SearcharxivSearch

arXiv subjects

Maxime Cannesson

Publications and source records attributed to Maxime Cannesson.

3 recordsLinked to original sources

HIPNO: Symmetry-Aware Physics-Informed Neural Operators for Noninvasive Hemodynamic Inference

Continuous hemodynamic monitoring guides treatment decisions in surgery and intensive care. However, gold-standard signals are only measured in severe cases due to risks associated with invasive measurement. In this work, we introduce HIPNO (Hemodynamic Inference via Physics-informed Neural Operators) to recover hemodynamic state from ubiquitous, non-invasive signals and expand access to advanced monitoring. HIPNO addresses a problem of scale symmetry in physics-informed hemodynamic inference, where different combinations of flow, resistance, and compliance can generate the same observed pressure. We identify the symmetry group of the observation model and parameterize the network in its quotient space. For the 3-element Windkessel model, the quotient coordinates are the compliance-normalized flow $U=Q/C$, the decay time constant $\tau_{WK}=R_2 C$, and the characteristic-impedance coordinate $\kappa=R_1 C$. Across 945499 intraoperative windows from 2562 patients, HIPNO predicts $\tau_{wave}$, a proxy for vascular decay derived from pressure, with 32% lower error on the log scale than a population baseline while preserving mean arterial pressure accuracy. Because vascular decay and flow drive occupy separate coordinates, counterfactual perturbations produce the expected directional responses in at least 90% of windows in almost all prespecified scenarios, a separation unavailable to pressure-only baselines. The coordinates are also used as inputs to a calibration model for monitored cardiac output. Finally, the formulation identifies the external compliance or flow reference required to recover absolute physical scale.

q-bio.QM

Learning Matching Representations for Individualized Organ Transplantation Allocation

Organ transplantation is often the last resort for treating end-stage illness, but the probability of a successful transplantation depends greatly on compatibility between donors and recipients. Current medical practice relies on coarse rules for donor-recipient matching, but is short of domain knowledge regarding the complex factors underlying organ compatibility. In this paper, we formulate the problem of learning data-driven rules for organ matching using observational data for organ allocations and transplant outcomes. This problem departs from the standard supervised learning setup in that it involves matching the two feature spaces (i.e., donors and recipients), and requires estimating transplant outcomes under counterfactual matches not observed in the data. To address these problems, we propose a model based on representation learning to predict donor-recipient compatibility; our model learns representations that cluster donor features, and applies donor-invariant transformations to recipient features to predict outcomes for a given donor-recipient feature instance. Experiments on semi-synthetic and real-world datasets show that our model outperforms state-of-art allocation methods and policies executed by human experts.

stat.ML

Diverse R-PPG: Camera-Based Heart Rate Estimation for Diverse Subject Skin-Tones and Scenes

Heart rate (HR) is an essential clinical measure for the assessment of cardiorespiratory instability. Since communities of color are disproportionately affected by both COVID-19 and cardiovascular disease, there is a pressing need to deploy contactless HR sensing solutions for high-quality telemedicine evaluations. Existing computer vision methods that estimate HR from facial videos exhibit biased performance against dark skin tones. We present a novel physics-driven algorithm that boosts performance on darker skin tones in our reported data. We assess the performance of our method through the creation of the first telemedicine-focused remote vital signs dataset, the VITAL dataset. 432 videos (~864 minutes) of 54 subjects with diverse skin tones are recorded under realistic scene conditions with corresponding vital sign data. Our method reduces errors due to lighting changes, shadows, and specular highlights and imparts unbiased performance gains across skin tones, setting the stage for making medically inclusive non-contact HR sensing technologies a viable reality for patients of all skin tones.

eess.IV