SearcharxivSearch

arXiv subjects

Massimo Minuti

Publications and source records attributed to Massimo Minuti.

At least 19 recordsLinked to original sources

The enhanced X-ray Timing and Polarimetry mission -- eXTP for launch in 2030

In this paper we present the current status of the enhanced X-ray Timing and Polarimetry mission, which has been fully approved for launch in 2030. eXTP is a space science mission designed to study fundamental physics under extreme conditions of matter density, gravity, and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring the effects of quantum electro-dynamics, and understanding the dynamics of matter in strong-field gravity. In addition to investigating fundamental physics, the eXTP mission is poised to become a leading observatory for time-domain and multi-messenger astronomy in the 2030's, as well as providing observations of unprecedented quality on a variety of galactic and extragalactic objects. After briefly introducing the history and a summary of the scientific objectives of the eXTP mission, this paper presents a comprehensive overview of: 1) the cutting-edge technology, technical specifications, and anticipated performance of the mission's scientific instruments; 2) the full mission profile, encompassing spacecraft design, operational capabilities, and ground segment infrastructure.

astro-ph.HE

The Telescope Calibration of the Imaging X-ray Polarimetry Explorer

Fifty years after the very first sounding rocket measurement of cosmic X-ray polarization, the Imaging X-ray Polarimetry Explorer (IXPE) mission has effectively opened a new window into the X-ray sky. Prior to launch of IXPE, an extensive calibration campaign was carried out to fully characterize the response of this new type of instrument. Specifically, the polarization-sensitive detectors were intensively calibrated in Italy, where they were developed and built. The X-ray optics, which collect and focus X rays onto the detectors, were built and calibrated in the U.S. A key question was whether the telescope (optics + detectors) calibrations could be synthesized from the individual component calibrations, avoiding time consuming and costly end-to-end calibrations for a flight program with a fixed schedule. The data presented here are from a calibration of the flight spare telescope utilizing the flight spare detector and flight spare mirror assembly combined. These data show that the presence of the mirror module does not affect the polarization response of the detectors (within the required calibration accuracy) and that the angular resolution of the telescopes could be accurately determined. Thus, the original extensive stand-alone ground calibration data of all the flight detectors and all the flight optic can be utilized in full to derive the flight telescopes calibrations.

astro-ph.IM

Polarization properties of X-ray tubes used for Imaging X-ray Polarimetry Explorer calibration

In this work, we measured the polarization properties of the X-rays emitted from the X-ray tubes, which were used during the calibration of the instrument onboard Imaging X-ray Polarimetry Explorer (IXPE). X-ray tubes are used as a source of unpolarized X-rays to calibrate the response of the gas pixel detectors to unpolarized radiation. However, even though the characteristic fluorescent emission lines are unpolarized, continuum bremsstrahlung emission can be polarized based on the geometry of the accelerated electrons and emitted photons. Hence, characterizing the contribution of polarized X-rays from bremsstrahlung emission is of interest, also for future measurements. We find that when accelerated electrons are parallel to the emitted photons, the bremsstrahlung emission is unpolarized, and when they are perpendicular, the polarization increases with energy, as expected from the theoretical predictions. A comparison with the theoretical predictions is also shown.

astro-ph.IM

X-ray Polarimetry of the accreting pulsar 1A~0535+262 in the supercritical state with PolarLight

The X-ray pulsar 1A 0535+262 exhibited a giant outburst in 2020, offering us a unique opportunity for X-ray polarimetry of an accreting pulsar in the supercritical state. Measurement with PolarLight yielded a non-detection in 3-8 keV; the 99% upper limit of the polarization fraction (PF) is found to be 0.34 averaged over spin phases, or 0.51 based on the rotating vector model. No useful constraint can be placed with phase resolved polarimetry. These upper limits are lower than a previous theoretical prediction of 0.6-0.8, but consistent with those found in other accreting pulsars, like Her X-1, Cen X-3, 4U 1626-67, and GRO J1008-57, which were in the subcritical state, or at least not confidently in the supercritical state, during the polarization measurements. Our results suggest that the relatively low PF seen in accreting pulsars cannot be attributed to the source not being in the supercritical state, but could be a general feature.

