Searcharxiv⌕ Search

arXiv subjects

Mateusz Trokielewicz

Publications and source records attributed to Mateusz Trokielewicz.

At least 19 recordsLinked to original sources

Synthetic Iris Image Databases and Identity Leakage: Risks and Mitigation Strategies

This paper presents a comprehensive overview of iris image synthesis methods, which can alleviate the issues associated with gathering large, diverse datasets of biometric data from living individuals, which are considered pivotal for biometric methods development. These methods for synthesizing iris data range from traditional, hand crafted image processing-based techniques, through various iterations of GAN-based image generators, variational autoencoders (VAEs), as well as diffusion models. The potential and fidelity in iris image generation of each method is discussed and examples of inferred predictions are provided. Furthermore, the risks of individual biometric features leakage from the training sets are considered, together with possible strategies for preventing them, which have to be implemented should these generative methods be considered a valid replacement of real-world biometric datasets.

cs.CV↗

Iris Recognition for Infants

Non-invasive, efficient, physical token-less, accurate and stable identification methods for newborns may prevent baby swapping at birth, limit baby abductions and improve post-natal health monitoring across geographies, within the context of both the formal (i.e., hospitals) and informal (i.e., humanitarian and fragile settings) health sectors. This paper explores the feasibility of application iris recognition to build biometric identifiers for 4-6 week old infants. We (a) collected near infrared (NIR) iris images from 17 infants using a specially-designed NIR iris sensor; (b) evaluated six iris recognition methods to assess readiness of the state-of-the-art iris recognition to be applied to newborns and infants; (c) proposed a new segmentation model that correctly detects iris texture within infants iris images, and coupled it with several iris texture encoding approaches to offer, to the first of our knowledge, a fully-operational infant iris recognition system; and, (d) trained a StyleGAN-based model to synthesize iris images mimicking samples acquired from infants to deliver to the research community privacy-safe infant iris images. The proposed system, incorporating the specially-designed iris sensor and segmenter, and applied to the collected infant iris samples, achieved Equal Error Rate (EER) of 3\% and Area Under ROC Curve (AUC) of 99\%, compared to EER$\geq$20\% and AUC$\leq$88\% obtained for state of the art adult iris recognition systems. This suggests that it may be feasible to design methods that succesfully extract biometric features from infant irises.

cs.CV↗

Iris Liveness Detection Competition (LivDet-Iris) -- The 2020 Edition

Launched in 2013, LivDet-Iris is an international competition series open to academia and industry with the aim to assess and report advances in iris Presentation Attack Detection (PAD). This paper presents results from the fourth competition of the series: LivDet-Iris 2020. This year's competition introduced several novel elements: (a) incorporated new types of attacks (samples displayed on a screen, cadaver eyes and prosthetic eyes), (b) initiated LivDet-Iris as an on-going effort, with a testing protocol available now to everyone via the Biometrics Evaluation and Testing (BEAT)(https://www.idiap.ch/software/beat/) open-source platform to facilitate reproducibility and benchmarking of new algorithms continuously, and (c) performance comparison of the submitted entries with three baseline methods (offered by the University of Notre Dame and Michigan State University), and three open-source iris PAD methods available in the public domain. The best performing entry to the competition reported a weighted average APCER of 59.10\% and a BPCER of 0.46\% over all five attack types. This paper serves as the latest evaluation of iris PAD on a large spectrum of presentation attack instruments.

cs.CV↗

Post-Mortem Iris Recognition Resistant to Biological Eye Decay Processes

This paper proposes an end-to-end iris recognition method designed specifically for post-mortem samples, and thus serving as a perfect application for iris biometrics in forensics. To our knowledge, it is the first method specific for verification of iris samples acquired after demise. We have fine-tuned a convolutional neural network-based segmentation model with a large set of diversified iris data (including post-mortem and diseased eyes), and combined Gabor kernels with newly designed, iris-specific kernels learnt by Siamese networks. The resulting method significantly outperforms the existing off-the-shelf iris recognition methods (both academic and commercial) on the newly collected database of post-mortem iris images and for all available time horizons since death. We make all models and the method itself available along with this paper.

