Searcharxiv⌕ Search

arXiv subjects

Maxime Boy-Arnould

Publications and source records attributed to Maxime Boy-Arnould.

4 recordsLinked to original sources

Ultrahigh-speed digital holography reveals blood flow beneath the skin

Laser Doppler holography (LDH) leverages ultrahigh-speed digital holography to reveal blood-flow signals in vessels beneath the skin of the closed eyelid and around the eye. We demonstrate this in one volunteer using recordings acquired at approximately 16,000 frames/s under 10~mW of diffuse near-infrared illumination. Numerical Fresnel reconstruction and principal-component filtering reveal branching vascular patterns. These results extend an ocular imaging system to blood-flow visualization beneath the skin without requiring elaborate immobilization procedures.

physics.optics↗

High-speed laser speckle contrast imaging of the human retina

We demonstrate real-time laser speckle contrast imaging of the human retina using a Phantom S980 streaming camera at $3840\times2160$ pixels, 8-bit depth, and 1000 frames per second, with a $988\,μ\mathrm{s}$ exposure. We report four recordings of the peripapillary retina around the optic disc in the right eye of one healthy 25-year-old emmetropic man, acquired without pharmacological pupil dilation, using 852-nm diffuse Maxwellian illumination at an entering optical power of 5.0 mW. Each recording contained 4096 frames (4.10 s), and all 16384 frames in the reported recordings were retained. Open-source Holoflow software on an NVIDIA RTX 5090 computes $K=σ/μ$ over $5\times5$ spatial pixels and nonoverlapping blocks of 16 frames, producing 62.5 contrast maps/s with 60-frame/s rendering and no additional averaging. The nominal raw-input throughput is 8.29 Gpixel/s. Main retinal arterial and venous branches and smaller peripapillary vessels were visualized. Variations during the cardiac cycle were visible in the principal retinal arteries and veins, as illustrated in the Supplementary Videos. Regional inverse-contrast traces show an arterial dicrotic notch and spontaneous venous pulsation. This single-volunteer demonstration establishes an operating point for high-throughput retinal speckle-contrast visualization. Physiological observations are descriptive; contrast is an instrument-dependent observable rather than a calibrated blood-flow velocity.

physics.optics↗

Holovibes: real-time ultrahigh-speed digital hologram rendering and short-time analysis

Real-time ultrahigh-speed rendering of digital holograms from high-bitrate interferogram streams demands robust parallel computing and efficient data handling with minimal latency. We present Holovibes, a high-performance software engine that enables real-time holographic image reconstruction and short-time analysis at unprecedented throughput. Holovibes integrates spatial demodulation techniques, such as Fresnel transformations and angular spectrum propagation, with temporal analysis methods including short-time Fourier transform (STFT) and principal component analysis (PCA) in a unified pipeline. By leveraging CUDA-based GPU acceleration, multithreaded parallelism, and efficient buffering, the system achieves high-throughput, low-latency processing suitable for demanding computational imaging applications. We demonstrate sustained real-time hologram rendering of 256x256-pixel from interferograms acquired by a streaming camera at 71,400 frames per second on commodity hardware with no frame loss, while maintaining an end-to-end latency of 30 ms. The engine also supports simultaneous recording of raw or processed data, enabling high-speed acquisition workflows essential for experimental applications. This work represents a significant advance over prior digital holography systems and provides a versatile platform for ultra-high-speed, real-time computational imaging.

physics.optics↗

Retinal arterial blood flow measured by real-time Doppler holography at 33,000 frames per second

This study presents a novel quantitative estimation method for total retinal arterial blood flow utilizing real-time Doppler holography at an unprecedented frame rate of 33,000 frames per second. This technique, leveraging high-speed digital holography, enables non-invasive angiographic imaging of the retina, providing detailed blood flow contrasts essential for assessing retinal health. The proposed quantitative analysis method consists of segmenting primary in-plane retinal arteries and calculating local blood velocity using Doppler frequency broadening. The analysis integrates a forward scattering model to achieve blood flow estimation. Our findings highlight the potential of Doppler holography as a powerful tool for diagnosing and monitoring the treatment of retinal vascular conditions, complementary to existing imaging methods.

eess.IV↗