astro-ph.HE

Calibration of the IXPE focal plane X-ray polarimeters to polarized radiation

IXPE (Imaging X-ray Polarimetry Explorer) is a NASA Small Explorer mission -- in partnership with the Italian Space Agency (ASI) -- dedicated to X-ray polarimetry in the 2--8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector (GPD), a gas detector that allows measuring the polarization degree by using the photoelectric effect. A wide and accurate ground calibration was carried out on the IXPE Detector Units (DUs) at INAF-IAPS, in Italy, where a dedicated facility was set-up at this aim. In this paper, we present the results obtained from this calibration campaign to study the IXPE focal plane detector response to polarized radiation. In particular, we report on the modulation factor, which is the main parameter to estimate the sensitivity of a polarimeter.

astro-ph.IM

A significant detection of X-ray Polarization in Sco X-1 with PolarLight and constraints on the corona geometry

We report the detection of X-ray polarization in the neutron star low mass X-ray binary Scorpius (Sco) X-1 with PolarLight. The result is energy dependent, with a non-detection in 3-4 keV but a 4$\sigma$ detection in 4-8 keV; it is also flux dependent in the 4-8 keV band, with a non-detection when the source displays low fluxes but a 5$\sigma$ detection during high fluxes, in which case we obtain a polarization fraction of $0.043 \pm 0.008$ and a polarization angle of $52.6^\circ \pm 5.4^\circ$. This confirms a previous marginal detection with OSO-8 in the 1970s, and marks Sco X-1 the second astrophysical source with a significant polarization measurement in the keV band. The measured polarization angle is in line with the jet orientation of the source on the sky plane ($54^\circ$), which is supposedly the symmetric axis of the system. Combining previous spectral analysis, our measurements suggest that an optically thin corona is located in the transition layer under the highest accretion rates, and disfavor the extended accretion disk corona model.

astro-ph.HE

The Imaging X-Ray Polarimetry Explorer (IXPE): Pre-Launch

Scheduled to launch in late 2021, the Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer Mission in collaboration with the Italian Space Agency (ASI). The mission will open a new window of investigation - imaging X-ray polarimetry. The observatory features 3 identical telescopes each consisting of a mirror module assembly with a polarization-sensitive imaging X-ray detector at the focus. A coilable boom, deployed on orbit, provides the necessary 4-m focal length. The observatory utilizes a 3-axis-stabilized spacecraft which provides services such as power, attitude determination and control, commanding, and telemetry to the ground. During its 2-year baseline mission, IXPE will conduct precise polarimetry for samples of multiple categories of X-ray sources, with follow-on observations of selected targets.

astro-ph.IM

The Instrument of the Imaging X-ray Polarimetry Explorer

While X-ray Spectroscopy, Timing and Imaging have improved verymuch since 1962, when the first astronomical non-solar source was discovered, especially with the launch of Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detectors, in part due to the fate of approved missions and in part because the celestial X-ray sources appeared less polarized than expected. Only one positive measurement has been available until now. Indeed the eight Orbiting Solar Observatory measured the polarization of the Crab nebula in the 70s. The advent of techniques of microelectronics allowed for designing a detector based on the photoelectric effect in gas in an energy range where the optics are efficient in focusing X-rays. Herewe describe the Instrument, which is the major contribution of the Italian collaboration to the SmallExplorer mission called IXPE, the Imaging X-ray Polarimetry Explorer, which will be flown in late 2021. The instrument, is composed of three Detector Units, based on this technique, and a Detector Service Unit. Three Mirror Modules provided by Marshall Space Flight Center focus X-rays onto the detectors. In the following we will show the technological choices, their scientific motivation and the results from the calibration of the Instrument. IXPE will perform imaging, timing and energy resolved polarimetry in the 2-8 keV energy band opening this window of X-ray astronomy to tens of celestial sources of almost all classes.

astro-ph.IM

X-ray polarimetry of the Crab nebula with PolarLight: polarization recovery after the glitch and a secular position angle variation

We report follow-up observations of the Crab nebula with the PolarLight X-ray polarimeter, which revealed a possible variation in polarization associated with a pulsar glitch in 2019. The new observations confirm that the polarization has recovered roughly 100 days after the glitch. With the new observations, we find that the polarization angle (PA) measured with PolarLight from the total nebular emission has a difference of 18.0 +- 4.6 (deg) from that measured 42 years ago with OSO-8, indicating a secular evolution of polarization with either the Crab nebula or pulsar. The long-term variation in PA could be a result of multiple glitches in the history, magnetic reconnection or movement of synchrotron emitting structures in the nebula, or secular evolution of the pulsar magnetic geometry.

