Publications and source records attributed to Maxim Zaitsev.

10 recordsLinked to original sources

Vendor-Agnostic Joint Relaxometry and Myelin Water Fraction Mapping with B1 and Motion Correction

Obtaining consistent quantitative maps of myelin content and relaxation times across different sites and vendors is essential for advancing our understanding of brain development. Herein, we present a harmonized, vendor-agnostic magnetic resonance acquisition method designed for joint T1, T2, and myelin water fraction mapping, along with a method for rapid B1+ and B1- field estimation. We used our dictionary-based fitting and multi-compartment modeling for joint mapping of T1, T2 and myelin water fraction. Self-navigation-based retrospective motion correction was integrated with subspace reconstruction to track and correct rigid head motion during scanning, operating without the need for external hardware. Simulations, phantom and in vivo experiments confirmed the sensitivity and accuracy of the method, particularly for short T2 values corresponding to myelin, and demonstrated consistent performance across multiple scanner types. Coupled with the harmonized calibration scan, the proposed package offers a practical tool for multi-site, multi-vendor neuroimaging studies in both adult and pediatric populations.

physics.med-ph

Bilateral breast gradient insert prototype for strong diffusion encoding at 3T

Purpose: Diffusion MRI has shown promise for breast cancer screening, lesion characterization,and treatment response monitoring without contrast agents, but further translation is constraint by the gradient performance of conventional systems. The aim of this work is to develop a single-axis high performance bilateral plug-and-play breast gradient insert to enable strong-gradient diffusion MRI. Methods: An in-house breast gradient insert and bed-tabletop was constructed entirely from commercially available materials, providing a cost-effective solution compatible with existing MRI systems. Its wiring pattern was optimized for torque and force balancing, power dissipation, and target field performance. Evaluation included gradient field characterization, peripheral nerve stimulation simulation verification, and temperature and eddy current assessment. The setup was used for imaging of a diffusion phantom based on soy lecithin across a range of b-values. Results: Gradient efficiency reached 2.8 mT/m/A, enabling local strengths up to 1850 mT/m (660 A). No peripheral nerve stimulation was observed during tests on five healthy volunteers. Eddy currents were successfully characterized employed in standard correction methods. Imaging showed the feasibility of $b = 10 000 s/mm^2$ acquisitions at TE = 78 ms versus 161 ms with scanner gradients. Conclusion: This work demonstrates a dedicated bilateral breast gradient insert for safe and feasible strong-gradient breast diffusion MRI, and represents a first step toward dedicated hardware for breast cancer detection and characterization without contrast agents.

physics.med-ph

OpenMRF: A Modular, Vendor-Neutral Open-Source Framework for Reproducible Magnetic Resonance Fingerprinting using Pulseq

Purpose: Widespread adoption and methodological advancement of Magnetic Resonance Fingerprinting (MRF) are limited by the lack of unified, reproducible implementation frameworks and fragmented open-source tools. To address these barriers, we introduce OpenMRF - a comprehensive Pulseq-based solution - designed to enable consistent, reproducible, and transferable MRF research across vendors, sites, and field strengths. Methods: OpenMRF integrates modular Pulseq-based sequence design, Bloch-simulation-based dictionary creation directly from .seq files, and iterative low-rank subspace reconstruction. The framework was evaluated through digital phantom simulations, a multi-site ISMRM/NIST phantom study on Siemens MRI systems at 0.55 T, 1.5 T, and 3 T as well as GE and United Imaging 3 T platforms, and representative in vivo acquisitions in the liver (0.55 T), myocardium (1.5 T), and brain (3 T). Results: Simulations demonstrated high mapping accuracy in an ISMRM/NIST-like digital phantom, with low-rank reconstruction yielding deviations of 0.03+/-0.32 % (T1) and 0.12+/-1.94 % (T2). The multi-site phantom study yielded relaxation times consistent with reference values at all field strengths, with mean deviations of -0.1+/-2.9 % (T1), -1.5+/-8.7 % (T2), and -4.0+/-7.2 % (T1rho). In vivo acquisitions produced high-quality parameter maps across platforms and field strengths. Conclusion: OpenMRF provides a robust, open-source, end-to-end Pulseq-based solution for MRF that enables reproducible sequence implementation, physics-accurate dictionary simulation, and advanced reconstruction across vendors and field strengths. By providing a unified platform for method development, comparison, and multi-site validation, OpenMRF aims to accelerate reproducible and harmonized quantitative MRI research within the community.

