SearcharxivSearch

arXiv subjects

Masato Takahashi

Publications and source records attributed to Masato Takahashi.

5 recordsLinked to original sources

Letter Of Intent for a future $\mu^+ \to \mathrm{e}^+ \gamma$ experiment at the High Intensity Muon Beam facility at PSI

Searches for charged lepton flavor violation in the muon sector stand out among the most sensitive and clean probes for physics beyond the Standard Model. Currently, $\mu^+ \to \mathrm{e}^+ \gamma$ experiments provide the best constraints in this field for a wide range of models while, in the coming years, new experiments investigating the processes of $\mu^+ \to \mathrm{e}^+ \mathrm{e}^+ \mathrm{e}^-$ and $\mu \to \mathrm{e}$ conversion in the nuclear field are anticipated to reach comparable or higher sensitivities. The High-Intensity Muon Beam (HIMB) facility at PSI, which is expected to deliver muon beam intensities up to two orders of magnitude higher than the existing beam lines, offers a unique opportunity to significantly enhance the sensitivity of $\mu^+ \to \mathrm{e}^+ \gamma$ searches. The discovery potential could be substantially boosted and a sensitivity comparable to that of all the other projects could be reestablished, which is essential for discriminating among competing new-physics scenarios should an observation occur in any of the channels. In this document, we express our interest in developing a $\mu^+ \to \mathrm{e}^+ \gamma$ experimental program at HIMB, with the goal of improving, within the next decade, the sensitivity of the $\mu^+ \to \mathrm{e}^+ \gamma$ search by more than one order of magnitude relative to the expected final result of the current leading experiment, MEG II. This effort would ensure that PSI retains its leadership in this field.

hep-ex

Development of a high-rate capable DLC-RPC based on a current evacuation pattern

A Resistive Plate Chamber using Diamond-Like Carbon electrodes (DLC-RPC) has been developed as a background tagging detector in the MEG$~$II experiment. The DLC-RPC is planned to be installed in a high-intensity and low-momentum muon beam. This detector is required to have a detection efficiency above 90 % with four active gaps in the muon beam due to the limitation of the material budget. In such an environment, the high current flowing through the resistive electrodes causes a voltage drop, which reduces the performance of the DLC-RPC. This voltage drop can be suppressed by implementing a current evacuation pattern, though discharges are more likely to occur near the pattern. Therefore the pattern must be covered by a protection cover made of an insulator. In this study, electrode samples with a current evacuation pattern and different widths of protection cover (0.2 mm and 0.8 mm) have been produced, and their performance and stability were measured. The detection efficiency of a single-gap chamber for $\beta$-rays from a $^{90}$Sr source was measured to be up to approximately 60 % in both electrode samples. The target efficiency can be achieved even with a drop of 100 $-$ 150 V. On the other hand, after more than a dozen hours of operation, discharges suddenly occurred and the detector was prevented from further operation. These discharges created current paths on the spacing pillars. This serious problem must be investigated and solved in the future.

physics.ins-det

Radiation Hardness Studies of RPC Based on Diamond-Like Carbon Electrodes for MEG II Experiment

A novel type of resistive plate chamber, based on diamond-like carbon (DLC) electrodes is under development for background identification in the MEG II experiment. The DLC-RPC is required to have a radiation hardness to mass irradiation since it is planned to be placed in a high-intensity and low-momentum muon beam. In this study, the aging test using a high-intensity X-ray beam was conducted to evaluate the radiation hardness of the DLC-RPC. The accumulated charge due to X-ray irradiation reached about 54 C/cm$^2$, which is approximately half of the one-year irradiation dose expected in the MEG II experiment. As a result, the degradation of the gas gain was observed due to fluorine deposition and insulators formed on the DLC electrodes. In addition, discharges via spacers were also observed repeatedly and interrupted the DLC-RPC operation.

physics.ins-det

Prototype study of $0.1\%\,X_0$ and $\mathrm{MHz/cm^2}$ tolerant Resistive Plate Chamber with Diamond-Like Carbon electrodes

A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{μm}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use of thin films coated with DLC enables an ultra-low mass design of $< 0.1\%\,X_0$ with up to a four-layer configuration. At the same time, 42% MIP efficiency, and 180 ps timing resolution per layer were achieved in a measurement performed under a $1\,\mathrm{MHz/cm^2}$ non-MIP charged particle beam. In addition, we propose a further improved design for a $20\,\mathrm{cm}$-scale detector that can achieve 90% four-layer efficiency in an even higher $4\,\mathrm{MHz/cm^2}$ beam. In this paper, we describe the detector design, present the results of performance measurements, and characterize the rate capability of the DLC-based RPCs with a performance projection for an improved design.

physics.ins-det

Development of ultra-low mass and high-rate capable RPC based on Diamond-Like Carbon electrodes for MEG II experiment

A new type of resistive plate chamber with thin-film electrodes based on diamond-like carbon is under development for background identification in the MEG II experiment. Installed in a low-momentum and high-intensity muon beam, the detector is required to have extremely low mass and a high rate capability. A single-layer prototype detector with 2 cm $\times$ 2 cm size was constructed and evaluated to have a high rate capability of 1 MHz/cm$^2$ low-momentum muons. For a higher rate capability and scalability of the detector size, the electrodes to supply high voltage were segmented at a 1 cm pitch by implementing a conductive pattern on diamond-like carbon. Using the new electrodes, a four-layer prototype detector was constructed and evaluated to have a 46% detection efficiency with only a single layer active at a rate of $\cal O$(10 kHz). The result with the new electrodes is promising to achieve the required detection efficiency of 90% at a rate of 4 MHz/cm$^2$ with all the layers active.

physics.ins-det