SearcharxivSearch

arXiv subjects

Mauricio Alvarado

Publications and source records attributed to Mauricio Alvarado.

4 recordsLinked to original sources

The MexNICA Collaboration in the MPD-NICA Experiment at JINR: Experimental and Theoretical Achievements

The MexNICA Collaboration coordinates the activities of Mexican scientists, engineers, postdoctoral fellows and students in the Multi-Purpose Detector experiment at the Nuclotron-based Ion Collider fAcility of the Joint Institute for Nuclear Research in Dubna, Russia. Established in 2016, the collaboration brings together five Mexican institutions whose contributions span detector development as well phenomenological and theoretical studies, including modeling by means of Monte Carlo simulations. This work summarizes the main achievements of MexNICA, consisting of the development of the miniBeBe trigger detector as well of results of phenomenological investigations of the baryon-rich region in the QCD phase diagram accessible at NICA energies, and theoretical advances based on lattice QCD and effective models.

nucl-ex

Mechanical design concept version 2.0 for the miniBeBe subsystem of the Multi-Purpose Detector at the Nuclotron-based Ion Collider fAcility of the Joint Institute for Nuclear Research

We present the design of the mechanical structure of the mini Beam-Beam detector, a subsystem of the Multi-Purpose Detector, soon to enter into operation at the Nuclotron based Ion Collider fAcility of the Joint Institute for Nuclear Research. The miniBeBe detector was designed and is currently being developed by the Mexican team of the NICA Collaboration to contribute to the level-zero trigger of the Time of Flight Detector. The mechanical structure meets the requirements of minimizing the material budget and be free of ferromagnetic materials, without compromising its robustness. The design also allows for easy module replacement for maintenance and overall removal at the end of the first stage of the experiment, without affecting the rest of the subsystems, to leave room for the installation of the Inner Tracking System. In addition, a Finite Element Method analysis of the mechanical components under load was performed. Based on this analysis, it was determined that the design meets the space constraints within the Multi-Purpose Detector, as well as a deformation of less than 1 mm with overall stress of less than 2 MPa, such that no material used in the design is at risk of mechanical failure during operation. The heat transfer analysis of the cooling system revealed that the temperature of the cooling plate is maintained within a range of $19.00^{\circ}$C to $21.41^{\circ}$C, which is sufficient to ensure that the silicon photomultipliers operate below a temperature of 25.00$^{\circ}$C, thereby optimizing their functionality

physics.ins-det

A beam-beam monitoring detector for the MPD experiment at NICA

The Multi-Purpose Detector (MPD) is to be installed at the Nuclotron Ion Collider fAcility (NICA) of the Joint Institute for Nuclear Research (JINR). Its main goal is to study the phase diagram of the strongly interacting matter produced in heavy-ion collisions. These studies, while providing insight into the physics of heavy-ion collisions, are relevant for improving our understanding of the evolution of the early Universe and the formation of neutron stars. In order to extend the MPD trigger capabilities, we propose to include a high granularity beam-beam monitoring detector (BE-BE) to provide a level-0 trigger signal with an expected time resolution of 30 ps. This new detector will improve the determination of the reaction plane by the MPD experiment, a key measurement for flow studies that provides physics insight into the early stages of the reaction. In this work, we use simulated Au+Au collisions at NICA energies to show the potential of such a detector to determine the event plane resolution, providing further redundancy to the detectors originally considered for this purpose namely, the Fast Forward Detector (FFD) and the Hadron Calorimeter (HCAL). We also show our results for the time resolution studies of two prototype cells carried out at the T10 beam line at the CERN PS complex.

physics.ins-det

Time resolution studies for scintillating plastics coupled to silicon photo-multipliers

We present results for time resolution studies performed on three different scintillating plastics and two silicon photo-multipliers. These studies are intended to determine whether scintillating plastic/silicon photo-multiplier systems can be employed to provide a fast trigger signal for NICA's Multi Purpose Detector (MPD). Our results show that such a system made of cells with transverse dimensions of order of a few cm, coupled to silicon photo-multipliers, provides a time resolution of about 50 ps, which can be even further improved to attain the MPD trigger requirements of 20 ps.

physics.ins-det