physics.med-ph

Design of a double breast gradient coil with controlled anterior posterior gradient variation for diffusion weighted imaging

Introduction High performance gradients poses a promise for breast diffusion weighted imaging (DWI) but are restricted by physiological limits in whole body scanners. While local nonlinear coils offer higher amplitudes, they often suffer from severe gradient reduction near the chest wall. Methods We introduced an optimization framework incorporating a constraint to control anterior posterior gradient variation. A width based figure of merit was defined to evaluate performance regarding coil efficiency and minimum wire width. A prototype was constructed to validate the design methodology. Results The optimized coil achieved a 2.35 fold efficiency increase over standard linear coils. Compared to previous nonlinear designs, the new constraint reduced spatial variation by 35.7% and improved minimum efficiency near the chest wall by 2.6 fold. Experimental field maps matched simulations with errors under 8%. Discussion The proposed method effectively mitigates the trade-off between gradient strength and spatial uniformity along anterior posterior direction. By enhancing performance in the posterior breast region, the design addresses a critical limitation of previous local coils. Conclusion This framework enables the development of high performance, robust local gradient coils, facilitating the clinical implementation of advanced DWI protocols for breast cancer screening.

physics.med-ph

Prediction of Local Failure after Stereotactic Radiotherapy in Melanoma Brain Metastases Using Ensemble Learning on Clinical, Dosimetric, and Radiomic Data

Background: This study aimed to predict lesion-specific outcomes after stereotactic radiotherapy (SRT) in patients with brain metastases from malignant melanoma (MBM), using clinical, dosimetric, and pretherapeutic MRI data. Methods: In this multicenter retrospective study, 517 MBM from 130 patients treated with single-fraction or hypofractionated SRT at three centers were analyzed. From contrast-enhanced T1-weighted MRI, 1576 radiomic features (RF) were extracted per lesion - 788 from the gross tumor volume (GTV) and 788 from a 3 mm peritumoral margin. Clinical, dosimetric and RF data from one center were used for feature selection and model development via nested cross-validation employing an ensemble learning approach; external validation used data from the other two centers. Results: Local failure occurred in 72/517 lesions (13.9%). Predictive models based on clinical data, RF, or a combination of both achieved c-indices of 0.60 +/- 0.15, 0.65 +/- 0.11, and 0.65 +/- 0.12, respectively. RF-based models outperformed the clinical models; dosimetric data alone were not predictive. Most predictive RF originated from the peritumoral margin (92%) versus GTV (76%). On the first external dataset, all models performed similarly (c-index: 0.60-0.63), but generalization was poor on the second (c-index < 0.50), likely due to differences in patient characteristics and imaging protocols. Conclusions: Pretherapeutic MRI features, particularly from the peritumoral region, show promise for predicting lesion-specific outcomes in MBM after SRT. Their consistent contribution suggests biologically relevant information that may support individualized treatment planning. Combined with clinical data, these markers offer prognostic insight, though generalizability remains limited by data heterogeneity.

physics.med-ph

Predicting dynamic, motion-related changes in B0 field in the brain at a 7 T MRI using a subject-specific fine-tuned U-net

Subject movement during the magnetic resonance examination is inevitable and causes not only image artefacts but also deteriorates the homogeneity of the main magnetic field (B0), which is a prerequisite for high quality data. Thus, characterization of changes to B0, e.g. induced by patient movement, is important for MR applications that are prone to B0 inhomogeneities. We propose a deep learning based method to predict such changes within the brain from the change of the head position to facilitate retrospective or even real-time correction. A 3D U-net was trained on in vivo brain 7T MRI data. The input consisted of B0 maps and anatomical images at an initial position, and anatomical images at a different head position (obtained by applying a rigid-body transformation on the initial anatomical image). The output consisted of B0 maps at the new head positions. We further fine-tuned the network weights to each subject by measuring a limited number of head positions of the given subject, and trained the U-net with these data. Our approach was compared to established dynamic B0 field mapping via interleaved navigators, which suffer from limited spatial resolution and the need for undesirable sequence modifications. Qualitative and quantitative comparison showed similar performance between an interleaved navigator-equivalent method and proposed method. We therefore conclude that it is feasible to predict B0 maps from rigid subject movement and, when combined with external tracking hardware, this information could be used to improve the quality of magnetic resonance acquisitions without the use of navigators.

