SearcharxivSearch

arXiv subjects

Matthias Kausel

Publications and source records attributed to Matthias Kausel.

5 recordsLinked to original sources

Noninvasive ion fraction quantification of dual-species beams in synchrotrons

The ion composition of dual-species beams in synchrotrons is typically inferred from invasive measurements performed after beam extraction. This paper introduces a complementary noninvasive method to determine the ion composition of such beams directly inside the synchrotron. The approach is applicable to low- and medium-energy synchrotrons and to small relative mass-to-charge ratio offsets, typically at the 1e-4 level. The method exploits dispersive orbit offsets between the two species and corresponding frequency corrections applied by the synchrotron RF radial regulation loop. This capability is of particular interest for ongoing research on online monitoring in carbon ion beam therapy using mixed 4He2+ and 12C6+ beams, which feature a relative mass-to-charge ratio offset of 0.065%. The proposed method is analytically derived and tested with particle tracking simulations using Xsuite. Its applicability under realistic experimental conditions is demonstrated at the MedAustron facility using mixed 4He2+ and 12C6+ beams. The results show good agreement with independent post-extraction measurements.

physics.acc-ph

Characterizing the Delivered Spill Structure of Medical Proton and Carbon-Ion Beams at MedAustron using a High Frequency Silicon Carbide Readout

Medical synchrotrons are often used for testing instrumentation in high-energy physics or non-clinical research in medical physics. In many applications of medical synchrotrons, such as microdosimetry and ion imaging, precise knowledge of the spill structure and instantaneous particle rate is crucial. Conventional ionization chambers, while omnipresent in clinical settings, suffer from limitations in charge resolution and integration time, making single-particle detection at high dose rates unfeasible. To address these limitations, we present a beam detection setup based on a silicon carbide (SiC) sensor and a monolithic microwave integrated circuit (MMIC), capable of detecting single particles with a full width at half maximum (FWHM) pulse duration of 500 ps. At the MedAustron ion therapy center, we characterized the spill structure of proton and carbon-ion beams delivered to the irradiation room beyond the timescale of the maximum ion revolution frequency in the synchrotron. The resulting data offer valuable insights into the beam intensity at small time scales and demonstrate the capabilities of SiC-based systems for high-flux beam monitoring.

physics.ins-det

A double multi-turn injection scheme for generating mixed helium and carbon ion beams at medical synchrotron facilities

The low relative charge-to-mass ratio offset of 0.065% between fully ionized helium-4 and carbon-12 ions enables simultaneous acceleration in hadron therapy synchrotrons. At the same energy per mass, helium ions exhibit a stopping range approximately three times greater than carbon ions. They can therefore be exploited for online range verification downstream of the patient during carbon ion beam irradiation. One possibility for creating this mixed beam is accelerating the two ion species sequentially through the LINAC and subsequently "mixing" them at injection energy in the synchrotron with a double multi-turn injection scheme. This work reports the first successful generation, acceleration, and extraction of a mixed helium and carbon ion beam using this double multi-turn injection scheme, which was achieved at the MedAustron therapy accelerator in Austria. A description of the double multi-turn injection scheme, particle tracking simulations, and details on the implementation at the MedAustron accelerator facility are presented and discussed. Finally, measurements of the mixed beam at delivery in the irradiation room using a radiochromic film and a low-gain avalanche diode (LGAD) detector are presented.

physics.acc-ph

First experimental time-of-flight-based proton radiography using low gain avalanche diodes

Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stopping power (RSP) distribution within a patient's body. Usually, this is done by estimating the path and energy loss of ions traversing the scanned volume via a tracking system and a separate residual energy detector. This study, on the other hand, introduces the first experimental study of a novel iCT approach based on time-of-flight (TOF) measurements, the so-called Sandwich TOF-iCT concept, which in contrast to any other iCT system, does not require a residual energy detector for the RSP determination. A small TOF-iCT demonstrator was built based on low gain avalanche diodes (LGAD), which are 4D-tracking detectors that allow to simultaneously measure the particle position and time-of-arrival with a precision better than 100um and 100ps, respectively. Using this demonstrator, the material and energy-dependent TOF was measured for several homogeneous PMMA slabs in order to calibrate the acquired TOF against the corresponding water equivalent thickness (WET). With this calibration, two proton radiographs (pRad) of a small aluminium stair phantom were recorded at MedAustron using 83 and 100.4MeV protons. Due to the simplified WET calibration models used in this very first experimental study of this novel approach, the difference between the measured and theoretical WET ranged between 37.09 and 51.12%. Nevertheless, the first TOF-based pRad was successfully recorded showing that LGADs are suitable detector candidates for TOF-iCT. While the system parameters and WET estimation algorithms require further optimization, this work was an important first step to realize Sandwich TOF-iCT. Due to its compact and cost-efficient design, Sandwich TOF-iCT has the potential to make iCT more feasible and attractive for clinical application, which, eventually, could enhance the treatment planning quality.

physics.med-ph

Wannier Diagram and Brown-Zak Fermions of Graphene on Hexagonal Boron-Nitride

The moiré potential of graphene on hexagonal boron nitride (hBN) generates a supercell sufficiently large as to thread a full magnetic flux quantum $Φ_0$ for experimentally accessible magnetic field strengths. Close to rational fractions of $Φ_0$, $p/q \cdotΦ_0$, magnetotranslation invariance is restored giving rise to Brown-Zak fermions featuring the same dispersion relation as in the absence of the field. Employing a highly efficient numerical approach we have performed the first realistic simulation of the magnetoconductance for a 250 nm wide graphene ribbon on hexagonal boron nitride using a full ab-initio derived parametrization including strain. The resulting Hofstadter butterfly is analyzed in terms of a novel Wannier diagram for Landau spectra of Dirac particles that includes the lifting of the spin and valley degeneracy by the magnetic field and the moiré potential. This complex diagram can account for many experimentally observed features on a single-particle level, such as spin and valley degeneracy lifting and a non-periodicidy in $Φ_0$.

cond-mat.mes-hall