕ Search

arXiv subjects

Masashi Hazumi

Publications and source records attributed to Masashi Hazumi.

At least 19 recordsLinked to original sources

Millimeter-Wavelength Constraints on Circular Polarization of the Cosmic Microwave Background at Arcminute Scales with the Simons Array

We present constraints on the cosmic microwave background (CMB) circular polarization anisotropy at arcminute angular scales, using dedicated measurements from the Simons Array taken with a quarter-wave plate and rotating half-wave plate. A detection of circular polarization in the CMB would probe a range of proposed generation mechanisms, from Standard Model astrophysics to physics beyond it. At an observing frequency of 90 GHz, we place constraints over the multipole range $300 \leq \ell \leq 2000$, corresponding to angular scales of 5.4-36 arcmin, in bands of width $Δ\ell = 100$, roughly tripling the highest multipole previously reached by a $V$-mode power spectrum measurement. Within this domain, we constrain the 95% confidence upper bound of $\ell (\ell+1) C_\ell^{VV} / (2π)$ to range from $\sim 22\,μ\mathrm{K}_\mathrm{CMB}^2$ at the $\ell = 350$ bandpower to $\sim 3.5 \times 10^3\,μ\mathrm{K}_\mathrm{CMB}^2$ at the $\ell = 1950$ bandpower. These limits are derived from $\sim$2.5 months of observations of each of two small regions of the sky located away from the Galactic plane, totaling $\sim$12 deg$^2$ of effective sky area. Because the methodology of this study marginalizes known foreground contamination, these bounds serve as robust, conservative limits on the true CMB circular polarization signal down to the sensitivity limits of the instrument. Additionally, we provide an experimental and analytical framework for implementing circular polarization observations on other telescopes by utilizing a quarter-wave plate and half-wave plate design.

astro-ph.CO↗

CHRONOS Science Program

Cryogenic sub-Hz cROss torsion-bar detector with quantum NOn-demolition Speed meter (CHRONOS) is a proposed cryogenic torsion-bar interferometer for precision measurements in the 0.1-10 Hz band. A Sagnac speed-meter readout, power and signal recycling, and balanced homodyne detection provide control of the optical response and quantum measurement correlations. This White Paper describes the science program, detector design, calibration, and staged experimental development. The reference sensitivity uses a multi-input quantum model, including rear-mirror vacuum fields and measurement-back-action correlations, combined with classical noise. Two operating points are optimized for complementary power-law-integrated sensitivity objectives. Gravitational-wave forecasts use this common noise budget and state their source and observing assumptions. The program includes intermediate-mass black-hole binaries, stochastic backgrounds, quantum measurement, and terrestrial gravity perturbations. Dark-matter applications are discussed as response and feasibility studies. A differential gravitational calibrator provides a proposed Yukawa-gravity test whose systematic floor is improved by subtracting auxiliary harmonics. These are conditional projections: experimental reach requires validation of the noise, transfer functions, environmental backgrounds, and systematic uncertainties described here.

astro-ph.IM↗

Development and characterization of a millimeter-wave circular polarization observation method using a quarter-wave plate with Simons Array

We have developed and demonstrated a method for measuring circular polarization at 90 GHz by combining a quarter-wave plate (QWP) and a continuously rotating half-wave plate (HWP). While many bolometric experiments at millimeter wavelengths focus on measuring linear polarization, observations of circular polarization in millimeter waves may open a new window into astrophysics and cosmology. We present a novel approach to circular-polarization search using linear-polarization-sensitive detectors by incorporating a QWP in the optics. The Simons Array was originally designed for precise linear polarization measurements, and we subsequently installed a QWP in front of the receiver targeting 90 GHz. The QWP converts incident circular polarization to linear polarization, allowing detection with our detectors. Laboratory measurements demonstrate a QWP conversion efficiency of 99.0%. We apply our method to observations of unpolarized and linearly polarized bright sources, Jupiter and Tau A. Using these observations, we establish the calibration and characterize the instrumental leakages relevant to circular polarization measurements. The measured polarization efficiency adopted for Stokes $V$ is $46\pm2$%, and the measured U-to-V leakage is $-11.7\pm5.1$%. We measure a circular polarization fraction of $V/I=0.78\pm0.42$% for Tau A, showing no significant detection and providing a consistency check of the calibration and systematic-uncertainty treatment. These results establish the instrument response model and calibration parameters used for the companion circular-polarization source search.