cs.CV↗

Post-mortem Iris Decomposition and its Dynamics in Morgue Conditions

With increasing interest in employing iris biometrics as a forensic tool for identification by investigation authorities, there is a need for a thorough examination and understanding of post-mortem decomposition processes that take place within the human eyeball, especially the iris. This can prove useful for fast and accurate matching of ante-mortem with post-mortem data acquired at crime scenes or mass casualties, as well as for ensuring correct dispatching of bodies from the incident scene to a mortuary or funeral homes. Following these needs of forensic community, this paper offers an analysis of the coarse effects of eyeball decay done from a perspective of automatic iris recognition point of view. Therefore, we analyze post-mortem iris images acquired in both visible light as well as in near-infrared light (860 nm), as the latter wavelength is used in commercial iris recognition systems. Conclusions and suggestions are provided that may aid forensic examiners in successfully utilizing iris patterns in post-mortem identification of deceased subjects. Initial guidelines regarding the imaging process, types of illumination, resolution are also given, together with expectations with respect to the iris features decomposition rates.

cs.CV↗

Perception of Image Features in Post-Mortem Iris Recognition: Humans vs Machines

Post-mortem iris recognition can offer an additional forensic method of personal identification. However, in contrary to already well-established human examination of fingerprints, making iris recognition human-interpretable is harder, and therefore it has never been applied in forensic proceedings. There is no strong consensus among biometric experts which iris features, especially those in iris images acquired post-mortem, are the most important for human experts solving an iris recognition task. This paper explores two ways of broadening this knowledge: (a) with an eye tracker, the salient features used by humans comparing iris images on a screen are extracted, and (b) class-activation maps produced by the convolutional neural network solving the iris recognition task are analyzed. Both humans and deep learning-based solutions were examined with the same set of iris image pairs. This made it possible to compare the attention maps and conclude that (a) deep learning-based method can offer human-interpretable decisions backed by visual explanations pointing a human examiner to salient regions, and (b) in many cases humans and a machine used different features, what means that a deep learning-based method can offer a complementary support to human experts. This paper offers the first known to us human-interpretable comparison of machine-based and human-based post-mortem iris recognition, and the trained models annotating salient iris image regions.

cs.CV↗

Post-mortem Iris Recognition with Deep-Learning-based Image Segmentation

This paper proposes the first known to us iris recognition methodology designed specifically for post-mortem samples. We propose to use deep learning-based iris segmentation models to extract highly irregular iris texture areas in post-mortem iris images. We show how to use segmentation masks predicted by neural networks in conventional, Gabor-based iris recognition method, which employs circular approximations of the pupillary and limbic iris boundaries. As a whole, this method allows for a significant improvement in post-mortem iris recognition accuracy over the methods designed only for ante-mortem irises, including the academic OSIRIS and commercial IriCore implementations. The proposed method reaches the EER less than 1% for samples collected up to 10 hours after death, when compared to 16.89% and 5.37% of EER observed for OSIRIS and IriCore, respectively. For samples collected up to 369 hours post-mortem, the proposed method achieves the EER 21.45%, while 33.59% and 25.38% are observed for OSIRIS and IriCore, respectively. Additionally, the method is tested on a database of iris images collected from ophthalmology clinic patients, for which it also offers an advantage over the two other algorithms. This work is the first step towards post-mortem-specific iris recognition, which increases the chances of identification of deceased subjects in forensic investigations. The new database of post-mortem iris images acquired from 42 subjects, as well as the deep learning-based segmentation models are made available along with the paper, to ensure all the results presented in this manuscript are reproducible.

cs.CV↗

Learning-Free Iris Segmentation Revisited: A First Step Toward Fast Volumetric Operation Over Video Samples