astro-ph.HE

Discrimination of background events in the PolarLight X-ray polarimeter

PolarLight is a space-borne X-ray polarimeter that measures the X-ray polarization via electron tracking in an ionization chamber. It is a collimated instrument and thus suffers from the background on the whole detector plane. The majority of background events are induced by high energy charged particles and show ionization morphologies distinct from those produced by X-rays of interest. Comparing on-source and off-source observations, we find that the two datasets display different distributions on image properties. The boundaries between the source and background distributions are obtained and can be used for background discrimination. Such a means can remove over 70% of the background events measured with PolarLight. This approaches the theoretical upper limit of the background fraction that is removable and justifies its effectiveness. For observations with the Crab nebula, the background contamination decreases from 25% to 8% after discrimination, indicative of a polarimetric sensitivity of around 0.2 Crab for PolarLight. This work also provides insights into future X-ray polarimetric telescopes.

astro-ph.IM

Modeling the in-orbit background of PolarLight

PolarLight is a gas pixel X-ray polarimeter mounted on a CubeSat, which was launched into a Sun-synchronous orbit in October 2018. We build a mass model of the whole CubeSat with the Geant4 toolkit to simulate the background induced by the cosmic X-ray background (CXB) and high energy charged particles in the orbit. The simulated energy spectra and morphologies of event images both suggest that the measured background with PolarLight is dominated by high energy electrons, with a minor contribution from protons and the CXB. The simulation reveals that, in the energy range of 2-8 keV, there are roughly 28% of the background events are caused by energy deposit from a secondary electron with an energy of a few keV, in a physical process identical to the detection of X-rays. Thus, this fraction of background cannot be discriminated from X-ray events. The background distribution is uneven on the detector plane, with an enhancement near the edges. The edge effect is because high energy electrons tend to produce long tracks, which are discarded by the readout electronics unless they have partial energy deposits near the edges. The internal background rate is expected to be around 6 x 10^-3 counts/s/cm2 in 2-8 keV if an effective particle discrimination algorithm can be applied. This indicates that the internal background should be negligible for future focusing X-ray polarimeters with a focal size in the order of mm.

astro-ph.IM

Re-detection and a Possible Time Variation of Soft X-ray Polarisation from the Crab

The Crab nebula is so far the only celestial object with a statistically significant detection in soft x-ray polarimetry, a window that has not been explored in astronomy since the 1970s. However, soft x-ray polarimetry is expected to be a sensitive probe of magnetic fields in high energy astrophysical objects including rotation-powered pulsars and pulsar wind nebulae. Here we report the re-detection of soft x-ray polarisation after 40 years from the Crab nebula and pulsar with PolarLight, a miniature polarimeter utilising a novel technique onboard a CubeSat. The polarisation fraction of the Crab in the on-pulse phases was observed to decrease after a glitch of the Crab pulsar on July 23, 2019, while that of the pure nebular emission remained constant within uncertainty. The phenomenon may have lasted about 100 days. If the association between the glitch and polarisation change can be confirmed with future observations, it will place strong constraints on the physical mechanism of the high energy emission and glitch of pulsars.

astro-ph.HE

In-orbit Operation and Performance of the CubeSat Soft X-ray Polarimeter PolarLight

PolarLight is a compact soft X-ray polarimeter onboard a CubeSat, which was launched into a low-Earth orbit on October 29, 2018. In March 2019, PolarLight started full operation, and since then, regular observations with the Crab nebula, Sco X-1, and background regions have been conducted. Here we report the operation, calibration, and performance of PolarLight in the orbit. Based on these, we discuss how one can run a low-cost, shared CubeSat for space astronomy, and how CubeSats can play a role in modern space astronomy for technical demonstration, science observations, and student training.

astro-ph.IM

PolarLight: a CubeSat X-ray Polarimeter based on the Gas Pixel Detector

The gas pixel detector (GPD) is designed and developed for high-sensitivity astronomical X-ray polarimetry, which is a new window about to open in a few years. Due to the small mass, low power, and compact geometry of the GPD, we propose a CubeSat mission Polarimeter Light (PolarLight) to demonstrate and test the technology directly in space. There is no optics but a collimator to constrain the field of view to 2.3 degrees. Filled with pure dimethyl ether (DME) at 0.8 atm and sealed by a beryllium window of 100 micron thick, with a sensitive area of about 1.4 mm by 1.4 mm, PolarLight allows us to observe the brightest X-ray sources on the sky, with a count rate of, e.g., ~0.2 counts/s from the Crab nebula. The PolarLight is 1U in size and mounted in a 6U CubeSat, which was launched into a low Earth Sun-synchronous orbit on October 29, 2018, and is currently under test. More launches with improved designs are planned in 2019. These tests will help increase the technology readiness for future missions such as the enhanced X-ray Timing and Polarimetry (eXTP), better understand the orbital background, and may help constrain the physics with observations of the brightest objects.

