SearcharxivSearch

arXiv subjects

Mattia Soldani

Publications and source records attributed to Mattia Soldani.

9 recordsLinked to original sources

Satellite-borne $\gamma$-ray astrophysics from coherent interactions in oriented crystals

High-density and high-Z crystals are key elements of most space-borne $\gamma$-ray telescopes operating at gigaelectronvolt energies (such as Fermi-LAT). The lattice structure is usually neglected in the development of a crystalline detector, although its effects on the energy deposit development should be taken into account, since the interactions of a high-energy ($\sim$ 10~GeV) photon or e$^\pm$ impinging along the axis of an oriented crystal are different than those observed in a fully isotropic medium. Specifically, if the angle between a photon (e$^\pm$) trajectory, and the crystal axis is smaller than $\sim$ 0.1$^\circ$, a large enhancement of the pair production (bremsstrahlung) cross section is observed. Consequently, a photon-induced shower inside an oriented crystal develops within a much more compact region than in an amorphous medium. Moreover, for photon energies above a few gigaelectronvolt and incidence angles up to several degrees, the pair production cross section exhibits a pronounced dependence on the angle between the crystal axis and the photon polarization vector. In this work we show that these effects could be exploited to develop a novel class of light-weight pointing space-borne $\gamma$-ray telescopes, capable of achieving an improved sensitivity and resolution, thanks to a better shower containment in a smaller volume, with respect to non-oriented crystalline detectors. We also show that an oriented tracker-converter system could be used to measure the polarization of a $\gamma$-ray source above few gigaelectronvolts, in a regime that remains unexplorable through any other detection technique. This novel detector concept could open new pathways in the study of the physics of extreme astrophysical environments and potentially improve the detector sensitivity for indirect dark matter searches in space

astro-ph.HE

High-Precision Alignment Techniques for Realizing an Ultracompact Electromagnetic Calorimeters Using Oriented high-Z Scintillator Crystals

Electromagnetic calorimeters used in high-energy physics and astrophysics rely heavily on high-Z inorganic scintillators, such as lead tungstate (PbWO4 or PWO). The crystalline structure and lattice orientation of inorganic scintillators are frequently underestimated in detector design, even though it is known that the crystalline lattice strongly modifies the features of the electromagnetic processes inside the crystal. A novel method has been developed for precisely bonding PWO crystals with aligned atomic planes within 100 μrad, exploiting X-ray diffraction (XRD) to accurately measure miscut angles. This method demonstrates the possibility to align a layer of crystals along the same crystallographic direction, opening a new technological path towards the development of next-generation electromagnetic calorimeters.

physics.ins-det

FCC-ee positron source from conventional to crystal-based

The high-luminosity requirement in future lepton colliders imposes a need for a high-intensity positron source. In the conventional scheme, positron beams are obtained by the conversion of bremsstrahlung photons into electron-positron pairs through the interaction between a high-energy electron beam and a high-Z amorphous target. One method to enhance the number of produced positrons is by boosting the incident electron beam power. However, the maximum heat load and thermo-mechanical stresses bearable by the target severely limit the beam power of the incident electrons. To overcome these limitations, an innovative approach using lattice coherent effects in oriented crystals appears promising. This approach uses a single thick crystal that serves as a radiator and a converter. In this paper, we investigate the application of this scheme as an alternative to the conventional positron source at the Future Circular Collider (FCC-ee). Simulations were carried out from the positron production stage to the entrance of the damping ring to estimate the accepted positron yield. The results demonstrate the advantages of the crystal-based positron source: it requires thinner targets than the conventional scheme, resulting in a 14% reduction in the deposited power while achieving a 10% increase in accepted positron yield.

physics.acc-ph

Proposal of the KOTO II experiment

The KOTO II experiment is proposed to measure the branching ratio of the decay $K_L\toπ^0ν\barν$ at J-PARC. With a beamline to extract long-lived neutral kaons at 5 degrees from a production target, the single event sensitivity of the decay is $8.5\times 10^{-13}$, which is much smaller than the Standard Model prediction $3\times 10^{-11}$. This allows searches for new physics beyond the Standard Model and the first discovery of the decay with a significance exceeding $5σ$. As the only experiment proposed in the world dedicated to rare kaon decays, KOTO II will be indispensable in the quest for a complete understanding of flavor dynamics in the quark sector. Moreover, by combining efforts from the kaon community worldwide, we plan to develop the KOTO II detector further and expand the physics reach of the experiment to include measurements of the branching ratio of the $K_L\toπ^0\ell^+\ell^-$ decays, studies of other $K_L$ decays, and searches for dark photons, axions, and axion-like particles. KOTO II will therefore obtain a comprehensive understanding of $K_L$ decays, providing further constraints on new physics scenarios with existing $K^+$ results.