astro-ph.IM↗

Quantum noise and torque correlations in a torsion-bar Sagnac speed meter

Quantum fluctuations entering through weakly transmitting mirrors can limit a torsion-bar Sagnac speed meter for low-frequency gravitational-wave detection, even when its optical layout suppresses radiation-pressure back action. We show that, in the Cryogenic sub-Hz cROss torsion bar detector with quantum NOn-demolition Speed meter (CHRONOS), vacuum fields entering from behind the end and middle test masses can dominate the low-frequency quantum noise despite cancellation of the torques on opposite ends of each bar. For a reference configuration with mirror power transmissions of only $10^{-7}$, these fields contribute $89.7\%$ of the total quantum-noise power spectral density at 0.1 Hz. Omitting them would underestimate the amplitude spectral density by a factor of 3.11. Our input-output model connects the correlations produced by successive optical interactions to the forces on each bar and the measured signal. This connection shows why strong torque cancellation does not, by itself, ensure a corresponding improvement in detector sensitivity. Replacing mirror transmission with absorption at fixed reflectivity leaves the excess quantum noise essentially unchanged for the two operating points studied. The predicted signal response and quantum noise agree with independent FINESSE 3 calculations as recycling detuning and homodyne angle are varied. These results establish rear vacuum fields as a limiting noise source in this torsion-bar speed meter and provide quantitative requirements for its mirror and readout design.

gr-qc↗

Entanglement-enhanced AC magnetometry in the presence of Markovian noises

Entanglement is a resource to improve the sensitivity of quantum sensors. In an ideal case, using an entangled state as a probe to detect target fields, we can beat the standard quantum limit by which all classical sensors are bounded. However, since entanglement is fragile against decoherence, it is unclear whether entanglement-enhanced metrology is useful in a noisy environment. Its benefit is indeed limited when estimating the amplitude of DC magnetic fields under the effect of parallel Markovian decoherence, where the noise operator is parallel to the target field. In this paper, on the contrary, we show an advantage to using an entanglement over the classical strategy under the effect of parallel Markovian decoherence when we try to detect AC magnetic fields. We consider a scenario to induce a Rabi oscillation of the qubits with the target AC magnetic fields. Although we can, in principle, estimate the amplitude of the AC magnetic fields from the Rabi oscillation, the signal becomes weak if the qubit frequency is significantly detuned from the frequency of the AC magnetic field. We show that, by using the GHZ states, we can significantly enhance the signal of the detuned Rabi oscillation even under the effect of parallel Markovian decoherence. Our method is based on the fact that the interaction time between the GHZ states and AC magnetic fields scales as $1/L$ to mitigate the decoherence effect where $L$ is the number of qubits, which contributes to improving the bandwidth of the detectable frequencies of the AC magnetic fields. Our results open up the way for new applications of entanglement-enhanced AC magnetometry.

quant-ph↗

Constraints on the polarization angle oscillations of the Crab Nebula with the Simons Array and its applications to the search for axion-like particles

We present a search for polarization oscillation of the Crab Nebula, also known as Tau A, at millimeter wavelengths using observations with the Simons Array, the successor experiment to POLARBEAR. We follow up on previous work by POLARBEAR using 90 GHz band data of the 2023 observing season of the Simons Array to evaluate the variability of Tau A's polarization angle. Tau A is widely used as a polarization angle calibration source in millimeter-wave astronomy, and thus it is necessary to validate the stability. Additionally, an interesting application of the time-resolved polarimetry of Tau A is to search for axion-like particles (ALPs). We do not detect a global signal across the frequencies considered in this analysis and place a median 95% upper bound of polarization oscillation amplitude $A<0.12^{\circ}$ over oscillation frequencies from 3.39 year$^{-1}$ to 1.50 day$^{-1}$. This constrains the ALP-photon coupling at a median 95% upper bound of $g_{aγγ}< 3.84\times 10^{-12}\times\left(m_a/10^{-21}\,\mathrm{eV}\right)$ in the mass range from $4.4\times10^{-22}$ to $7.2\times10^{-20}$ eV, assuming the ALP constitutes all of dark matter, its field is a stochastic Gaussian field, and it is the sole source of Tau A's polarization angle oscillation. Additionally, we do not detect signal at the frequencies where 2.5$σ$ hints were previously reported by POLARBEAR, but we do not exclude these signals at the 95% confidence level.

