Searcharxiv⌕ Search

arXiv subjects

Matthew T. Rakher

Publications and source records attributed to Matthew T. Rakher.

21 records · Page 2Linked to original sources

Counterfactual computation revisited

Mitchison and Jozsa recently suggested that the "chained-Zeno" counterfactual computation protocol recently proposed by Hosten et al. is counterfactual for only one output of the computer. This claim was based on the existing abstract algebraic definition of counterfactual computation, and indeed according to this definition, their argument is correct. However, a more general definition (physically adequate) for counterfactual computation is implicitly assumed by Hosten et. al. Here we explain in detail why the protocol is counterfactual and how the "history tracking" method of the existing description inadequately represents the physics underlying the protocol. Consequently, we propose a modified definition of counterfactual computation. Finally, we comment on one of the most interesting aspects of the error-correcting protocol.

quant-ph↗

Validation of Lasing in Active Nanocavities

An unambiguous proof of lasing in an active nanocavity with ultrahigh spontaneous emission coupling factor (beta = 0.65) is presented. To distinguish the subtle lasing threshold features from possible material-related phenomena, such as saturable absorption in the gain medium, a series of active nanocavities with different values of beta have been designed to systematically approach the high-beta device. The demonstration of the lasing threshold is obtained through the observation of the transition from thermal to coherent light photon statistics that is well understood and identified in the beta << 1 lasing regime. The systematic investigation allows a more definitive validation of the onset of lasing in these active nanocavities.

physics.optics↗

Frequency control of photonic crystal membrane resonators by mono-layer deposition

We study the response of GaAs photonic crystal membrane resonators to thin film deposition. Slow spectral shifts of the cavity mode of several nanometers are observed at low temperatures, caused by cryo-gettering of background molecules. Heating the membrane resets the drift and shielding will prevent drift altogether. In order to explore the drift as a tool to detect surface layers, or to intentionally shift the cavity resonance frequency, we studied the effect of self-assembled monolayers of polypeptide molecules attached to the membranes. The 2 nm thick monolayers lead to a discrete step in the resonance frequency and partially passivate the surface.

cond-mat.mtrl-sci↗