SearcharxivSearch

arXiv subjects

Matthieu N. Boone

Publications and source records attributed to Matthieu N. Boone.

4 recordsLinked to original sources

Quantitative phase nano-imaging with a laboratory source

Investigating the structure of matter at the nanoscale non destructively is a key capability enabled by X-ray imaging. One of the most powerful nano-imaging methods is X-ray ptychography, a coherent diffraction imaging technique that has become the go-to method at synchrotron facilities for applications ranging from brain imaging to battery materials. However, the requirements in terms of X-ray beam quality have limited its use to large synchrotron facilities and, to date, only one attempt has been made to translate the technique to a small-scale laboratory. To unleash the power of this technique to the broad user community of laboratory X-ray sources, there are outstanding questions to answer including whether the quantitativeness of the information is preserved in a laboratory despite the drastic decrease in X-ray flux of several orders of magnitude, with respect to synchrotron instruments. In this study not only we demonstrate that the quantitativeness of X-ray ptychography is preserved in a laboratory setting, but we also apply the method to the imaging of a brain tissue phantom. Finally, we describe the current challenges and limitations, and we set the basis for further development and future directions of quantitative nano-imaging with laboratory X-ray sources.

physics.comp-ph

DYRECT Computed Tomography: DYnamic Reconstruction of Events on a Continuous Timescale

Time-resolved high-resolution X-ray Computed Tomography (4D $\mu$CT) is an imaging technique that offers insight into the evolution of dynamic processes inside materials that are opaque to visible light. Conventional tomographic reconstruction techniques are based on recording a sequence of 3D images that represent the sample state at different moments in time. This frame-based approach limits the temporal resolution compared to dynamic radiography experiments due to the time needed to make CT scans. Moreover, it leads to an inflation of the amount of data and thus to costly post-processing computations to quantify the dynamic behaviour from the sequence of time frames, hereby often ignoring the temporal correlations of the sample structure. Our proposed 4D $\mu$CT reconstruction technique, named DYRECT, estimates individual attenuation evolution profiles for each position in the sample. This leads to a novel memory-efficient event-based representation of the sample, using as little as three image volumes: its initial attenuation, its final attenuation and the transition times. This third volume represents local events on a continuous timescale instead of the discrete global time frames. We propose a method to iteratively reconstruct the transition times and the attenuation volumes. The dynamic reconstruction technique was validated on synthetic ground truth data and experimental data, and was found to effectively pinpoint the transition times in the synthetic dataset with a time resolution corresponding to less than a tenth of the amount of projections required to reconstruct traditional $\mu$CT time frames.

eess.IV

X-ray Tomographic Micro-Particle Velocimetry in Porous Media

Fluid flow through intricate confining geometries often exhibits complex behaviors, certainly in porous materials, e.g. in groundwater flows or the operation of filtration devices and porous catalysts. However, it has remained extremely challenging to measure 3D flow fields in such micrometer-scale geometries. Here, we introduce a new 3D velocimetry approach for optically opaque porous materials, based on time-resolved X-ray micro-computed tomography (micro-CT). We imaged the movement of X-ray tracing micro-particles in creeping flows through the pores of a sandpack and a porous filter, using laboratory-based micro-CT at frame rates of tens of seconds and voxel sizes of 12 micron. For both experiments, fully three-dimensional velocity fields were determined based on thousands of individual particle trajectories, showing a good match to computational fluid dynamics simulations. Error analysis was performed by investigating a realistic simulation of the experiments. The method has the potential to measure complex, unsteady 3D flows in porous media and other intricate microscopic geometries. This could cause a breakthrough in the study of fluid dynamics in a range of scientific and industrial application fields.

physics.flu-dyn

X-ray Ptychography with a Laboratory Source

X-ray ptychography has revolutionised nanoscale phase contrast imaging at large-scale synchrotron sources in recent years. We present here the first successful demonstration of the technique in a small-scale laboratory setting. We conducted an experiment with a liquid metal-jet X-ray source and a single photon-counting detector with a high spectral resolution. The experiment used a spot size of 5 microns to produce a ptychographic phase image of a Siemens star test pattern with a sub-micron spatial resolution. The result and methodology presented show how high-resolution phase contrast imaging can now be performed at small-scale laboratory sources worldwide.

physics.app-ph