Target Flow-Pressure Operating Range for Designing a Failing Fontan Cavopulmonary Support Device

Fontan operation as the current standard of care for the palliation of single ventricle defects results in significant late complications. Using a mechanical circulatory device for the right circulation to serve the function of the missing subpulmonary ventricle could potentially stabilize the failing Fontan circulation. This study aims to elucidate the hydraulic operating regions that should be targeted for designing cavopulmonary blood pumps. By integrating numerical analysis and available clinical information, the interaction of the cavopulmonary support via the IVC and full assist configurations with a wide range of simulated adult failing scenarios was investigated; with IVC and full assist corresponding to the inferior venous return or the entire venous return, respectively, being routed through the device. We identified the desired hydraulic operating regions for a cavopulmonary assist device by clustering all head pressures and corresponding pump flows that result in hemodynamic improvement for each simulated failing Fontan physiology. Results show that IVC support can produce beneficial hemodynamics in only a small fraction of failing Fontan scenarios. Cavopulmonary assist device could increase cardiac index by 35% and decrease the inferior vena cava pressure by 45% depending on the patient's pre-support hemodynamic state and surgical configuration of the cavopulmonary assist device (IVC or full support). The desired flow-pressure operating regions we identified can serve as the performance criteria for designing cavopulmonary assist devices as well as evaluating off-label use of commercially available left-side blood pumps for failing Fontan cavopulmonary support.

q-bio.QM

Risks and Benefits of Using a Commercially Available Ventricular Assist Device for Failing Fontan Cavopulmonary Support: A Modeling Investigation

Fontan patients often develop circulatory failure and are in desperate need of a therapeutic solution. A blood pump surgically placed in the cavopulmonary pathway can substitute the function of the absent sub-pulmonary ventricle by generating a mild pressure boost. However, there is currently no commercially available device designed for the cavopulmonary application; and the risks and benefits of implanting a ventricular assist device (VAD) originally designed for the left ventricular application on the right circulation of failing Fontan patients is not yet clear. Moreover, further research is needed to compare the hemodynamics between the two clinically-considered surgical configurations (Full Support and IVC Support) for cavopulmonary assist, with Full and IVC Support corresponding to the entire venous return or only the inferior venous return, respectively, being routed through the VAD. In this study, we used a numerical model of the failing Fontan physiology to evaluate the Fontan hemodynamic response to a left VAD during the IVC and Full supports. We observed that during the Full support the VAD improved the cardiac output while maintaining blood pressures within safe ranges, and lowered the IVC pressure to <15mmHg; however, we found a potential risk of lung damage at higher pump speeds due to the excessive pulmonary pressure elevation. IVC support the other hand, did not benefit the hemodynamics of the example failing Fontan patients, resulting in the superior vena cava pressure increasing to an unsafe level of >20 mmHg. The findings in this study may be helpful to surgeons for recognizing the risks of a cavopulmonary VAD and developing coherent clinical strategies for the implementation of cavopulmonary support.

q-bio.TO