SearcharxivSearch

arXiv subjects

Matteo Accardo

Publications and source records attributed to Matteo Accardo.

5 recordsLinked to original sources

The status of the NIR arm of the SOXS Instrument toward the PAE

The Son Of X-Shooter (SOXS) is a single object spectrograph, built by an international consortium for the 3.58-m ESO New Technology Telescope at the La Silla Observatory [1]. It offers a simultaneous spectral coverage over 350-2000 nm, with two separate spectrographs. In this paper we present the status of the Near InfraRed (NIR) cryogenic echelle cross-dispersed spectrograph [1], in the range 0.80-2.00 {\mu}m with 15 orders, equipped with an 2k x 2k Hawaii H2RG IR array from Teledyne, working at 40K, that is currently assembled and tested on the SOXS instrument, in the premises of INAF in Padova. We describe the different tests and results of the cryo, vacuum, opto-mechanics and detector subsystems that finally will be part of the PAE by ESO.

astro-ph.IM

Development status of the UV-VIS detector system of SOXS for the ESO-NTT telescope

SOXS will be the new spectroscopic facility for the ESO NTT telescope able to cover the optical and NIR bands by using two different arms: the UV-VIS (350-850 nm), and the NIR (800-2000 nm). In this article, we describe the development status of the visible camera cryostat, the architecture of the acquisition system and the progress in the electronic design. The UV-VIS detector system is based on a CCD detector 44-82 from e2v, a custom detector head, coupled with the ESO continuous flow cryostats (CFC), a custom cooling system, based on a Programmable Logic Controller (PLC), and the New General Controller (NGC) developed by ESO. This paper outlines the development status of the system, describes the design of the different parts that make up the UV-VIS arm and is accompanied by a series of information describing the SOXS design solutions in the mechanics and in the electronics parts. The first tests of the detector system with the UV-VIS camera will be shown.

astro-ph.IM

Detector Systems Engineering for Extremely Large Instruments

The scientific detector systems for the ESO ELT first-light instruments, HARMONI, MICADO, and METIS, together will require 27 science detectors: seventeen 2.5 $\mu$m cutoff H4RG-15 detectors, four 4K x 4K 231-84 CCDs, five 5.3 $\mu$m cutoff H2RG detectors, and one 13.5 $\mu$m cutoff GEOSNAP detector. This challenging program of scientific detector system development covers everything from designing and producing state-of-the-art detector control and readout electronics, to developing new detector characterization techniques in the lab, to performance modeling and final system verification. We report briefly on the current design of these detector systems and developments underway to meet the challenging scientific performance goals of the ELT instruments.

astro-ph.IM

Multiple Star Systems in the Orion Nebula

This work presents an interferometric study of the massive-binary fraction in the Orion Trapezium Cluster with the recently comissioned GRAVITY instrument. We observe a total of 16 stars of mainly OB spectral type. We find three previously unknown companions for $\theta ^1$ Ori B, $\theta ^2$ Ori B, and $\theta ^2$ Ori C. We determine a separation for the previously suspected companion of NU Ori. We confirm four companions for $\theta ^1$ Ori A, $\theta ^1$ Ori C, $\theta ^1$ Ori D, and $\theta ^2$ Ori A, all with substantially improved astrometry and photometric mass estimates. We refine the orbit of the eccentric high-mass binary $\theta ^1$ Ori C and we are able to derive a new orbit for $\theta ^1$ Ori D. We find a system mass of 21.7 $M_{\odot}$ and a period of $53$ days. Together with other previously detected companions seen in spectroscopy or direct imaging, eleven of the 16 high-mass stars are multiple systems. We obtain a total number of 22 companions with separations up to 600 AU. The companion fraction of the early B and O stars in our sample is about 2, significantly higher than in earlier studies of mostly OB associations. The separation distribution hints towards a bimodality. Such a bimodality has been previously found in A stars, but rarely in OB binaries, which up to this point have been assumed to be mostly compact with a tail of wider companions. We also do not find a substantial population of equal-mass binaries. The observed distribution of mass ratios declines steeply with mass, and like the direct star counts, indicates that our companions follow a standard power law initial mass function. Again, this is in contrast to earlier findings of flat mass ratio distributions in OB associations. We exclude collision as a dominant formation mechanism but find no clear preference for core accretion or competitive accretion.

astro-ph.SR

The PRIMA fringe sensor unit

The Fringe Sensor Unit (FSU) is the central element of the Phase Referenced Imaging and Micro-arcsecond Astrometry (PRIMA) dual-feed facility and provides fringe sensing for all observation modes, comprising off-axis fringe tracking, phase referenced imaging, and high-accuracy narrow-angle astrometry. It is installed at the Very Large Telescope Interferometer (VLTI) and successfully servoed the fringe tracking loop during the initial commissioning phase. Unique among interferometric beam combiners, the FSU uses spatial phase modulation in bulk optics to retrieve real-time estimates of fringe phase after spatial filtering. A R=20 spectrometer across the K-band makes the retrieval of the group delay signal possible. The FSU was integrated and aligned at the VLTI in summer 2008. It yields phase and group delay measurements at sampling rates up to 2 kHz, which are used to drive the fringe tracking control loop. During the first commissioning runs, the FSU was used to track the fringes of stars with K-band magnitudes as faint as m_K=9.0, using two VLTI Auxiliary Telescopes (AT) and baselines of up to 96 m. Fringe tracking using two Very Large Telescope (VLT) Unit Telescopes (UT) was demonstrated. During initial commissioning and combining stellar light with two ATs, the FSU showed its ability to improve the VLTI sensitivity in K-band by more than one magnitude towards fainter objects, which is of fundamental importance to achieve the scientific objectives of PRIMA.

astro-ph.IM