cs.CV

Prediction of motion induced magnetic fields for human brain MRI at 3T

Objective Maps of B0 field inhomogeneities are often used to improve MRI image quality, even in a retrospective fashion. These field inhomogeneities depend on the exact head position within the static field but acquiring field maps (FM) at every position is time consuming. Here we explore different ways to obtain B0 predictions at different head positions. Methods FM were predicted from iterative simulations with four field factors: 1) sample induced B0 field, 2) system's spherical harmonic shim field, 3) perturbing field originating outside the field of view, 4) sequence phase errors. The simulation was improved by including local susceptibility sources estimated from UTE scans and position-specific masks. The estimation performance of the simulated FMs and a transformed FM, obtained from the measured reference FM, were compared with the actual FM at different head positions. Results The transformed FM provided inconsistent results for large head movements (>5 degree rotation), while the simulation strategy had a superior prediction accuracy for all positions. The simulated FM was used to optimize B0 shims with up to 22.2% improvement with respect to the transformed FM approach. Conclusion The proposed simulation strategy is able to predict movement induced B0 field inhomogeneities yielding more precise estimates of the ground truth field homogeneity than the transformed FM.

physics.med-ph

Single Shot Spiral TSE with Annulated Segmentation

Purpose: To develop, optimize and implement a single shot spiral TSE-sequence at 3 T and to demonstrate its feasibility to acquire artefact free images of the central nervous system with 1 mm spatial resolution in < 200 ms. Theory and Methods: Spiral TSE sequences with annulated spiral segmentation have been implemented with different acquisition modes. In fixed mode the duration of each spiral segment is fixed to fill the available acquisition time tacq. In tangential mode, the beginning of each spiral segment is reached via a straight tangential trajectory. Tangential mode allows faster transition and thus longer tacq for a given echo spacing ESP, but less data points can be acquired per acquisition interval. Alternating between spiral-in and spiral-out readout in alternating echoes leads to a somewhat different point spread function for off-resonant spins. Results: Images of the brain with 1 mm spatial resolution acquired with a variable density spiral with ~45 % undersampling can be acquired in a single shot. All acquisition modes produce comparable image quality. Only mild artifacts in regions of strong susceptibility effects can be observed for ESP of 10 ms and below. The use of variable flip angle schemes allows seamless acquisition of consecutive slices and/or dynamic scans without waiting time between consecutive acquisitions. Comparison with images acquired at 1.5 T shows reduced susceptibility artifacts within the brain and facial structures.. Conclusion: Single shot spiral TSE has been demonstrated to enable highly efficient acquisition of high-resolution images of the brain in < 200 ms per slice.

physics.med-ph

Design of a non-linear human breast diffusion coil

Diffusion-weighted imaging (DWI) in the female breast is a magnetic resonance imaging (MRI) technique, which may potentially replace or effectively complement both x-ray mammography and contrast-enhanced MR mammography. To further improve specificity of DWI in the breast, stronger and faster diffusion weighting is advantageous. With the target application in mind, the gradient coil is designed on an irregularly shaped semi-open current-carrying surface. Due to the coil former closely fitting the non-spherical target region, non-linear encoding fields become particularly advantageous for achieving locally exceptionally high gradient strengths. As the breast tissue has a predominantly isotropic cellular microstructure, the direction of the diffusion-weighting gradient may be allowed to vary within the target volume. However, due to the quadratic dependency of the b-factor on the gradient strength, variation of the gradient magnitude needs to be carefully controlled. To achieve the above design goals the corresponding multi-objective optimization problem is reformulated as a constrained optimization, allowing for flexible and precise control of the coil properties. A novel constraint is proposed limiting the gradient magnitude variation within every slice while allowing for variations both the direction of the gradient within the slice and the magnitude across the slices. The above innovations enable the design of a unilateral coil for diffusion weighting in the female breast with the local gradient strengths exceeding 1~T/m with highly homogeneous diffusion weighting for imaging in the coronal slice orientation.

physics.med-ph

Magnetic properties of materials for MR engineering, micro-MR and beyond

We present the results of a systematic measurement of the magnetic susceptibility of small material samples in a 9.4 T MRI scanner. We measured many of the most widely used materials in MR engineering and MR micro technology, including various polymers, optical and substrate glasses, resins, glues, photoresists, PCB substrates and some fluids. Based on our data, we identify particularly suitable materials with susceptibilities close to water. For polyurethane resins and elastomers, we also show the MR spectra, as they may be a good substitute for silicone elastomers and good casting resins.

cond-mat.mtrl-sci