astro-ph.IM

LAMP: a micro-satellite based soft X-ray polarimeter for astrophysics

The Lightweight Asymmetry and Magnetism Probe (LAMP) is a micro-satellite mission concept dedicated for astronomical X-ray polarimetry and is currently under early phase study. It consists of segmented paraboloidal multilayer mirrors with a collecting area of about 1300 cm^2 to reflect and focus 250 eV X-rays, which will be detected by position sensitive detectors at the focal plane. The primary targets of LAMP include the thermal emission from the surface of pulsars and synchrotron emission produced by relativistic jets in blazars. With the expected sensitivity, it will allow us to detect polarization or place a tight upper limit for about 10 pulsars and 20 blazars. In addition to measuring magnetic structures in these objects, LAMP will also enable us to discover bare quark stars if they exist, whose thermal emission is expected to be zero polarized, while the thermal emission from neutron stars is believed to be highly polarized due to plasma polarization and the quantum electrodynamics (QED) effect. Here we present an overview of the mission concept, its science objectives and simulated observational results.

astro-ph.IM

Re-testing the JET-X Flight Module No. 2 at the PANTER facility

The Joint European X-ray Telescope (JET-X) was the core instrument of the Russian Spectrum-X-gamma space observatory. It consisted of two identical soft X-ray (0.3 - 10 keV) telescopes with focusing optical modules having a measured angular resolution of nearly 15 arcsec. Soon after the payload completion, the mission was cancelled and the two optical flight modules (FM) were brought to the Brera Astronomical Observatory where they had been manufactured. After 16 years of storage, we have utilized the JET-X FM2 to test at the PANTER X-ray facility a prototype of a novel X-ray polarimetric telescope, using a Gas Pixel Detector (GPD) with polarimetric capabilities in the focal plane of the FM2. The GPD was developed by a collaboration between INFN-Pisa and INAF-IAPS. In the first phase of the test campaign, we have re-tested the FM2 at PANTER to have an up-to-date characterization in terms of angular resolution and effective area, while in the second part of the test the GPD has been placed in the focal plane of the FM2. In this paper we report the results of the tests of the sole FM2, using an unpolarized X-ray source, comparing the results with the calibration done in 1996.

astro-ph.IM

XIPE: the X-ray Imaging Polarimetry Explorer

X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and temporal variability measurements and to imaging, allows a wealth of physical phenomena in astrophysics to be studied. X-ray polarimetry investigates the acceleration process, for example, including those typical of magnetic reconnection in solar flares, but also emission in the strong magnetic fields of neutron stars and white dwarfs. It detects scattering in asymmetric structures such as accretion disks and columns, and in the so-called molecular torus and ionization cones. In addition, it allows fundamental physics in regimes of gravity and of magnetic field intensity not accessible to experiments on the Earth to be probed. Finally, models that describe fundamental interactions (e.g. quantum gravity and the extension of the Standard Model) can be tested. We describe in this paper the X-ray Imaging Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a small mission with a launch in 2017 but not selected. XIPE is composed of two out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD) filled with a He-DME mixture at their focus and two additional GPDs filled with pressurized Ar-DME facing the sun. The Minimum Detectable Polarization is 14 % at 1 mCrab in 10E5 s (2-10 keV) and 0.6 % for an X10 class flare. The Half Energy Width, measured at PANTER X-ray test facility (MPE, Germany) with JET-X optics is 24 arcsec. XIPE takes advantage of a low-earth equatorial orbit with Malindi as down-link station and of a Mission Operation Center (MOC) at INPE (Brazil).

astro-ph.HE

Measurement of the position resolution of the Gas Pixel Detector

The Gas Pixel Detector was designed and built as a focal plane instrument for X-ray polarimetry of celestial sources, the last unexplored subtopics of X-ray astronomy. It promises to perform detailed and sensitive measurements resolving extended sources and detecting polarization in faint sources in crowded fields at the focus of telescopes of good angular resolution. Its polarimetric and spectral capability were already studied in earlier works. Here we investigate for the first time, with both laboratory measurements and Monte Carlo simulations, its imaging properties to confirm its unique capability to carry out imaging spectral-polarimetry in future X-ray missions.

astro-ph.IM