Subject matching performance in iris biometrics is contingent upon fast, high-quality iris segmentation. In many cases, iris biometrics acquisition equipment takes a number of images in sequence and combines the segmentation and matching results for each image to strengthen the result. To date, segmentation has occurred in 2D, operating on each image individually. But such methodologies, while powerful, do not take advantage of potential gains in performance afforded by treating sequential images as volumetric data. As a first step in this direction, we apply the Flexible Learning-Free Reconstructoin of Neural Volumes (FLoRIN) framework, an open source segmentation and reconstruction framework originally designed for neural microscopy volumes, to volumetric segmentation of iris videos. Further, we introduce a novel dataset of near-infrared iris videos, in which each subject's pupil rapidly changes size due to visible-light stimuli, as a test bed for FLoRIN. We compare the matching performance for iris masks generated by FLoRIN, deep-learning-based (SegNet), and Daugman's (OSIRIS) iris segmentation approaches. We show that by incorporating volumetric information, FLoRIN achieves a factor of 3.6 to an order of magnitude increase in throughput with only a minor drop in subject matching performance. We also demonstrate that FLoRIN-based iris segmentation maintains this speedup on low-resource hardware, making it suitable for embedded biometrics systems.

cs.CV↗

Iris Recognition with Image Segmentation Employing Retrained Off-the-Shelf Deep Neural Networks

This paper offers three new, open-source, deep learning-based iris segmentation methods, and the methodology how to use irregular segmentation masks in a conventional Gabor-wavelet-based iris recognition. To train and validate the methods, we used a wide spectrum of iris images acquired by different teams and different sensors and offered publicly, including data taken from CASIA-Iris-Interval-v4, BioSec, ND-Iris-0405, UBIRIS, Warsaw-BioBase-Post-Mortem-Iris v2.0 (post-mortem iris images), and ND-TWINS-2009-2010 (iris images acquired from identical twins). This varied training data should increase the generalization capabilities of the proposed segmentation techniques. In database-disjoint training and testing, we show that deep learning-based segmentation outperforms the conventional (OSIRIS) segmentation in terms of Intersection over Union calculated between the obtained results and manually annotated ground-truth. Interestingly, the Gabor-based iris matching is not always better when deep learning-based segmentation is used, and is on par with the method employing Daugman's based segmentation.

cs.CV↗

Performance of Humans in Iris Recognition: The Impact of Iris Condition and Annotation-driven Verification

This paper advances the state of the art in human examination of iris images by (1) assessing the impact of different iris conditions in identity verification, and (2) introducing an annotation step that improves the accuracy of people's decisions. In a first experimental session, 114 subjects were asked to decide if pairs of iris images depict the same eye (genuine pairs) or two distinct eyes (impostor pairs). The image pairs sampled six conditions: (1) easy for algorithms to classify, (2) difficult for algorithms to classify, (3) large difference in pupil dilation, (4) disease-affected eyes, (5) identical twins, and (6) post-mortem samples. In a second session, 85 of the 114 subjects were asked to annotate matching and non-matching regions that supported their decisions. Subjects were allowed to change their initial classification as a result of the annotation process. Results suggest that: (a) people improve their identity verification accuracy when asked to annotate matching and non-matching regions between the pair of images, (b) images depicting the same eye with large difference in pupil dilation were the most challenging to subjects, but benefited well from the annotation-driven classification, (c) humans performed better than iris recognition algorithms when verifying genuine pairs of post-mortem and disease-affected eyes (i.e., samples showing deformations that go beyond the distortions of a healthy iris due to pupil dilation), and (d) annotation does not improve accuracy of analyzing images from identical twins, which remain confusing for people.

cs.CV↗

Iris Recognition After Death

This paper presents a comprehensive study of post-mortem human iris recognition carried out for 1,200 near-infrared and 1,787 visible-light samples collected from 37 deceased individuals kept in the mortuary conditions. We used four independent iris recognition methods (three commercial and one academic) to analyze genuine and impostor comparison scores and check the dynamics of iris quality decay over a period of up to 814 hours after death. This study shows that post-mortem iris recognition may be close-to-perfect approximately 5 to 7 hours after death and occasionally is still viable even 21 days after death. These conclusions contradict the statements present in past literature that the iris is unusable as a biometrics shortly after death, and show that the dynamics of post-mortem changes to the iris that are important for biometric identification are more moderate than previously hypothesized. The paper contains a thorough medical commentary that helps to understand which post-mortem metamorphoses of the eye may impact the performance of automatic iris recognition. We also show that post-mortem iris recognition works equally well for images taken in near-infrared and when the red channel of visible-light sample is used. However, cross-wavelength matching presents significantly worse performance. This paper conforms to reproducible research and the database used in this study is made publicly available to facilitate research of post-mortem iris recognition. To our knowledge, this paper offers the most comprehensive evaluation of post-mortem iris recognition and the largest database of post-mortem iris images.