astro-ph.CO↗

Hybrid-spin decoupling for noise-resilient DC quantum sensing

The excellent sensitivities of quantum sensors are a double-edged sword: minuscule quantities can be observed, but any undesired signal acts as noise. This is challenging when detecting quantities that are obscured by such noise. Decoupling sequences improve coherence times and hence sensitivities, though only AC signals in narrow frequency bands are distinguishable. Alternatively, comagnetometers operate gaseous spin mixtures at high temperatures in the self-compensating regime to counteract slowly varying noise. These are applied with great success in various exotic spin-interaction searches. Here, we propose a method that decouples specific DC fields from DC and AC magnetic noise. It requires any spin cluster where the effect on each individual spin is different for the target field and local magnetic fields, which allows for a different approach compared to comagnetometers. The presented method has several key advantages, including an orders-of-magnitude increase in noise frequencies to which we are resistant. We explore electron-spin nuclear-spin pairs in nitrogen-vacancy centres in diamond, with a focus on their merit for light dark-matter searches. Other applications include gradient sensing, quantum memory, and gyroscopes.

quant-ph↗

Quantum measurement systems and applications to particle physics and cosmology

There are new detector proposals and R&D that utilize quantum enhancements not previously adopted. Examples include superconducting quantum sensors, atom interferometry, and quantum spin sensors. They are mainly motivated by industrial applications toward quantum computing, secure quantum communication systems, and high-sensitivity sensors. Given the excellent potential of the new quantum measurement systems, there are also new proposals to apply them in particle physics and cosmology. In this review, I survey currently available and emerging quantum technologies and their applications. I then discuss future directions and new proposals for particle physics and cosmology.

physics.ins-det↗

Nuclear Spin Metrology with Nitrogen Vacancy Center in Diamond for Axion Dark Matter Detection

We present a method to directly detect the axion dark matter using nitrogen vacancy centers in diamonds. In particular, we use metrology leveraging the nuclear spin of nitrogen to detect axion-nucleus couplings. This is achieved through protocols designed for dark matter searches, which introduce a novel approach of quantum sensing techniques based on the nitrogen vacancy center. Although the coupling strength of the magnetic fields with nuclear spins is three orders of magnitude smaller than that with electron spins for conventional magnetometry, the axion interaction strength with nuclear spins is the same order of magnitude as that with electron spins. Furthermore, we can take advantage of the long coherence time by using the nuclear spins for the axion dark matter detection. We show that our method is sensitive to a broad frequency range $\lesssim 100\,\mathrm{Hz}$ corresponding to the axion mass $m_a \lesssim 4\times 10^{-13}\,\mathrm{eV}$. We present the detection limit of our method for both the axion-neutron and the axion-proton couplings and discuss its significance in comparison with other proposed ideas.

hep-ph↗

Light Dark Matter Search with Nitrogen-Vacancy Centers in Diamonds

We propose new ideas to directly search for light dark matter, such as the axion or the dark photon, by using magnetometry with nitrogen-vacancy centers in diamonds. If the dark matter couples to the electron spin, it affects the evolution of the Bloch vectors consisting of the spin triplet states, which may be detected through several magnetometry techniques. We give several concrete examples with the use of dc and ac magnetometry and estimate the sensitivity on dark matter couplings.

hep-ph↗

A measurement of atmospheric circular polarization with POLARBEAR

At millimeter wavelengths, the atmospheric emission is circularly polarized owing to the Zeeman splitting of molecular oxygen by the Earth's magnetic field. We report a measurement of the signal in the 150 GHz band using 3 years of observational data with the \textsc{Polarbear} project. Non-idealities of a continuously rotating half-wave plate (HWP) partially convert circularly polarized light to linearly polarized light. While \textsc{Polarbear} detectors are sensitive to linear polarization, this effect makes them sensitive to circular polarization. Although this was not the intended use, we utilized this conversion to measure circular polarization. We reconstruct the azimuthal gradient of the circular polarization signal and measure its dependency from the scanning direction and the detector bandpass. We compare the signal with a simulation based on atmospheric emission theory, the detector bandpass, and the HWP leakage spectrum model. We find the ratio of the observed azimuthal slope to the simulated slope is $0.92 \pm 0.01\rm{(stat)} \pm 0.07\rm{(sys)}$. This ratio corresponds to a brightness temperature of $3.8\,\mathrm{m K}$ at the effective band center of $121.8\,\mathrm{GHz}$ and bandwidth of $3.5\,\mathrm{GHz}$ estimated from representative detector bandpass and the spectrum of Zeeman emission. This result validates our understanding of the instrument and reinforces the feasibility of measuring the circular polarization using the imperfection of continuously rotating HWP. Continuously rotating HWP is popular in ongoing and future cosmic microwave background experiments to modulate the polarized signal. This work shows a method for signal extraction and leakage subtraction that can help measuring circular polarization in such experiments.

