SearcharxivSearch

arXiv subjects

Matias Rodrigues

Publications and source records attributed to Matias Rodrigues.

3 recordsLinked to original sources

Measurements of absolute gamma-ray energies using an ultra-high energy resolution magnetic microcalorimeter

We present new measurements of 27 gamma ray energies ranging from 14 keV to 136 keV, obtained using high-energy-resolution magnetic microcalorimeters for energy-dispersive spectrometry. The spectrometer has eight pixels and achieves an energy resolution between 15 and 30 eV across the entire energy range. It faces a cryogenic source sampler with four movable sources. Each source contains a mixture of radionuclides, including Yb-169 and Co-57 used to calibrate the spectrometer and correct its non-linearity. The gamma-ray energies, emitted through the decay of Co-57, Cd-109, Ba-133, Gd-153, Eu-154, Eu-155, Yb-169, Tm-170, Pb-210, Np-239, Am-241 and Am-243, have been reassessed. The lowest absolute uncertainty achieved is 0.13 eV at 105.3 keV, which corresponds to a relative uncertainty of 1.3 ppm. Of the 27 measured gamma rays, the uncertainties of 19 energies were improved with respect to the available literature: 10 by a factor of 5 and 4 by more than one order of magnitude. Good agreement is observed with energies obtained elsewhere by wavelength-dispersive spectrometry. This work significantly improves upon previously reported gamma energies obtained by energy-dispersive spectrometry using semiconductor detectors, thanks to the ultra-high energy resolution of magnetic microcalorimeters.

physics.ins-det

Magnetic microcalorimeters for primary activity standardization within the EMPIR project PrimA-LTD

The precision of existing decay data of radionuclides for activity determination is often a limitation for actual applications in science, society, and industry. For this reason, the EMPIR project PrimA-LTD aims to introduce an advanced primary activity standardization technique that is based on magnetic microcalorimeters (MMCs) and that will offer very low energy threshold of few eV and a decay scheme independent detection efficiency close to 100%. As a proof of concept, we developed two MMC-based detector types in order to standardize an $\alpha$-decaying, a $\beta$-decaying and an electron capture decaying isotope. One detector type aims to introduce a reusable detector setup, while the other aims to provide highly accurate decay spectra by high resolution measurements with high statistics. We present the designs, fabrication status and first characterization measurements of both detectors types and outline next steps.

physics.ins-det

High precision measurement of the $^{99}$Tc $\beta$ spectrum

Highly precise measurements of the $^{99}$Tc beta spectrum were performed in two laboratories using metallic magnetic calorimeters. Independent sample preparations, evaluation methods and analyses yield consistent results and the spectrum could be measured down to less than 1 keV. Consistent beta spectra were also obtained via cross-evaluations of the experimental data sets. An additional independent measurement with silicon detectors in a $4\pi$ configuration confirms the spectrum shape above 25 keV. Detailed theoretical calculations were performed including nuclear structure and atomic effects. The spectrum shape was found to be sensitive to the effective value of the axial-vector coupling constant. Combining measurements and predictions, we extracted $Q_{\beta}=$295.82(16) keV and $g_A^{\text{eff}} = 1.530 (83)$. Furthermore, we derived the mean energy of the beta spectrum $\overline{E}_{\beta}$=98.45(20) keV, $\log f = -0.47660 (22)$ and $\log ft = 12.3478 (23)$.

nucl-ex