cs.CV↗

Thermal Features for Presentation Attack Detection in Hand Biometrics

This paper proposes a method for utilizing thermal features of the hand for the purpose of presentation attack detection (PAD) that can be employed in a hand biometrics system's pipeline. By envisaging two different operational modes of our system, and by employing a DCNN-based classifiers fine-tuned with a dataset of real and fake hand representations captured in both visible and ther- mal spectrum, we were able to bring two important deliverables. First, a PAD method operating in an open-set mode, capable of correctly discerning 100% of fake thermal samples, achieving Attack Presentation Classification Error Rate (APCER) and Bona-Fide Presentation Classification Error Rate (BPCER) equal to 0%, which can be easily implemented into any existing system as a separate component. Second, a hand biometrics system operating in a closed-set mode, that has PAD built right into the recognition pipeline, and operating simultaneously with the user-wise classification, achieving rank-1 recognition accuracy of up to 99.75%. We also show that thermal images of the human hand, in addition to liveness features they carry, can also improve classification accuracy of a biometric system, when coupled with visible light images. To follow the reproducibility guidelines and to stimulate further research in this area, we share the trained model weights, source codes, and a newly created dataset of fake hand representations with interested researchers.

cs.CV↗

Iris recognition in cases of eye pathology

This chapter provides insight on how iris recognition, one of the leading biometric identification technologies in the world, can be impacted by pathologies and illnesses present in the eye, what are the possible repercussions of this influence, and what are the possible means for taking such effects into account when matching iris samples. To make this study possible, a special database of iris images has been used, representing more than 20 different medical conditions of the ocular region (including cataract, glaucoma, rubeosis iridis, synechiae, iris defects, corneal pathologies and other) and containing almost 3000 samples collected from 230 distinct irises. Then, with the use of four different iris recognition methods, a series of experiments has been conducted, concluding in several important observations. One of the most popular ocular disorders worldwide - the cataract - is shown to worsen genuine comparison scores when results obtained from cataract-affected eyes are compared to those coming from healthy irises. An analysis devoted to different types of impact on eye structures caused by diseases is also carried out with significant results. The enrollment process is highly sensitive to those eye conditions that make the iris obstructed or introduce geometrical distortions. Disorders affecting iris geometry, or producing obstructions are exceptionally capable of degrading the genuine comparison scores, so that the performance of the entire biometric system can be influenced. Experiments also reveal that imperfect execution of the image segmentation stage is the most prominent contributor to recognition errors.

cs.CV↗

Implications of Ocular Pathologies for Iris Recognition Reliability

This paper presents an analysis of how iris recognition is influenced by eye disease and an appropriate dataset comprising 2996 images of irises taken from 230 distinct eyes (including 184 affected by more than 20 different eye conditions). The images were collected in near infrared and visible light during routine ophthalmological examination. The experimental study carried out utilizing four independent iris recognition algorithms (MIRLIN, VeriEye, OSIRIS and IriCore) renders four valuable results. First, the enrollment process is highly sensitive to those eye conditions that obstruct the iris or cause geometrical distortions. Second, even those conditions that do not produce visible changes to the structure of the iris may increase the dissimilarity between samples of the same eyes. Third, eye conditions affecting the geometry or the tissue structure of the iris or otherwise producing obstructions significantly decrease same-eye similarity and have a lower, yet still statistically significant, influence on impostor comparison scores. Fourth, for unhealthy eyes, the most prominent effect of disease on iris recognition is to cause segmentation errors. To our knowledge this paper describes the largest database of iris images for disease-affected eyes made publicly available to researchers and offers the most comprehensive study of what we can expect when iris recognition is employed for diseased eyes.