astro-ph.IM↗

The Simons Observatory: Design, Integration, and Current Status of Small Aperture Telescopes

The Simons Observatory (SO) is a cosmic microwave background (CMB) survey experiment located in the Atacama Desert in Chile at an elevation of 5200 meters, nominally consisting of an array of three 0.42-meter small aperture telescopes (SATs) and one 6-meter large aperture telescope (LAT). SO will make accurate measurements of the CMB temperature and polarization spanning six frequency bands ranging from 27 to 280 GHz, fielding a total of $\sim$68,000 detectors covering angular scales between one arcminute to tens of degrees. In this paper, we focus on the SATs, which are tailored to search for primordial gravitational waves, with the primary science goal of measuring the primordial tensor-to-scalar ratio \textit{r} at a target level of $σ(r) \approx 0.003$. We discuss the design drivers, scientific impact, and current deployment status of the three SATs, which are scheduled to start taking data in the coming year. The SATs aim to map 10\% of the sky at a 2 $μ$K-arcmin noise level observing at mid-frequencies (93/145 GHz), with additional ultra-high-frequency (225/280 GHz) and low-frequency (27/39 GHz) targets to yield galactic foreground-subtracted measurements.

astro-ph.IM↗

Zero Casimir Force in Axion Electrodynamics and the Search for a New Force

We point out that there is a stable configuration of metal plates where the Casimir force is vanishing in axion electrodynamics. We consider a concrete setup involving Weyl semimetals, which hosts an axion-like effect on the electromagnetism, towards the measurement of the axionic effect on the Casimir force. Our setup realizes zero Casimir force between metals and may be useful for the search for new force mediated by light particles at the micrometer scale.

hep-ph↗

Exploration of the polarization angle variability of the Crab Nebula with POLARBEAR and its application to the search for axion-like particles

The Crab Nebula, also known as Tau A, is a polarized astronomical source at millimeter wavelengths. It has been used as a stable light source for polarization angle calibration in millimeter-wave astronomy. However, it is known that its intensity and polarization vary as a function of time at a variety of wavelengths. Thus, it is of interest to verify the stability of the millimeter-wave polarization. If detected, polarization variability may be used to better understand the dynamics of Tau~A, and for understanding the validity of Tau~A as a calibrator. One intriguing application of such observation is to use it for the search of axion-like particles (ALPs). Ultralight ALPs couple to photons through a Chern-Simons term, and induce a temporal oscillation in the polarization angle of linearly polarized sources. After assessing a number of systematic errors and testing for internal consistency, we evaluate the variability of the polarization angle of the Crab Nebula using 2015 and 2016 observations with the 150 GHz POLARBEAR instrument. We place a median 95% upper bound of polarization oscillation amplitude $A < 0.065^\circ$ over the oscillation frequencies from $0.75~\mathrm{year}^{-1}$ to $0.66~\mathrm{hour}^{-1}$. Assuming that no sources other than ALP are causing Tau A's polarization angle variation, that the ALP constitutes all the dark matter, and that the ALP field is a stochastic Gaussian field, this bound translates into a median 95% upper bound of ALP-photon coupling $g_{aγγ} < 2.16\times10^{-12}\,\mathrm{GeV}^{-1}\times(m_a/10^{-21} \mathrm{eV})$ in the mass range from $9.9\times10^{-23} \mathrm{eV}$ to $7.7\times10^{-19} \mathrm{eV}$. This demonstrates that this type of analysis using bright polarized sources is as competitive as those using the polarization of cosmic microwave background in constraining ALPs.

astro-ph.CO↗

Commissioning the CMB polarization telescope GroundBIRD with the full set of detectors