hep-ex

Particle identification capability of a homogeneous calorimeter composed of oriented crystals

Recent studies have shown that the electromagnetic shower induced by a high-energy electron, positron or photon incident along the axis of an oriented crystal develops in a space more compact than the ordinary. On the other hand, the properties of the hadronic interactions are not affected by the lattice structure. This means that, inside an oriented crystal, the natural difference between the hadronic and the electromagnetic shower profile is strongly accentuated. Thus, a calorimeter composed of oriented crystals could be intrinsically capable of identifying more accurately the nature of the incident particles, with respect to a detector composed only of non-aligned crystals. Since no oriented calorimeter has ever been developed, this possibility remains largely unexplored and can be investigated only by mean of numerical simulations. In this work, we report the first quantitative evaluation of the particle identification capability of such a calorimeter, focusing on the case of neutron-gamma discrimination. We demonstrate through Geant4 simulations that the use of oriented crystals significantly improves the performance of a Random Forest classifier trained on the detector data. This work is a proof that oriented calorimeters could be a viable option for all the environments where particle identification must be performed with a very high accuracy, such as future high-intensity particle physics experiments and satellite-based gamma-ray telescopes.

hep-ex

Bent Crystal Design and Characterization for High-Energy Physics Experiments

Bent crystal are widely used as optics for X-rays, but via the phenomenon of planar channeling they may act as waveguide for relativistic charged particles beam as well, outperforming some of the traditional technologies currently employed. A physical description of the phenomenon and the resulting potential for applications in a particle accelerator is reported. The elastic properties of the anisotropic crystal lattice medium are discussed, introducing different types of curvature which can enable a wide array of bending schemes optimized for each different case features. The technological development of machining strategy and bending solutions useful for the fabrication of crystals suitable in high energy particle manipulations are described. As well as the high precision characterization processes developed in order to satisfy the strict requirements for installation in an accelerator. Finally, the characterization of channeling phenomenon in bent crystal is described, pointing out several experimental setups suitable to comply each specific case constrains.

physics.acc-ph

Strong Enhancement of Electromagnetic Shower Development in Oriented Scintillating Crystals and Implications for Particle Detectors

A particle traversing a crystal aligned with one of its crystallographic axes experiences a strong electromagnetic field that is constant along the direction of motion over macroscopic distances. For $e^\pm$ and $\gamma$-rays with energies above a few $\mathrm{GeV}$, this field is amplified by the Lorentz boost, to the point of exceeding the Schwinger critical field $\mathcal{E}_0 \sim 1.32 \times 10^{16}~\mathrm{V/cm}$. In this regime, nonlinear quantum-electrodynamical effects occur, such as the enhancement of intense electromagnetic radiation emission and pair production, so that the electromagnetic shower development is accelerated and the effective shower length is reduced compared to amorphous materials. We have investigated this phenomenon in lead tungstate (PbWO$_4$), a high-$Z$ scintillator widely used in particle detection. We have observed a substantial increase in scintillation light at small incidence angles with respect to the main lattice axes. Measurements with $120$-$\mathrm{GeV}$ electrons and $\gamma$-rays between $5$ and $100~\mathrm{GeV}$ demonstrate up to a threefold increase in energy deposition in oriented samples. These findings challenge the current models of shower development in crystal scintillators and could guide the development of next-generation accelerator- and space-borne detectors.

hep-ex

Radiation in oriented crystals: Innovative application to future positron sources

It has been known since decades that the alignment of a beam of high-energy electrons with particular crystal directions involves a significant increase of bremsstrahlung radiation emission. This enhancement lies at the conceptual foundation of innovative positron source schemes for future lepton colliders. In particular, the so-called hybrid scheme makes use of a heavy-metal radiator in crystalline form, which is then followed by an amorphous metallic converter for positron generation from electrons by means of a two-step electromagnetic process. This work presents the most recent simulation results obtained on the development of a hybrid positron source for the FCC-$ee$ from the standpoint of the features of both the crystalline radiator and the amorphous converter.

physics.acc-ph

A study of muon-electron elastic scattering in a test beam

In 2018, a test run with muons in the North Area at CERN was performed, running parasitically downstream of the COMPASS spectrometer. The aim of the test was to investigate the elastic interactions of muons on atomic electrons, in an experimental configuration similar to the one proposed by the project MUonE, which plans to perform a very precise measurement of the differential cross-section of the elastic interactions. COMPASS was taking data with a 190 GeV pion beam, stopped in a tungsten beam dump: the muons from these pions decays passed through a setup including a graphite target followed by 10 planes of Si tracker and a BGO crystal electromagnetic calorimeter placed at the end of the tracker. The elastic scattering events were analysed, and compared to expectations from MonteCarlo simulation.

hep-ex