cs.CV↗

Assessment of iris recognition reliability for eyes affected by ocular pathologies

This paper presents an analysis of how the iris recognition is impacted by eye diseases and an appropriate dataset comprising 2996 iris images of 230 distinct eyes (including 184 illness-affected eyes representing more than 20 different eye conditions). The images were collected in near infrared and visible light during a routine ophthalmological practice. The experimental study shows four valuable results. First, the enrollment process is highly sensitive to those eye conditions that make the iris obstructed or introduce geometrical distortions. Second, even those conditions that do not produce visible changes to the iris structure may increase the dissimilarity among samples of the same eyes. Third, eye conditions affecting iris geometry, its tissue structure or producing obstructions significantly decrease the iris recognition reliability. Fourth, for eyes afflicted by a disease, the most prominent effect of the disease on iris recognition is to cause segmentation errors. To our knowledge this is the first database of iris images for disease-affected eyes made publicly available to researchers, and the most comprehensive study of what we can expect when the iris recognition is deployed for non-healthy eyes.

cs.CV↗

Human Iris Recognition in Post-mortem Subjects: Study and Database

This paper presents a unique study of post-mortem human iris recognition and the first known to us database of near-infrared and visible-light iris images of deceased humans collected up to almost 17 days after death. We used four different iris recognition methods to analyze the dynamics of iris quality decay in short-term comparisons (samples collected up to 60 hours after death) and long-term comparisons (for samples acquired up to 407 hours after demise). This study shows that post-mortem iris recognition is possible and occasionally works even 17 days after death. These conclusions contradict a promulgated rumor that iris is unusable shortly after decease. We make this dataset publicly available to let others verify our findings and to research new aspects of this important and unfamiliar topic. We are not aware of any earlier papers offering post-mortem human iris images and such comprehensive analysis employing four different matchers.

cs.CV↗

Iris and periocular recognition in arabian race horses using deep convolutional neural networks

This paper presents a study devoted to recognizing horses by means of their iris and periocular features using deep convolutional neural networks (DCNNs). Identification of race horses is crucial for animal identity confirmation prior to racing. As this is usually done shortly before a race, fast and reliable methods that are friendly and inflict no harm upon animals are important. Iris recognition has been shown to work with horse irides, provided that algorithms deployed for such task are fine-tuned for horse irides and input data is of very high quality. In our work, we examine a possibility of utilizing deep convolutional neural networks for a fusion of both iris and periocular region features. With such methodology, ocular biometrics in horses could perform well without employing complicated algorithms that require a lot of fine-tuning and prior knowledge of the input image, while at the same time being rotation, translation, and to some extent also image quality invariant. We were able to achieve promising results, with EER=9.5% using two network architectures with score-level fusion.

cs.CV↗

Database of iris images acquired in the presence of ocular pathologies and assessment of iris recognition reliability for disease-affected eyes

This paper presents a database of iris images collected from disease affected eyes and an analysis related to the influence of ocular diseases on iris recognition reliability. For that purpose we have collected a database of iris images acquired for 91 different eyes during routine ophthalmology visits. This collection gathers samples for healthy eyes as well as those with various eye pathologies, including cataract, acute glaucoma, posterior and anterior synechiae, retinal detachment, rubeosis iridis, corneal vascularization, corneal grafting, iris damage and atrophy and corneal ulcers, haze or opacities. To our best knowledge this is the first database of such kind that will be made publicly available. In the analysis the data were divided into five groups of samples presenting similar anticipated impact on iris recognition: 1) healthy (no impact), 2) unaffected, clear iris (although the illness was detected), 3) geometrically distorted irides, 4) distorted iris tissue and 5) obstructed iris tissue. Three different iris recognition methods (MIRLIN, VeriEye and OSIRIS) were then used to find differences in average genuine and impostor comparison scores calculated for healthy eyes and those impacted by a disease. Specifically, we obtained significantly worse genuine comparison scores for all iris matchers and all disease-affected eyes when compared to a group of healthy eyes, what have a high potential of impacting false non-match rate.

cs.CV↗