GroundBIRD is a ground-based cosmic microwave background (CMB) experiment for observing the polarization pattern imprinted on large angular scales ($\ell > 6$ ) from the Teide Observatory in Tenerife, Spain. Our primary scientific objective is a precise measurement of the optical depth $τ$ ($σ(τ) \sim 0.01$) to the reionization epoch of the Universe to cross-check systematic effects in the measurements made by previous experiments. GroundBIRD observes a wide sky area in the Northern Hemisphere ($\sim 40\%$ of the full sky) while continuously rotating the telescope at a high speed of up to 20 rotations per minute (rpm) to overcome the fluctuations of atmospheric radiation. We have adopted the NbTiN/Al hybrid microwave kinetic inductance detectors (MKIDs) as focal plane detectors. We observe two frequency bands centered at 145 GHz and 220 GHz. The 145 GHz band picks up the peak frequency of the CMB spectrum. The 220 GHz band helps accurate removal of the contamination of thermal emission from the Galactic interstellar dust. The MKID arrays (138 MKIDs for 145GHz and 23 MKIDs for 220GHz) were designed and optimized so as to minimize the contamination of the two-level-system noise and maximize the sensitivity. The MKID arrays were successfully installed in May 2023 after the performance verification tests were performed at a laboratory. GroundBIRD has been upgraded to use the full MKID arrays, and scientific observations are now underway. The telescope is automated, so that all observations are performed remotely. Initial validations, including polarization response tests and observations of Jupiter and the moon, have been completed successfully. We are now running scientific observations.

astro-ph.IM↗

Development of the Low Frequency Telescope focal plane detector arrays for LiteBIRD

LiteBIRD, a forthcoming JAXA mission, aims to accurately study the microwave sky within the 40-400 GHz frequency range divided into 15 distinct nominal bands. The primary objective is to constrain the CMB inflationary signal, specifically the primordial B-modes. LiteBIRD targets the CMB B-mode signal on large angular scales, where the primordial inflationary signal is expected to dominate, with the goal of reaching a tensor-to-scalar ratio sensitivity of $σ_r\sim0.001$. LiteBIRD frequency bands will be split among three telescopes, with some overlap between telescopes for better control of systematic effects. Here we report on the development status of the detector arrays for the Low Frequency Telescope (LFT), which spans the 34-161 GHz range, with 12 bands subdivided between four types of trichroic pixels consisting of lenslet-coupled sinuous antennas. The signal from the antenna is bandpass filtered and sensed by AlMn Transition-Edge Sensors (TES). We provide an update on the status of the design and development of LiteBIRD's LFT LF1 (40-60-78 GHz), LF2 (50-68-89 GHz) pixels. We discuss design choices motivated by LiteBIRD scientific goals. In particular we focus on the details of the optimization of the design parameters of the sinuous antenna, on-chip bandpass filters, cross-under and impedance transformers and all the RF components that define the LF1 and LF2 pixel detection chain. We present this work in the context of the technical challenges and physical constraints imposed by the finite size of the instrument.

astro-ph.IM↗

A Method of Measuring TES Complex ETF Response in Frequency-domain Multiplexed Readout by Single Sideband Power Modulation

The digital frequency domain multiplexing (DfMux) technique is widely used for astrophysical instruments with large detector arrays. Detailed detector characterization is required for instrument calibration and systematics control. We conduct the TES complex electrothermal-feedback (ETF) response measurement with the DfMux readout system as follows. By injecting a single sideband signal, we induce modulation in TES power dissipation over a frequency range encompassing the detector response. The modulated current signal induced by TES heating effect is measured, allowing for the ETF response characterization of the detector. With the injection of an upper sideband, the TES readout current shows both an upper and a lower sideband. We model the upper and lower sideband complex ETF response and verify the model by fitting to experimental data. The model not only can fit for certain physical parameters of the detector, such as loop gain, temperature sensitivity, current sensitivity, and time constant, but also enables us to estimate the systematic effect introduced by the multiplexed readout. The method is therefore useful for in-situ detector calibration and for estimating systematic effects during astronomical telescope observations, such as those performed by the upcoming LiteBIRD satellite.

astro-ph.IM↗

Testing multi-field inflation with LiteBIRD

We investigate expected constraints on the primordial tensor power spectrum from the future cosmic microwave background polarization experiment LiteBIRD as a test of multi-field inflation. We argue that the measurements of the tensor-to-scalar ratio and the tensor spectral index, in combination with the constraints on the scalar spectral index from the Planck observation, are useful in testing multi-field inflation models. We also discuss implications for multi-field inflationary model building.

astro-ph.CO↗